Rack PDU Selector

  • Product Type

  • Mounting

  • Total Outlets

  • Outlet Form Factor

  • Input Nominal Voltage

  • Input Phase

  • Input Current

  • Input Plug Type

  • Input Power Capacity

  • PDU Platform

  • Input Monitoring

  • Outlet Monitoring

  • Alternating Phase Outlets

  • Branch Monitoring

  • Show Advanced Options
Displaying Product 401 - 500 of 511 in total
Request For Quote Model # Type Total Outlets Power Capacity kW Voltage Current (A) Current Rated (A) Phase Plug Type Description PDU Platform Outlet Monitoring Dimensions Mounting Branch Monitoring Input Monitoring Alt Phase
C1S42CA-DQME2700 Smart 42 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr PRO1 Smart Primary PIPS (42... PRO1 None 0U Vertical Sense PIPS true
C1S42CA-DFME2700 Smart 42 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A PRO1 Smart Primary PIPS (42... PRO1 None 0U Vertical Sense PIPS true
C1S36CA-DQME2766 Smart 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr PRO1 Smart Primary PIPS (36... PRO1 None 0U Vertical Sense PIPS true
C1S14CS-OABA150 Smart 14 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary Pro1 PIPS V14... PRO1 None 0U Vertical None PIPS false
STV-2001B Metered 30 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Metered PDU, 0U, (24) IEC C... None None 0U Vertical None Current (A) false
C1S24VS-DBFA11AC Smart 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C-12H0A111 Metered 12 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Metered PDU, Horizontal Mou... None None 1U Horizontal None Current (A) false
STV-2001J Metered 30 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Metered PDU, 0U, (24) IEC C... None None 0U Vertical None Current (A) false
C1W16HR-0AAA5BAC Switched 16 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1 with PIPS (Pe... PRO1 None 2U Horizontal Sense PIPS false
C1W16HR-2CAA5BAC Switched 16 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1, Per Input Po... PRO1 None 2U Horizontal Sense PIPS false
C1W24VT-4PPA15AC Switched 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W24VT-4NPA15AC Switched 24 11.1 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W16HR-EPAA5BAC Switched 16 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1, Per Input Po... PRO1 None 2U Horizontal Sense PIPS false
C1W24VT-5PPA15AC Switched 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W24VT-5CPA15AC Switched 24 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W24VT-5NPA15AC Switched 24 11.5 415 20 16 3-Phase Wye (L-N) 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1S24VS-YBFA11A0 Smart 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C1S24VS-YBFA13A0 Smart 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C1W24VT-45PA15AC Switched 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V 56 Series 56P532 Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1S24VS-YCFA11A0 Smart 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C1S24VS-DEFA11AC Smart 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO1, 0U, (24) IEC C1... PRO1 None 0U Vertical None Current (A) false
C1S24VS-DCFA11AC Smart 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C1S24VS-YCFA13A0 Smart 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C1S24VS-DCFA13AC Smart 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO1, 0U, 24 x IEC C1... PRO1 None 0U Vertical None Current (A) false
C1S15HN-YQJN5BC3-013 Smart 15 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart PRO1 with PIPS (Per I... PRO1 None 2U Horizontal None PIPS false
C1S15HN-DQJN5BC3-013 Smart 15 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Smart PRO1 with PIPS (Per I... PRO1 None 2U Horizontal None PIPS false
C1S15HN-DFJN5BC3-013 Smart 15 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO1 with PIPS (Per I... PRO1 None 2U Horizontal None PIPS false
CB-26VEKE01F6 Basic 26 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Basic PDU, (24) IEC C13 + (... None None 0U Vertical None None false
CB-26V2CE01F6 Basic 26 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Basic PDU, (24) IEC C13 + (... None None 0U Vertical None None false
CB-26V0AE01F6 Basic 26 3.6 208 20 16 1-Phase (L-N) IEC C20 100-240V Inlet Basic PDU, (24) IEC C13 + (... None None 0U Vertical None None false
C1W16HR-1ACA5BA5 Switched 16 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Switched PRO1, Per Input Po... PRO1 None 2U Horizontal None PIPS false
C1W16HR-1DCA5BA5 Switched 16 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Switched PRO1, Per Input Po... PRO1 None 2U Horizontal None PIPS false
C1W08HC-0ABA2BAC Switched 8 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1, 1U, 8 x IEC ... PRO1 None 1U Horizontal Sense PIPS false
C1W08HC-2CBA2BAC Switched 8 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1, 1U, 8 x IEC ... PRO1 None 1U Horizontal Sense PIPS false
C1W08HC-EPBA2BAC Switched 8 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1, 1U, 8 x IEC ... PRO1 None 1U Horizontal Sense PIPS false
C1S24VS-5PFA11F2 Smart 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Smart PRO1, 0U, 18 x IEC C1... PRO1 None 0U Vertical None Current (A) false
STV-4540K Switched 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
C1S24VS-4PFA11F2 Smart 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart PRO1, 0U, 18 x IEC C1... PRO1 None 0U Vertical None Current (A) false
STV-3531A Smart 30 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-3531D Smart 30 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-4541A Switched 24 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4541D Switched 24 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4540A Switched 24 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4540D Switched 24 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
C-12H2C211 Metered 12 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Metered PDU, 1U, 12 IEC C13... None None 1U Horizontal None Current (A) false
C-12H1B211E7 Metered 12 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Metered PDU, 1U, 12 IEC C13... None None 1U Horizontal None Current (A) false
C-12HEK211 Metered 12 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Metered PDU, 1U, 12 IEC C13... None None 1U Horizontal None Current (A) false
