Request For Quote Model # Type Total Outlets Power Capacity kW Voltage Current (A) Current Rated (A) Phase Plug Type Description PDU Platform Outlet Monitoring Dimensions Mounting Branch Monitoring Input Monitoring Alt Phase
STV-6541C Switched POPS 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS PRO2, Per Out... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6543D Switched POPS 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched POPS PRO2, PIPS (P... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6543Z Switched POPS 24 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched POPS PRO2, PIPS (P... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6543K Switched POPS 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Switched POPS PRO2, PIPS (P... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4511A Switched 48 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet PRO2 Switched PDU with PIPS... PRO2 None 0U Vertical Current (A) PIPS false
STV-4511C Switched 48 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P PRO2 Switched PDU with PIPS... PRO2 None 0U Vertical Current (A) PIPS false
STV-4511D Switched 48 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet PRO2 Switched PDU with PIPS... PRO2 None 0U Vertical Current (A) PIPS false
STV-4511K Switched 48 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr PRO2 Switched PDU with PIPS... PRO2 None 0U Vertical Current (A) PIPS false
STV-4521Y Switched 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched PRO2, 0U, (48) IEC... PRO2 None 0U Vertical Current (A) PIPS false
STV-4521V Switched 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO2, 0U, (48) IEC... PRO2 None 0U Vertical Current (A) PIPS false
STV-4521D Switched 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched PRO2, 0U, (48) IEC... PRO2 None 0U Vertical Current (A) PIPS false
STV-4501D Switched 30 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
STV-6501D Switched POPS 30 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-3533M Smart 30 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P PRO2 Smart Primary PIPS, 0U... PRO2 None 0U Vertical Current (A) PIPS false
STV-3533L Smart 30 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P PRO2 Smart Primary PIPS, 0U... PRO2 None 0U Vertical Current (A) PIPS false
STV-3533E Smart 30 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P PRO2 Smart Primary PIPS, 0U... PRO2 None 0U Vertical Current (A) PIPS false
STV-3533D Smart 30 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P PRO2 Smart Primary PIPS, 0U... PRO2 None 0U Vertical Current (A) PIPS false
STV-6501C Switched POPS 30 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6501K Switched POPS 30 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6501A Switched POPS 30 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4501A Switched 30 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
STV-4501C Switched 30 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
STV-4501K Switched 30 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
STV-6502E Switched POPS 30 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6502L Switched POPS 30 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6502M Switched POPS 30 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4502D Switched 30 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
STV-4502E Switched 30 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
C2WG24VT-2CBA1MC1 Switched POPS 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS PRO2, Per Out... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4502M Switched 30 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
STV-6521V Switched POPS 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A PRO2 Switched POPS, 0U, 48 ... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4522D Switched 48 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-6541M Switched POPS 24 7.3 230 32 32 1-Phase (L-N) 230V 56 Series 56P332 Switched POPS PRO2, Per Out... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4522E Switched 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-4522L Switched 48 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-4523A Switched 48 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-4523C Switched 48 11.5 415 20 16 3-Phase Wye (L-N) 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-4523K Switched 48 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-4523D Switched 48 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-6542M Switched POPS 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched POPS/PIPS PRO2 (Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4522M Switched 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-6542L Switched POPS 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched POPS/PIPS PRO2 (Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4523J Switched 48 11.0 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-6542E Switched POPS 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched POPS (Per Outlet P... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4523Z Switched 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-6542D Switched POPS 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched POPS (Per Outlet P... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6521D Switched POPS 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr PRO2 Switched POPS, 0U, 48 ... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-6521Y Switched POPS 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr PRO2 Switched POPS, 0U, 48 ... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4522V Switched 48 10.0 208 30 30 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO2 with PIPS (Pe... PRO2 None 0U Vertical Current (A) PIPS false
STV-4526Y Switched 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched PRO2, 0U, (36) IEC... PRO2 None 0U Vertical Current (A) PIPS false
STV-4526V Switched 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO2, 0U, (36) IEC... PRO2 None 0U Vertical Current (A) PIPS false
STV-4526D Switched 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched PRO2, 0U, (36) IEC... PRO2 None 0U Vertical Current (A) PIPS false
STV-6501M Switched POPS 30 7.3 230 32 32 1-Phase (L-N) 230V 56 Series 56P332 Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4525Z Switched 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO2, 0U, 36xIEC C... PRO2 None 0U Vertical Current (A) PIPS false
