Displaying Product 301 - 400 of 458 in total
Request For Quote | Model # | Type | Total Outlets | Power Capacity kW | Voltage | Current (A) | Current Rated (A) | Phase | Plug Type | Description | Branch Monitoring | Outlet Monitoring | Dimensions | Mounting | PRO2 | Input Monitoring | Alt Phase |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
STV-4511K | Switched | 48 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | PRO2 Switched PDU with PIPS... | Current (A) | None | 0U Vertical | PIPS | false | |||
CB-26V0AE01F6 | Basic | 26 | 3.6 | 208 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-240V Inlet | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | false | |||
C1W16HR-1ACA5BA5 | Switched | 16 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Switched PRO1, Per Input Po... | None | None | 2U Horizontal | PIPS | false | |||
C1W16HR-1DCA5BA5 | Switched | 16 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Switched PRO1, Per Input Po... | None | None | 2U Horizontal | PIPS | false | |||
C1W08HC-0ABA2BAC | Switched | 8 | 3.3 | 208 | 16 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched PRO1, 1U, 8 x IEC ... | Sense | None | 1U Horizontal | PIPS | false | |||
C1W08HC-2CBA2BAC | Switched | 8 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1, 1U, 8 x IEC ... | Sense | None | 1U Horizontal | PIPS | false | |||
C1W08HC-EPBA2BAC | Switched | 8 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO1, 1U, 8 x IEC ... | Sense | None | 1U Horizontal | PIPS | false | |||
C1S24VS-5PFA11F2 | Smart | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Smart PRO1, 0U, 18 x IEC C1... | None | None | 0U Vertical | Current (A) | false | |||
STV-4540K | Switched | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
C1S24VS-4PFA11F2 | Smart | 24 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart PRO1, 0U, 18 x IEC C1... | None | None | 0U Vertical | Current (A) | false | |||
STV-4521Y | Switched | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched PRO2, 0U, (48) IEC... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4521V | Switched | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO2, 0U, (48) IEC... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-3531A | Smart | 30 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
STV-4521D | Switched | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Switched PRO2, 0U, (48) IEC... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-3531D | Smart | 30 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
STV-4501D | Switched | 30 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541A | Switched | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4541D | Switched | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4540A | Switched | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4540D | Switched | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-6501D | Switched POPS | 30 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
C-12H2C211 | Metered | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Metered PDU, 1U, 12 IEC C13... | None | None | 1U Horizontal | Current (A) | false | |||
C-12H1B211E7 | Metered | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Metered PDU, 1U, 12 IEC C13... | None | None | 1U Horizontal | Current (A) | false | |||
C-12HEK211 | Metered | 12 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Metered PDU, 1U, 12 IEC C13... | None | None | 1U Horizontal | Current (A) | false | |||
C1W24VT-5BPA15AC | Switched | 24 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
C1W08HC-1ACA2BA5 | Switched | 8 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Switched PRO1, PIPS (Per In... | Sense | None | 1U Horizontal | PIPS | false | |||
C1W08HC-1DCA2BA5 | Switched | 8 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Switched PRO1, PIPS (Per In... | Sense | None | 1U Horizontal | PIPS | false | |||
C1W16VS-1AFA17A5 | Switched | 16 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Switched PRO1, 0U, 16 x NEM... | Sense | None | 0U Vertical | PIPS | false | |||
C1W16VS-1DFA17A5 | Switched | 16 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Switched PRO1, 0U, 16 x NEM... | Sense | None | 0U Vertical | PIPS | false | |||
C1S15HN-5PJN5BC3-013 | Smart | 15 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Smart PRO1 with PIPS (Per I... | None | None | 2U Horizontal | PIPS | false | |||
STV-3533M | Smart | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | PRO2 Smart Primary PIPS, 0U... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-3533L | Smart | 30 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | PRO2 Smart Primary PIPS, 0U... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-3533E | Smart | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | PRO2 Smart Primary PIPS, 0U... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-3533D | Smart | 30 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | PRO2 Smart Primary PIPS, 0U... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1W24VS-DEFA11AC | Switched | 24 | 12.5 | 208 | 50 | 35 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO1, 0U, (24) IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DBFA11AC | Switched | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched PRO1, 0U, 24 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-YCFA11A0 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 24 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DCFA11AC | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 24 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-YBFA11A0 | Switched | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PRO1, 0U, 24 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W08HC-0A002BAC | Switched | 8 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched PRO1, 1U, 8 x IEC ... | None | None | 1U Horizontal | PIPS | false | |||
STV-6501C | Switched POPS | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6501K | Switched POPS | 30 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6501A | Switched POPS | 30 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-3531J | Smart | 30 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC 230V/16A 2P+PE 6Hr | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
STV-3531B | Smart | 30 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | NEMA L6-20P | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
STV-3531K | Smart | 30 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
STV-4501A | Switched | 30 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4501C | Switched | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6509K | Switched POPS | 36 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-3531G | Smart | 30 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
STV-4501K | Switched | 30 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6502E | Switched POPS | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6502L | Switched POPS | 30 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6509A | Switched POPS | 36 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-20P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6502M | Switched POPS | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6509C | Switched POPS | 36 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6509J | Switched POPS | 36 | 11.1 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6509D | Switched POPS | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
C1S15HN-5CJN5BC3-013 | Smart | 15 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart PRO1 with PIPS (Per I... | None | None | 2U Horizontal | PIPS | false | |||
STV-4502D | Switched | 30 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1S15HN-4PJN5BC3-013 | Smart | 15 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart PRO1 with PIPS (Per I... | None | None | 2U Horizontal | PIPS | false | |||
STV-4502E | Switched | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-3531C | Smart | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart PRO1, PIPS (Per Input... | None | None | 0U Vertical | PIPS | false | |||
C2WG24VT-2CBA1MC1 | Switched POPS | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS PRO2, Per Out... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4502M | Switched | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6509Z | Switched POPS | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6503Z | Switched POPS | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6503D | Switched POPS | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6503K | Switched POPS | 30 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6503J | Switched POPS | 30 | 11.0 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4503J | Switched | 30 | 11.0 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6521V | Switched POPS | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | PRO2 Switched POPS, 0U, 48 ... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4503K | Switched | 30 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4522D | Switched | 48 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6541M | Switched POPS | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | 230V 56 Series 56P332 | Switched POPS PRO2, Per Out... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4503Z | Switched | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4522E | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541K | Switched | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4522L | Switched | 48 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541J | Switched | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC 230V/16A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-5542L | Smart POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | PRO2 Smart POPS PRO2 Primar... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523A | Switched | 48 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-20P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-5542D | Smart POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L15-20P | PRO2 Smart POPS PRO2 Primar... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523C | Switched | 48 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541B | Switched | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | NEMA L6-20P | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-5542E | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L15-30P | PRO2 Smart POPS PRO2 Primar... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523K | Switched | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4540C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4523D | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542M | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS/PIPS PRO2 (Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-5542M | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | PRO2 Smart POPS PRO2 Primar... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4522M | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542L | Switched POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched POPS/PIPS PRO2 (Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523J | Switched | 48 | 11.1 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542E | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS (Per Outlet P... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523Z | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542D | Switched POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched POPS (Per Outlet P... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6521D | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | PRO2 Switched POPS, 0U, 48 ... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6521Y | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | PRO2 Switched POPS, 0U, 48 ... | Current (A) | POPS | 0U Vertical | PIPS | false |