C1W24VT-5BPA15AC Switched 24 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-30P Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W08HC-1ACA2BA5 Switched 8 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Switched PRO1, PIPS (Per In... PRO1 None 1U Horizontal Sense PIPS false
C1W08HC-1DCA2BA5 Switched 8 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Switched PRO1, PIPS (Per In... PRO1 None 1U Horizontal Sense PIPS false
C1W16VS-1AFA17A5 Switched 16 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Switched PRO1, 0U, 16 x NEM... PRO1 None 0U Vertical Sense PIPS false
C1W16VS-1DFA17A5 Switched 16 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Switched PRO1, 0U, 16 x NEM... PRO1 None 0U Vertical Sense PIPS false
C1W24VS-DEFA11AC Switched 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO1, 0U, (24) IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DBFA11AC Switched 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO1, 0U, 24 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-YCFA11A0 Switched 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO1, 0U, 24 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DCFA11AC Switched 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO1, 0U, 24 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-YBFA11A0 Switched 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO1, 0U, 24 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W08HC-0A002BAC Switched 8 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1, 1U, 8 x IEC ... PRO1 None 1U Horizontal None PIPS false
STV-3531J Smart 30 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-3531B Smart 30 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-3531K Smart 30 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-3531G Smart 30 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-3531C Smart 30 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PRO1, PIPS (Per Input... PRO1 None 0U Vertical None PIPS false
STV-4541K Switched 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4541J Switched 24 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4541C Switched 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4541B Switched 24 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
STV-4540C Switched 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1 with PIPS (Pe... PRO1 None 0U Vertical Sense PIPS false
C1W24VS-YCFA13C9 Switched 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-YCFA11C9 Switched 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-YBFA11C9 Switched 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DEFA13A1 Switched 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DEFA11A1 Switched 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DCFA13A1 Switched 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DCFA11A1 Switched 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W24VS-DBFA11A1 Switched 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO1, 0U, 18 x IEC... PRO1 None 0U Vertical Sense Current (A) false
C1W16VS-0AFA17AC Switched 16 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W16VS-2CFA17AC Switched 16 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
C1W16VS-EPFA17AC Switched 16 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
STV-2001G Metered 30 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Metered PDU, 0U, (24) IEC C... None None 0U Vertical None Current (A) false
C1WG24VT-DQBA54F2 Switched POPS 24 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched POPS PDU, 0U, 24 O... PRO1 POPS 0U Vertical Sense Current (A) false
C1WG24VT-YQBA54F2 Switched POPS 24 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS PDU, 0U, 24 O... PRO1 POPS 0U Vertical Sense Current (A) false
C1WG24VT-DFBA54F2 Switched POPS 24 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS PDU, 0U, 24 O... PRO1 POPS 0U Vertical Sense Current (A) false
C1W16VS-OAFA17AC Switched 16 3.6 230 16 16 1-Phase (L-N) IEC C20 100-240V Inlet Switched PRO1, PIPS (Per In... PRO1 None 0U Vertical Sense PIPS false
STV-2001C Metered 30 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Metered PDU, 0U, (24) IEC C... None None 0U Vertical None Current (A) false
STV-2001K Metered 30 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Metered PDU, 0U, (24) IEC C... None None 0U Vertical None Current (A) false
PTTS-H008-0-02M FSTS 8 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Sentry Fail Safe Transfer S... None None 1U Horizontal None None false
PTTS-H008-O-02M FSTS 8 1.9 120 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Sentry Fail Safe Transfer S... None None 1U Horizontal None None false
CB-12H1-C20 Basic 12 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Basic PDU, 12 NEMA 5-20R ou... None None 1U Horizontal None None false
CB-12H2-L630 Basic 12 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Basic PDU, 12 IEC C13 outle... None None 1U Horizontal None None false
CB-26VOAE01F6 Basic 26 1.9 120 16 16 1-Phase (L-N) IEC C20 100-240V Inlet Basic PDU, (24) IEC C13 + (... None None 0U Vertical None None false
CB-12H2-C20 Basic 12 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Basic PDU, 12 IEC C13 outle... None None 1U Horizontal None None false
C1W24VS-1AFA25A5 Switched 24 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet PRO1 Switched PDU with PIPS... PRO1 None 0U Vertical Sense PIPS false
CB-12H1-L530 Basic 12 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Basic PDU, 12 NEMA 5-20R ou... None None 1U Horizontal None None false
STV-3534A Smart 30 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P PRO1 Smart Primary PIPS, 0U... PRO1 None 0U Vertical None PIPS false
STV-3534C Smart 30 11.5 415 20 16 3-Phase Wye (L-N) 240/415V Wye 20A IEC 60309 3P+N+G 6Hr PRO1 Smart Primary PIPS, 0U... PRO1 None 0U Vertical None PIPS false
STV-3534D Smart 30 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr PRO1 Smart Primary PIPS, 0U... PRO1 None 0U Vertical None PIPS false
STV-3534J Smart 30 11.0 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr PRO1 Smart Primary PIPS, 0U... PRO1 None 0U Vertical None PIPS false
STV-3534K Smart 30 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr PRO1 Smart Primary PIPS, 0U... PRO1 None 0U Vertical None PIPS false
STV-3534Z Smart 30 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P PRO1 Smart Primary PIPS, 0U... PRO1 None 0U Vertical None PIPS false