| Request For Quote | Model # | Type | Total Outlets | Power Capacity kW | Voltage | Current (A) | Current Rated (A) | Phase | Plug Type | Description | PDU Platform | Outlet Monitoring | Dimensions | Mounting | Branch Monitoring | Input Monitoring | Alt Phase |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| C2W48TE-DFME2M99 | Switched | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched Primary PRO2 30xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W48TE-YQME2M99 | Switched | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched Primary PRO2 30xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2WG48TE-DFME2M99 | Switched POPS | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2WG48TE-YQME2M99 | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2WG24SN-DCLN5D6 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-EPJN5D6 | Switched POPS | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG12SM-0AJA2D3 | Switched POPS | 12 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched POPS PRO2, 1U, (12... | PRO2 | POPS | 1U Horizontal | Current (A) | PIPS | false | ||
| C2WG12SM-EPJA2D3 | Switched POPS | 12 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched POPS PRO2, 1U, (12... | PRO2 | POPS | 1U Horizontal | Current (A) | PIPS | false | ||
| C2WG12SM-2CJA2D3 | Switched POPS | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS PRO2, 1U, 12 ... | PRO2 | POPS | 1U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-2CJN5D6 | Switched POPS | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-YCLN5D6 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-4NJN5D6 | Switched POPS | 24 | 11.0 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-5PJN5D6 | Switched POPS | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-4PJN5D6 | Switched POPS | 24 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-0AJN5D6 | Switched POPS | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-YBLN5D6 | Switched POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24SN-5CJN5D6 | Switched POPS | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG48TE-5PAE2M99 | Switched POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S48TE-5PAE2M99 | Smart | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Smart Primary PRO2 (30xC13 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2WG48TE-DQME2M99 | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2SG48TE-DQME2M99 | Smart POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Smart POPS Primary PRO2 30x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2WG24TB-4QCD27T0 | Switched POPS | 24 | 43.4 | 400 | 63 | 63 | 3-Phase Wye (L-N) | 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr | Switched PRO2 POPS PIPS PDU... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
| C2WG24TB-5QCD27T0 | Switched POPS | 24 | 34.5 | 415 | 60 | 48 | 3-Phase Wye (L-N) | 240/415V Wye 60A IEC 60309 3P+N+G 6Hr | **Custom** Switched PRO2 PO... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | true | ||
| C2W36TE-DQME2M99 | Switched | 36 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Switched Primary PRO2 18xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S42CE-DCMFAM00 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S42CE-YQME2M00 | Smart | 42 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S42CE-DFME2M00 | Smart | 42 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S42CE-YCMFAM00 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2SG36CE-DCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2SG36CE-DFME2M66 | Smart POPS | 36 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2SG36CE-YCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2SG36CE-YQME2M66 | Smart POPS | 36 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-YCMFAM00 | Switched | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-DCMFAM00 | Switched | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2, Per Input Po... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-DFME2M00 | Switched | 42 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PIPS PRO2, Per Inp... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-YQME2M00 | Switched | 42 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-2CAF2M00 | Switched | 42 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2W42CE-2QAF2M00 | Switched | 42 | 10.0 | 208 | 60 | 48 | 1-Phase (L-L) | IEC 208V/60A 2P+G 6Hr | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2S42CE-2CAF2M00 | Smart | 42 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2SG36CE-EQAF2M66 | Smart POPS | 36 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Smart POPS Primary PRO2 (36... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2W42CE-EQAF2M00 | Switched | 42 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2S42CE-EPAF2M00 | Smart | 42 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2S42CE-EQAF2M00 | Smart | 42 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2W42CE-EPAF2M00 | Switched | 42 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2S42CE-2QAF2M00 | Smart | 42 | 10.0 | 208 | 60 | 48 | 1-Phase (L-L) | IEC 208V/60A 2P+G 6Hr | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
| C2WG24BN-DCLN5D0 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2WG24BN-YCLN5D0 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
