What's the best PDU solution for your data center?

Let us break it down for you.




At Server Technology, we understand that power needs vary from customer to customer. Some data centers require all-in-one power solutions complete with all the available bells and whistles, while others have more basic needs. But one thing that doesn't vary is the desire for a best-in-class high quality power product.

Sales Engineer Amanda Senger says Server Technology's large selection of PDUs is a major differentiator among its competitors.

“We're really good at one thing: PDUs. We have over 2,000 different part numbers, where our competitors only have 100-200, so we have a lot more flexibility we can offer our customers."

Amanda Senger
Sales Engineer, Server Technology

With so many options to choose from, it's easy to become overwhelmed when deciding which power solution is right for your data center. With this in mind, we've created a handy rack PDU selection wizard and flow chart that addresses all levels of power needs – from basic, non-metered PDUs to Switched POPS with outlet-level power monitoring.

"Ultimately," Senger says, "there's a solution for everyone with Server Technology's PDU lineup. Whether your needs are basic or complex, we offer a solution for you. Even if you don't need power monitoring, you're probably still going to want a high outlet count in a high-quality PDU."

Outlet Level Monitoring

Do you need outlet level monitoring?


POPS - Per Outlet Power Sensing

POPS® (Per Outlet Power Sensing)
Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.


The All-In-One POPS rack PDU is the right choice for your data center if you want outlet-level power monitoring. POPS is the perfect feature for those who need to understand how much power they're using for each device in the data center. POPS PDUs are available with or without outlet-level ON/OFF control.

×

Individual Outlet Control

Do you need individual outlet control?


Individual Outlet Control

Outlet Control
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.


The Switched rack PDU is the right choice for your data center if you want outlet-level ON/OFF control. Switched outlets are the perfect feature for those who need to reboot locked-up devices whether down the hall or thousands of miles away. Switched PDUs are available with or without outlet-level power monitoring.

×

You Need SWITCHED POPS


Individual Outlet Control

Outlet Control
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.


Per Outlet Power Sensing - POPS

POPS® (Per Outlet Power Sensing)
Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.

×

You Need SMART POPS


Remote Network Monitoring

IP Access, Security & Communications
Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.


POPS - Per Outlet Power Sensing

POPS® (Per Outlet Power Sensing)
Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.

×

Individual Outlet Control

Do you need individual outlet control?


Individual Rack PDU Outlet Control

Outlet Control
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.


The Switched rack PDU is the right choice for your data center if you want outlet-level ON/OFF control. Switched outlets are the perfect feature for those who need to reboot locked-up devices whether down the hall or thousands of miles away. Switched PDUs are available with or without outlet-level power monitoring.

×

You Need SWITCHED PDU


Rack PDU Network Monitoring

IP Access, Security & Communications
Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.


Rack PDU Outlet Control

Outlet Control
On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.

×

Network Monitoring

Do you need network monitoring?


Rack PDU Network Monitoring

IP Access, Security & Communications
Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.


The Smart rack PDU is the right choice for your data center if you want remote rack-level power monitoring, without access to individual outlets. Network monitoring is the perfect feature for those who need to track power and environmental conditions of numerous data center racks. Smart PDUs are available with or without outlet-level power monitoring.

×

You Need SMART PDU


Rack PDU Network Monitoring

IP Access, Security & Communications
Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.


Linkable Expansion Rack-PDU

Linkable Expansion
Connect an Expansion PDU to a Master PDU for power monitoring of separate power circuits from a single IP address.

×

Current Display

Do you need current display?


Rack-PDU Current Monitor

Input Current Monitoring
Easy-to-read LEDs display current per phase to help prevent overloads & simplify 3-phase load balancing in high density cabinets.


The Metered rack PDU is the right choice for your data center if you want on-site display of current, but aren't concerned with changes over time. Local metering is the perfect feature for those who need the device installer to be aware of load thresholds and load balancing. Local meters are also standard on all levels of intelligent rack PDUs.

×

You Need METERED PDU


Rack PDU Branch Circuit Protection

Branch Circuit Protection
This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.


Rack-PDU Input Current Monitor

Input Current Monitoring
Easy-to-read LEDs display current per phase to help prevent overloads & simplify 3-phase load balancing in high density cabinets.

