Model # Type Total Outlets Input Power Capacity Input Nominal Voltage Input Current Input Current Rated Phase Plug Type Description Branch Monitoring Outlet Monitoring Dimensions Mounting PDU Platform Input Monitoring Alt Phase C1W24VS-1DFA25A5 Switched 24 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P PRO1 Switched PDU with PIPS (Per Input Power Sensing), 0U, 24 x NEMA 5-20R Outlets, (1) Input LED Amp Meter in the middle of the unit, 120V 30A Input w/ NEMA L5-30P Plug, Bottom/Front Cord Entry, (2) Temp/Humidity Sensor Capable, Fuses Sense None 1.75 x 65.5 x 3.0 in. (45.0 x 1664.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false C1W24VT-5PPA17AC Switched 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 240/415V 3-phase, 30A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Bottom Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1W24VT-5CPA17AC Switched 24 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 240/415V 3-phase, 30A NEMA L22-30P Plug, Bottom/Bottom Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false 48DCWC-16-2X100-A0 -48 VDC 16 9.6 -48 200 200 DC Terminals PRO1 -48VDC Remote Power Manager, (16) 10A switched outputs w/ Load-Sense, 10A GMT fuses included (other values available), dual 100A input blocks, supports two temperature/humidity probes, STI black paint None Current (A) 17.0 x 3.5 x 13.11 in. (432.0 x 89.0 x 333.0 mm.) 2U Horizontal PRO1 None false 48DCWC-12-2X100-A1NB -48 VDC 12 9.6 -48 200 200 DC Terminals PRO1 -48 VDC Remote Power Manager, (8) switched Low Amp outputs @ 10A Max, (4) Switched High Amp outputs @ 70A Max, w/ Load-Sense, dual 100A input blocks, two (2) temperature/humidity sensor support, STI Black Paint, NEBS certified, Includes (8) 10A GMT fuses, (4) TPC fuses supplied at no charge but must be specified at time of order. None Current (A) 17.0 x 3.5 x 17.58 in. (432.0 x 89.0 x 447.0 mm.) 2U Horizontal PRO1 None false 48DCWC-08-2X100-B0NB -48 VDC 8 9.6 -48 200 200 DC Terminals PRO1 -48 VDC Remote Power Manager, eight (8) switched outputs @ 20A (fused up-to 25A max) w/ Load-Sense, dual 100A input blocks, (8) TPC fuses supplied at no charge but must be specified at time of order, two (2) temperature/humidity sensor support, STI Black Paint, NEBS certified None Current (A) 17.0 x 3.5 x in. (432.0 x 89.0 x 0.0 mm.) 2U Horizontal PRO1 None false 48DCWC-04-4X070-D0NB -48 VDC 4 13.4 -48 280 280 DC Terminals PRO1 -48 VDC Remote Power Manager, 2.5U, (4) Switched Outputs @ 70A (Fused up-to 75A max) w/ Load-Sense, (4) 70A Inputs, (4) TPC fuses supplied at no charge but must be specified at time of order, (2) Temperature/Humidity Sensor Capable, NEBS certified None Current (A) 17.0 x 4.4 x 17.5 in. (432.0 x 112.0 x 445.0 mm.) 2.5U Horizontal PRO1 None false 48DCWC-10-2X300-E0NB -48 VDC 10 28.8 -48 600 600 DC Terminals PRO1 -48 VDC Remote Power Manager, 3U, (10) Switched Outputs Rated Up To 125A (10 Fuses/Breakers Not Included) w/ Outlet Current Monitoring, Two (2) 300A -48V Inputs, (2) Temperature/Humidity Sensor Capable (Fuse/Circuit Breakers and Holders Ordered Separately), NEBS certified None Current (A) 17.0 x 5.25 x in. (432.0 x 134.0 x 0.0 mm.) 3U Horizontal PRO1 None false 48DCWC-04-4X125-E0NB -48 VDC 4 24.0 -48 500 500 DC Terminals PRO1 -48 VDC Remote Power Manager, 2.5U, (4) Switched Outputs @ 125A (Fused up-to 125A max) w/ Load-Sense, (4) 125A Inputs, (4) TPC fuses supplied at no charge but must be specified at time of order, (2) Temperature/Humidity Sensor Capable, NEBS certified None Current (A) 17.0 x 4.4 x in. (432.0 x 112.0 x 0.0 mm.) 2.5U Horizontal PRO1 None false 48DCWC-16-2X600-E0 -48 VDC 16 57.6 -48 1200 1200 DC Terminals PRO1 Switched -48 VDC Remote Power Manager, 4U, (16) Switched Outputs Rated Up To 125A w/ Outlet Current Monitoring, Two (2) 600 A -48 VDC Inputs, (2) Temperature/Humidity Sensor Capable, Bullet Circuit Breakers or TPC Fuse Along With Holders Must Be Ordered Separately None Current (A) 17.0 x 7.0 x in. (432.0 x 178.0 x 0.0 mm.) 4U Horizontal PRO1 None false 48DCWC-04-2X100-D0NB -48 VDC 4 9.6 -48 200 200 DC Terminals PRO1 -48 VDC Remote Power Manager, four (4) switched outputs @ 70A (fused up-to 75A max) w/ Load-Sense, dual 100A input blocks, (4) TPC fuses supplied at no charge but must be specified at time of order, two (2) temperature/humidity sensor support, STI Black Paint, NEBS certified None Current (A) 17.0 x 3.5 x 17.5 in. (432.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO1 None false