Rack PDU Selector
Displaying Product 1 - 100 of 196 in total
Request For Quote | Model # | Type | Total Outlets | Power Capacity kW | Voltage | Current (A) | Current Rated (A) | Phase | Plug Type | Description | PDU Platform | Outlet Monitoring | Dimensions | Mounting | Branch Monitoring | Input Monitoring | Alt Phase |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CB-12H2-L630 | Basic | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Basic PDU, 12 IEC C13 outle... | None | None | 1U Horizontal | None | None | false | ||
CB-12H1-L530 | Basic | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Basic PDU, 12 NEMA 5-20R ou... | None | None | 1U Horizontal | None | None | false | ||
STV-2001C | Metered | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Metered PDU, 0U, (24) IEC C... | None | None | 0U Vertical | None | Current (A) | false | ||
STV-6501C | Switched POPS | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS/PIPS PRO2, Pe... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
STV-4501C | Switched | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PIPS PRO2, Per Inp... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
STV-6502E | Switched POPS | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS/PIPS PRO2, Pe... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
STV-6502M | Switched POPS | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS/PIPS PRO2, Pe... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
STV-4502E | Switched | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PIPS PRO2, Per Inp... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
STV-4502M | Switched | 30 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PIPS PRO2, Per Inp... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S42CE-DCMFAM00 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2S42CE-YCMFAM00 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
CB-26V2CE01F6 | Basic | 26 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | None | false | ||
C2SG36CE-DCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2SG36CE-YCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
STV-4522E | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
STV-4523D | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
STV-4522M | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
STV-4523Z | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C1S14CS-2CBA150 | Smart | 14 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PIPS V14 High... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C1S13CS-2CBA152 | Smart | 13 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary Pro1 PIPS V13... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
STV-3507M | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PRO1 with PIPS (Per I... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C2W42CE-YCMFAM00 | Switched | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2W42CE-DCMFAM00 | Switched | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2, Per Input Po... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C1W16HR-2CAA5BAC | Switched | 16 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1, Per Input Po... | PRO1 | None | 2U Horizontal | Sense | PIPS | false | ||
C1W24VT-5PPA15AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
C1W24VT-5CPA15AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
STV-6541C | Switched POPS | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS PRO2, Per Out... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
C1S24VS-YCFA11A0 | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PRO1, 0U, 24 x IEC C1... | PRO1 | None | 0U Vertical | None | Current (A) | false | ||
C1S24VS-DCFA11AC | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart PRO1, 0U, 24 x IEC C1... | PRO1 | None | 0U Vertical | None | Current (A) | false | ||
C1S24VS-YCFA13A0 | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PRO1, 0U, 24 x IEC C1... | PRO1 | None | 0U Vertical | None | Current (A) | false | ||
C1S24VS-DCFA13AC | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart PRO1, 0U, 24 x IEC C1... | PRO1 | None | 0U Vertical | None | Current (A) | false | ||
C2S24HP-DCLN5D0 | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart PIPS PRO2 Primary, 2U... | PRO2 | None | 2U Horizontal | Current (A) | PIPS | true | ||
C2S24HP-YCLN5D0 | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PIPS PRO2 Primary, 2U... | PRO2 | None | 2U Horizontal | Current (A) | PIPS | true | ||
C2W42CE-2CAF2M00 | Switched | 42 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
C2S42CE-2CAF2M00 | Smart | 42 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
C-12H1B211E7 | Metered | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Metered PDU, 1U, 12 IEC C13... | None | None | 1U Horizontal | None | Current (A) | false | ||
C1W24VS-YCFA11A0 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 24 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
C1W24VS-DCFA11AC | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 24 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
C2WG24BN-DCLN5D0 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
C2WG24BN-YCLN5D0 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 POPS PIPS, 2U... | PRO2 | POPS | 2U Horizontal | Current (A) | PIPS | false | ||
C2S42CE-5CAE2M00 | Smart | 42 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart Primary PRO2 (42) C13... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2W36CE-5CAE2M66 | Switched | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Primary PRO2 24xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
STV-3531C | Smart | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart PRO1, PIPS (Per Input... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C2W42CE-5CAE2M00 | Switched | 42 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Primary PRO2 (42) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
STV-4541C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
STV-4540C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
STV-6542M | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS/PIPS PRO2 (Pe... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
STV-6542E | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS (Per Outlet P... | PRO2 | POPS | 0U Vertical | Current (A) | PIPS | false | ||
STV-4522V | Switched | 48 | 10.0 | 208 | 30 | 30 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO2 with PIPS (Pe... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C1W24VS-YCFA13C9 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 18 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
C1W24VS-YCFA11C9 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 18 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
C1W24VS-DCFA13A1 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 18 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
C1W24VS-DCFA11A1 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 18 x IEC... | PRO1 | None | 0U Vertical | Sense | Current (A) | false | ||