| C2S42CE-4PAE2M00 | Smart | 42 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S42CE-5CAE2M00 | Smart | 42 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W36CE-5CAE2M66 | Switched | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Primary PRO2 24xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-4PAE2M00 | Switched | 42 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W42CE-5CAE2M00 | Switched | 42 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W54CE-DCMFAM00 | Switched | 54 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched Primary PRO2 (54)C... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S54CE-DFME2M00 | Smart | 54 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart Primary PRO2 54xC13 A... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S54CE-DQME2M00 | Smart | 54 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Smart Primary PRO2 54xC13 A... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2S54CE-YQME2M00 | Smart | 54 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart Primary PRO2 54xC13 A... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W54CE-DFME2M00 | Switched | 54 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched Primary PRO2 54xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W54CE-DQME2M00 | Switched | 54 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Switched Primary PRO2 54xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| C2W54CE-YQME2M00 | Switched | 54 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched Primary PRO2 54xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
| STV-4523A | Switched | 48 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-20P | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
| STV-4523C | Switched | 48 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
| STV-4523K | Switched | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
| STV-4523D | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
| STV-4523J | Switched | 48 | 11.0 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
| STV-4523Z | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
| CB-12H1-C20 | Basic | 12 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Basic PDU, 12 NEMA 5-20R ou... | None | None | 1U Horizontal | None | None | false | ||
| CB-12H2-L630 | Basic | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Basic PDU, 12 IEC C13 outle... | None | None | 1U Horizontal | None | None | false | ||
| CB-12H2-C20 | Basic | 12 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Basic PDU, 12 IEC C13 outle... | None | None | 1U Horizontal | None | None | false | ||
| CB-12H1-L530 | Basic | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Basic PDU, 12 NEMA 5-20R ou... | None | None | 1U Horizontal | None | None | false | ||
| PTTS-H008-0-02M | FSTS | 8 | 3.3 | 208 | 16 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Sentry Fail Safe Transfer S... | None | None | 1U Horizontal | None | None | false | ||
| CB-26VEKE01F6 | Basic | 26 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | None | false | ||
| CB-26V2CE01F6 | Basic | 26 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | None | false | ||
| CB-26V0AE01F6 | Basic | 26 | 3.6 | 208 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-240V Inlet | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | None | false | ||
| PTTS-H008-O-02M | FSTS | 8 | 1.9 | 120 | 16 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Sentry Fail Safe Transfer S... | None | None | 1U Horizontal | None | None | false | ||
| CB-26VOAE01F6 | Basic | 26 | 1.9 | 120 | 16 | 16 | 1-Phase (L-N) | IEC C20 100-240V Inlet | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | None | false | ||
| STV-3507M | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PRO1 with PIPS (Per I... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
| C1W24VT-4PPA15AC | Switched | 24 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-4NPA15AC | Switched | 24 | 11.1 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-5PPA15AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-5CPA15AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-5NPA15AC | Switched | 24 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VS-DEFA11AC | Switched | 24 | 12.5 | 208 | 50 | 35 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO1, 0U, (24) IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
| C1W24VS-DBFA11AC | Switched | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched PRO1, 0U, 24 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
| C1W24VS-YCFA11A0 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 24 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
| C1W24VS-DCFA11AC | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 24 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
| C1W24VS-YBFA11A0 | Switched | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PRO1, 0U, 24 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
| STV-4541K | Switched | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| STV-4541J | Switched | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC 230V/16A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| STV-4541C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| STV-4541B | Switched | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | NEMA L6-20P | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-5PPA17AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-5CPA17AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| STV-4541A | Switched | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| STV-4541D | Switched | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1W24VT-5BPA15AC | Switched | 24 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| STV-3507L | Smart | 42 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Smart PRO1 with PIPS (Per I... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
| C1W24VT-45PA15AC | Switched | 24 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V 56 Series 56P532 | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
| C1S15HN-YQJN5BC3-013 | Smart | 15 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart PRO1 with PIPS (Per I... | PRO1 | None | 2U Horizontal | None | PIPS | false | ||
| C1S15HN-DQJN5BC3-013 | Smart | 15 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Smart PRO1 with PIPS (Per I... | PRO1 | None | 2U Horizontal | None | PIPS | false | ||
| C1S15HN-DFJN5BC3-013 | Smart | 15 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart PRO1 with PIPS (Per I... | PRO1 | None | 2U Horizontal | None | PIPS | false |