Model # Type Total Outlets Input Power Capacity Input Nominal Voltage Input Current Input Current Rated Phase Plug Type Description Branch Monitoring Outlet Monitoring Dimensions Mounting PDU Platform Input Monitoring Alt Phase C4S48RA-2QBE2FD7 Smart 48 10.0 208 60 48 1-Phase (L-L) IEC 208V/60A 2P+G 6Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 1PH 60A (48A Rated) IEC 60309 2P+G 6Hr Blue 2P+G Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-ENBE2FD7 Smart 48 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 60A (48A Rated) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-EPBE2FD7 Smart 48 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 32A IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-EQBE2FD7 Smart 48 11.0 230 63 48 1-Phase (L-N) IEC 230V/63A 2P+PE 6Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 63A (De-rated to 48A) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-DBBE2FD7 Smart 48 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 20A (16A Rated) NEMA L15-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-DCBE2FD7 Smart 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 30A (24A Rated) NEMA L15-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-YBBE2FD8 Smart 48 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 20A (16A Rated) NEMA L21-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-YCBE2FD8 Smart 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-5BBD2FD3 Smart 48 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 220/380V-240/415V 3-phase 20A (16A Rated) NEMA L22-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-5CBD2FD3 Smart 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 220/380V-240/415V 3-phase 30A (24A Rated) NEMA L22-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-GNBD2FD3 Smart 48 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 20A (16A Rated) IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-GPBD2FD3 Smart 48 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 30A (24A Rated for North America/Canada)/32A IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-DFBD2FD3 Smart 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 50A (40A Rated) CS8365 Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-DQBD2FD3 Smart 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-YQBD2FD3 Smart 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 60A (48A Rated) IEC 60309 3P+N+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-0ABE2FD7 Switched 48 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120-240V 20A (16A) IEC C20 Inlet, Bottom/Angled Cord Entry (Input Cord Not Included and Must Be Specified Separately), Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-2BBE2FD7 Switched 48 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 20A (16A Rated) NEMA L6-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-2CBE2FD7 Switched 48 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 30A (24A Rated) NEMA L6-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-2QBE2FD7 Switched 48 10.0 208 60 48 1-Phase (L-L) IEC 208V/60A 2P+G 6Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 1PH 60A (48A Rated) IEC 60309 2P+G 6Hr Blue 2P+G Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-ENBE2FD7 Switched 48 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 60A (48A Rated) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-EPBE2FD7 Switched 48 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 32A IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-EQBE2FD7 Switched 48 11.0 230 63 48 1-Phase (L-N) IEC 230V/63A 2P+PE 6Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 63A (De-rated to 48A) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-DBBE2FD7 Switched 48 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 20A (16A Rated) NEMA L15-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-DCBE2FD7 Switched 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 30A (24A Rated) NEMA L15-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-YBBE2FD8 Switched 48 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 20A (16A Rated) NEMA L21-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-YCBE2FD8 Switched 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-5BBD2FD3 Switched 48 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 220/380V-240/415V 3-phase 20A (16A Rated) NEMA L22-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-5CBD2FD3 Switched 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 220/380V-240/415V 3-phase 30A (24A Rated) NEMA L22-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-GNBD2FD3 Switched 48 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 20A (16A Rated) IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-GPBD2FD3 Switched 48 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 30A (24A Rated for North America/Canada)/32A IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-DFBD2FD3 Switched 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 50A (40A Rated) CS8365 Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-DQBD2FD3 Switched 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W48RA-YQBD2FD3 Switched 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 60A (48A Rated) IEC 60309 3P+N+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-0ABE2FD7 Switched POPS 48 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120-240V 20A (16A) IEC C20 Inlet, Bottom/Angled Cord Entry (Input Cord Not Included and Must Be Specified Separately), Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-2BBE2FD7 Switched POPS 48 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 20A (16A Rated) NEMA L6-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-2CBE2FD7 Switched POPS 48 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 30A (24A Rated) NEMA L6-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-2QBE2FD7 Switched POPS 48 10.0 208 60 48 1-Phase (L-L) IEC 208V/60A 2P+G 6Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 1PH 60A (48A Rated) IEC 60309 2P+G 6Hr Blue 2P+G Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-ENBE2FD7 Switched POPS 48 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 60A (48A Rated) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-EPBE2FD7 Switched POPS 48 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 32A IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-EQBE2FD7 Switched POPS 48 11.0 230 63 48 1-Phase (L-N) IEC 230V/63A 2P+PE 6Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 230V 1PH 63A (De-rated to 48A) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-DBBE2FD7 Switched POPS 48 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 20A (16A Rated) NEMA L15-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-DCBE2FD7 Switched POPS 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 30A (24A Rated) NEMA L15-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-YBBE2FD8 Switched POPS 48 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 20A (16A Rated) NEMA L21-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-YCBE2FD8 Switched POPS 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-5BBD2FD3 Switched POPS 48 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 220/380V-240/415V 3-phase 20A (16A Rated) NEMA L22-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-5CBD2FD3 Switched POPS 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 220/380V-240/415V 3-phase 30A (24A Rated) NEMA L22-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-GNBD2FD3 Switched POPS 48 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 20A (16A Rated) IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-GPBD2FD3 Switched POPS 48 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 30A (24A Rated for North America/Canada)/32A IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-DFBD2FD3 Switched POPS 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 50A (40A Rated) CS8365 Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-DQBD2FD3 Switched POPS 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G48RA-YQBD2FD3 Switched