C1W16VS-2CFA17AC | Switched | 16 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
C2S42CS-DCBA2S000 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart PRO2 Primary PIPS, 42... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S42CS-YCBA2S000 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PRO2 Primary PIPS, 42... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S39CS-DCBA2S444 | Smart | 39 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Primary PRO2 PIPS, 39... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S39CS-YCBA2S444 | Smart | 39 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Primary PRO2 PIPS, 39... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C1S42CS-5CPD2T000 | Smart | 42 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart PRO1 Primary PIPS, 42... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C2S39CS-2CBA2S444 | Smart | 39 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PRO2 PIP, 39 ... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S42CS-2CBA2S000 | Smart | 42 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PRO2 PIP, (42... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
STV-3534D | Smart | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | PRO1 Smart Primary PIPS, 0U... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
STV-3534Z | Smart | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | PRO1 Smart Primary PIPS, 0U... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C1W24VS-1DFA25A5 | Switched | 24 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | PRO1 Switched PDU with PIPS... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
C1W24VT-5PPA17AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
C1W24VT-5CPA17AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
C2WG08HC-2CBA2DAC | Switched POPS | 8 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS PRO2, Per Out... | PRO2 | POPS | 1U Horizontal | Current (A) | PIPS | false | ||
STV-4511C | Switched | 48 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | PRO2 Switched PDU with PIPS... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C1W08HC-2CBA2BAC | Switched | 8 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1, 1U, 8 x IEC ... | PRO1 | None | 1U Horizontal | Sense | PIPS | false | ||
C-12H2C211 | Metered | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Metered PDU, 1U, 12 IEC C13... | None | None | 1U Horizontal | None | Current (A) | false | ||
C1W08HC-1DCA2BA5 | Switched | 8 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Switched PRO1, PIPS (Per In... | PRO1 | None | 1U Horizontal | Sense | PIPS | false | ||
C1W16VS-1DFA17A5 | Switched | 16 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Switched PRO1, 0U, 16 x NEM... | PRO1 | None | 0U Vertical | Sense | PIPS | false | ||
C1S24BP-2CAA4A6 | Smart | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart PIPS PRO1, 2U, (18) H... | PRO1 | None | 2U Horizontal | None | PIPS | false | ||
C2W54CE-DCMFAM00 | Switched | 54 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched Primary PRO2 (54)C... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2S48TE-YCMFAM99 | Smart | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Primary PRO2 30xC13 +... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2S48TE-DCMFAM99 | Smart | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Primary PRO2 30xC13 +... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2SG48TE-DCMFAM99 | Smart POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Primary PRO2 30x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2SG48TE-YCMFAM99 | Smart POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Primary PRO2 30x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2W48TE-YCMFAM99 | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched Primary PRO2 30xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2W48TE-DCMFAM99 | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched Primary PRO2 30xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2WG48TE-YCMFAM99 | Switched POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2WG48TE-DCMFAM99 | Switched POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2S48TE-5CAE2M99 | Smart | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart Primary PRO2 30xC13 +... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2SG48TE-5CAE2M99 | Smart POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart POPS Primary PRO2 30x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2W48TE-5CAE2M99 | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Primary PRO2 30xC1... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2WG48TE-5CAE2M99 | Switched POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C1S39TS-5CPD2T444 | Smart | 39 | 17.3 | 415 | 30 | 30 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart PRO1 Primary PIPS, 39... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C2S39TS-2CBA2S444 | Smart | 39 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PRO2 PIP, 39 ... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S39TS-YCBA2S444 | Smart | 39 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Primary PRO2 PIPS, 39... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C2S39TS-DCBA2S444 | Smart | 39 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Primary PRO2 PIPS, 39... | PRO2 | None | 0U Vertical | Current (A) | PIPS | false | ||
C1S13TS-2CBA154 | Smart | 13 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary Pro1 PIPS Ver... | PRO1 | None | 0U Vertical | None | PIPS | false | ||
C2S36TE-2CAF2M99 | Smart | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Primary PRO2 (36) Alt... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
C2SG36TE-2CAF2M66 | Smart POPS | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart POPS Primary PRO2 (36... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
C2W36TE-2CAF2M99 | Switched | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched Primary PRO2 (36) ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
C2WG36TE-2CAF2M66 | Switched POPS | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS Primary PRO2 ... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | false | ||
C2S36TE-DCMFAM99 | Smart | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Primary PRO2 18xC13 +... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2S36TE-YCMFAM99 | Smart | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Primary PRO2 18xC13 +... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2SG36TE-DCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2SG36TE-YCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Primary PRO2 24x... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true | ||
C2W36TE-DCMFAM99 | Switched | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2, Per Input Po... | PRO2 | Determined By Outlet Module | 0U Vertical | Current (A) | PIPS | true |