×

You Need BASIC PDU


Rack-PDU Branch Cuircuit Protection

Branch Circuit Protection
This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.


Flexible Mounting for Rack-PDU

Flexible Mounting
This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).

×

Rack PDU Features

  • Branch Circuit Protection - Rack PDU Feature
  • High Density Outlet Technology - Rack PDU Feature
  • Input Current Monitor - Rack PDU Feature
  • Alternating Phase - Rack PDU Feature
  • Environmental Monitoring - Rack PDU Feature
  • Branch Circuit Monitoring - Rack PDU Feature
  • Linkable Expansion - Rack PDU Feature
  • High-Temperature Rating - Rack PDU Feature
  • Star Multi-Linking - Rack PDU Feature
  • Hot-Swap Network Card - Rack PDU Feature
  • Network Monitoring - Rack PDU Feature
  • Power Pivot rotatable power cord - Rack PDU Feature
  • Outlet Control - Rack PDU Feature
  • ST Eye Bluetooth Ready - Rack PDU Feature
  • POPS - Per Outlet Power Sensing - Rack PDU Feature
  • PIPS - Per Inlet Power Sensing - Rack PDU Feature
  • Flexible Mounting - Rack PDU Feature
  • High Cable Retention - Rack PDU Feature
  • Startup Stick - Rack PDU Feature
  • Color Coded Rack PDUs - Rack PDU Feature
Expand Feature Legend
Branch Circuit Protection - Rack PDU Feature
Branch Circuit Protection

This rack PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.

High Density Outlet Technology - Rack PDU Feature
High-Density Outlet Technology

The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention and UL94V-0 flame rating.

Input Current Monitor - Rack PDU Feature
Input Current Monitoring

Easy-to-read LEDs display current per phase to help prevent overloads & simplify 3-phase load balancing in high density cabinets.

Alternating Phase - Rack PDU Feature
Alternating-Phase Outlets

3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow.

Environmental Monitoring - Rack PDU Feature
Temperature/Humidity Monitoring

Master and Link (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.

Branch Circuit Monitoring - Rack PDU Feature
Branch Current Monitoring

PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.

Linkable Expansion - Rack PDU Feature
Linkable Expansion

Connect an Expansion PDU to a Master PDU for power monitoring of separate power circuits from a single IP address.

High-Temperature Rating - Rack PDU Feature
High Temperature Rating

This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments.

Star Multi-Linking - Rack PDU Feature
Star Multi-Linking

PRO2 provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.

Hot-Swap Network Card - Rack PDU Feature
Hot-Swap Network Card

Network access is ensured when power is lost to the Master unit with backup power provided by the primary link unit.

Network Monitoring - Rack PDU Feature
IP Access, Security & Communications

Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.

Power Pivot rotatable power cord - Rack PDU Feature
Power Pivot™

The 90 degree rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.

Outlet Control - Rack PDU Feature
Outlet Control

On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.

ST Eye Bluetooth Ready - Rack PDU Feature
ST Eye Bluetooth Ready

The best rack PDU LCD is the one in your hand. Attach the ST Eye™ Bluetooth module to this PDU for access to power data and system settings.

POPS - Per Outlet Power Sensing - Rack PDU Feature
POPS® (Per Outlet Power Sensing)

Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.

Flexible Mounting - Rack PDU Feature
Flexible Mounting

This rack PDU includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details).

PIPS - Per Inlet Power Sensing - Rack PDU Feature
PIPS® (Per Inlet Power Sensing)

Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.

High Cable Retention - Rack PDU Feature
Cable Retention

Reduces accidental disconnects by ensuring that power cords are solidly connected to their respective devices.

Startup Stick - Rack PDU Feature
Startup Stick™

The quick and easy solution to CDU configuration when DHCP is not available.

Color Coded Rack PDUs - Rack PDU Feature
Color Coded Rack PDUs

Select from six colors to designate PDU circuits in the data center — black, white, red, green, blue, and yellow.

×

“Whether your needs are basic or complex, we offer a solution for you," Senger says. “Even if you don't need power monitoring, you're probably still going to want a high outlet count in a high-quality PDU."

Rack PDU Product Family Overview

×