STV-4525D Switched 48 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO2, 0U, 36xIEC C... PRO2 None 0U Vertical Current (A) PIPS false
STV-4525J Switched 48 11.0 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Switched PRO2, 0U, 36xIEC C... PRO2 None 0U Vertical Current (A) PIPS false
STV-6501G Switched POPS 30 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched POPS/PIPS PRO2, Pe... PRO2 POPS 0U Vertical Current (A) PIPS false
STV-4502L Switched 30 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PIPS PRO2, Per Inp... PRO2 None 0U Vertical Current (A) PIPS false
C1S10SA-2CBA2B4 Smart 10 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart Primary PRO1 PIPS PDU... PRO1 None 1U Horizontal None PIPS false
C1S10SA-EPBA2B4 Smart 10 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart Primary PRO1 PIPS PDU... PRO1 None 1U Horizontal None PIPS false
C1S24SP-0AAA4A6 Smart 24 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PIPS PRO1, 2U, (18) H... PRO1 None 2U Horizontal None PIPS false
C1S24SP-EPAA4A6 Smart 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PIPS PRO1, 2U, (18) H... PRO1 None 2U Horizontal None PIPS false
C1S24SP-2CAA4A6 Smart 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PIPS PRO1, 2U, (18) H... PRO1 None 2U Horizontal None PIPS false
C1S10SA-0ABA2B4 Smart 10 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary PRO1 PIPS PDU... PRO1 None 1U Horizontal None PIPS false
C1S39TS-5CPD2T444 Smart 39 17.3 415 30 30 3-Phase Wye (L-N) NEMA L22-30P Smart PRO1 Primary PIPS, 39... PRO1 None 0U Vertical None PIPS false
C1S39TS-4PPD2T444 Smart 39 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart PRO1 Primary PIPS, 39... PRO1 None 0U Vertical None PIPS false
C1S13TS-0ABA154 Smart 13 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary Pro1 PIPS Ver... PRO1 None 0U Vertical None PIPS false
C1S13TS-2CBA154 Smart 13 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart Primary Pro1 PIPS Ver... PRO1 None 0U Vertical None PIPS false
C1S13TS-EPBA154 Smart 13 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart Primary Pro1 PIPS Ver... PRO1 None 0U Vertical None PIPS false
C1S13TS-OABA154 Smart 13 1.9 120 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary Pro1 PIPS Ver... PRO1 None 0U Vertical None PIPS false
C1S24TB-4QAE2566 Smart 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Smart Primary PRO1 12xC13 +... PRO1 None 0U Vertical None PIPS true
C1S24TB-4QAE2766 Smart 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Smart Primary PRO1 12xC13 +... PRO1 None 0U Vertical None PIPS true
C1S24TB-5QAE2566 Smart 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Smart Primary PRO1 12xC13 +... PRO1 None 0U Vertical None PIPS true
C1S24TB-5QAE2766 Smart 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Smart Primary PRO1 12xC13 +... PRO1 None 0U Vertical None PIPS true
C1S24BP-0AAA4A6 Smart 24 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PIPS PRO1, 2U, (18) H... PRO1 None 2U Horizontal None PIPS false
C1S24BP-2CAA4A6 Smart 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PIPS PRO1, 2U, (18) H... PRO1 None 2U Horizontal None PIPS false
C1S24BP-EPAA4A6 Smart 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PIPS PRO1, 2U, (18) H... PRO1 None 2U Horizontal None PIPS false
C1S26BP-0AAA4A0 Smart 26 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PIPS PRO1, 2U, (26) H... PRO1 None 2U Horizontal None PIPS false
C1S26BP-EPAA4A0 Smart 26 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PIPS PRO1, 2U, (26) H... PRO1 None 2U Horizontal None PIPS false
C1S42CS-5CPD2T000 Smart 42 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Smart PRO1 Primary PIPS, 42... PRO1 None 0U Vertical None PIPS false
C1S14CS-2CBA150 Smart 14 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart Primary PIPS V14 High... PRO1 None 0U Vertical None PIPS false
C1S13CS-2CBA152 Smart 13 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart Primary Pro1 PIPS V13... PRO1 None 0U Vertical None PIPS false
C1S42CS-4PPD2T000 Smart 42 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart PRO1 Primary PIPS, 42... PRO1 None 0U Vertical None PIPS false
C1S13CS-0ABA152 Smart 13 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary Pro1 PIPS V14... PRO1 None 0U Vertical None PIPS false
C1S39CS-5CPD2T444 Smart 39 17.3 415 30 30 3-Phase Wye (L-N) NEMA L22-30P Smart PRO1 Primary PIPS, 39... PRO1 None 0U Vertical None PIPS false
C1S14CS-EPBA150 Smart 14 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart Primary Pro1 PIPS V14... PRO1 None 0U Vertical None PIPS false
C1S14CS-0ABA150 Smart 14 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary Pro1 PIPS V14... PRO1 None 0U Vertical None PIPS false
C1S39CS-4PPD2T444 Smart 39 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart PRO1 Primary PIPS, 39... PRO1 None 0U Vertical None PIPS false
C1S13CS-EPBA152 Smart 13 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart Primary Pro1 PIPS V14... PRO1 None 0U Vertical None PIPS false
C1S24CB-4QAE2766 Smart 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Smart Primary PRO1 12xC13+1... PRO1 None 0U Vertical None PIPS true
C1S24CB-4QAE2566 Smart 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Smart Primary PRO1 12xC13+1... PRO1 None 0U Vertical None PIPS true
C1S24CB-5QAE2500 Smart 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Smart Primary PRO1 24xC13 A... PRO1 None 0U Vertical None PIPS true
C1S24CB-4QAE2500 Smart 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Smart Primary PRO1 24xC13 A... PRO1 None 0U Vertical None PIPS true
C1S24CB-4QAE2700 Smart 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Smart Primary PRO1 24xC13 A... PRO1 None 0U Vertical None PIPS true
C1S24CB-5QAE2700 Smart 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Smart Primary PRO1 24xC13 A... PRO1 None 0U Vertical None PIPS true
C1S24CB-5QAE2566 Smart 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Smart Primary PRO1 12xC13 +... PRO1 None 0U Vertical None PIPS true
C1S24CB-5QAE2766 Smart 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr Smart Primary PRO1 12xC13 +... PRO1 None 0U Vertical None PIPS true
C1S36CA-YQME2766 Smart 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr PRO1 Smart Primary PIPS V36... PRO1 None 0U Vertical Sense PIPS true
C1S36CA-DFME2766 Smart 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A PRO1 Smart Primary PIPS V36... PRO1 None 0U Vertical Sense PIPS true
C1S42CA-YQME2700 Smart 42 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr PRO1 Smart Primary PIPS (42... PRO1 None 0U Vertical Sense PIPS true