POPS 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120/208V 3-phase 60A (48A Rated) IEC 60309 3P+N+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) POPS 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-0ABE2FE2 Smart 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120-240V 20A (16A) IEC C20 Inlet, Bottom/Angled Cord Entry (Input Cord Not Included and Must Be Specified Separately), Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-2BBE2FE2 Smart 36 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 20A (16A Rated) NEMA L6-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-2CBE2FE2 Smart 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 30A (24A Rated) NEMA L6-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-2QBE2FE2 Smart 36 10.0 208 60 48 1-Phase (L-L) IEC 208V/60A 2P+G 6Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 1PH 60A (48A Rated) IEC 60309 2P+G 6Hr Blue 2P+G Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-ENBE2FE2 Smart 36 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 60A (48A Rated) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-EPBE2FE2 Smart 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 32A IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-EQBE2FE2 Smart 36 11.0 230 63 48 1-Phase (L-N) IEC 230V/63A 2P+PE 6Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 63A (De-rated to 48A) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-DBBE2FE2 Smart 36 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 20A (16A Rated) NEMA L15-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-DCBE2FE2 Smart 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 30A (24A Rated) NEMA L15-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-YBBE2FE3 Smart 36 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 20A (16A Rated) NEMA L21-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-YCBE2FE3 Smart 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-5BBD2FE1 Smart 36 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V 3-phase 20A (16A Rated) NEMA L22-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-5CBD2FE1 Smart 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V 3-phase 30A (24A Rated) NEMA L22-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-GNBD2FE1 Smart 36 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 20A (16A Rated) IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-GPBD2FE1 Smart 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 30A (24A Rated for North America/Canada)/32A IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-DFBD2FE1 Smart 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 50A (40A Rated) CS8365 Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-DQBD2FE1 Smart 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S36RA-YQBD2FE1 Smart 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 60A (48A Rated) IEC 60309 3P+N+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-0ABE2FE2 Switched 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120-240V 20A (16A) IEC C20 Inlet, Bottom/Angled Cord Entry (Input Cord Not Included and Must Be Specified Separately), Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-2BBE2FE2 Switched 36 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 20A (16A Rated) NEMA L6-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-2CBE2FE2 Switched 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 30A (24A Rated) NEMA L6-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-2QBE2FE2 Switched 36 10.0 208 60 48 1-Phase (L-L) IEC 208V/60A 2P+G 6Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 1PH 60A (48A Rated) IEC 60309 2P+G 6Hr Blue 2P+G Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-ENBE2FE2 Switched 36 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 60A (48A Rated) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-EPBE2FE2 Switched 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 32A IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-EQBE2FE2 Switched 36 11.0 230 63 48 1-Phase (L-N) IEC 230V/63A 2P+PE 6Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 63A (De-rated to 48A) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-DBBE2FE2 Switched 36 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 20A (16A Rated) NEMA L15-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-DCBE2FE2 Switched 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 30A (24A Rated) NEMA L15-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-YBBE2FE3 Switched 36 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 20A (16A Rated) NEMA L21-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-YCBE2FE3 Switched 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-5BBD2FE1 Switched 36 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V 3-phase 20A (16A Rated) NEMA L22-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-5CBD2FE1 Switched 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V 3-phase 30A (24A Rated) NEMA L22-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-GNBD2FE1 Switched 36 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 20A (16A Rated) IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-GPBD2FE1 Switched 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 30A (24A Rated for North America/Canada)/32A IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-DFBD2FE1 Switched 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 50A (40A Rated) CS8365 Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-DQBD2FE1 Switched 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4W36RA-YQBD2FE1 Switched 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 60A (48A Rated) IEC 60309 3P+N+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) None 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-0ABE2FE2 Switched POPS 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120-240V 20A (16A) IEC C20 Inlet, Bottom/Angled Cord Entry (Input Cord Not Included and Must Be Specified Separately), Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-2BBE2FE2 Switched POPS 36 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 20A (16A Rated) NEMA L6-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-2CBE2FE2 Switched POPS 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 30A (24A Rated) NEMA L6-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-2QBE2FE2 Switched POPS 36 10.0 208 60 48 1-Phase (L-L) IEC 208V/60A 2P+G 6Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208V 1PH 60A (48A Rated) IEC 60309 2P+G 6Hr Blue 2P+G Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-ENBE2FE2 Switched POPS 36 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 60A (48A Rated) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-EPBE2FE2 Switched POPS 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 32A IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-EQBE2FE2 Switched POPS 36 11.0 230 63 48 1-Phase (L-N) IEC 230V/63A 2P+PE 6Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 230V 1PH 63A (De-rated to 48A) IEC 60309 1P+N+G 6Hr Blue Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-DBBE2FE2 Switched POPS 36 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 20A (16A Rated) NEMA L15-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-DCBE2FE2 Switched POPS 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 30A (24A Rated) NEMA L15-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-YBBE2FE3 Switched POPS 36 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 20A (16A Rated) NEMA L21-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-YCBE2FE3 Switched POPS 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 30A (24A Rated) NEMA L21-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-5BBD2FE1 Switched POPS 36 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V 3-phase 20A (16A Rated) NEMA L22-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-5CBD2FE1 Switched POPS 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 220/380V-240/415V 3-phase 30A (24A Rated) NEMA L22-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true