Model # Type Total Outlets Input Power Capacity Input Nominal Voltage Input Current Input Current Rated Phase Plug Type Description Branch Monitoring Outlet Monitoring Dimensions Mounting PDU Platform Input Monitoring Alt Phase C1S42CA-DQME2700 Smart 42 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr PRO1 Smart Primary PIPS (42) HDOT (42xC13) 208V 3PH Delta 60A IEC 60309 Blue 9hr 3P+G, 3m (10ft) Bottom/base Entry Power Cord, Mid Display, Breakers, Phase Monitoring, (2) Temperature/humidity Sensor Capable Sense None 1.75 x 70.0 x 3.5 in. (45.0 x 1778.0 x 89.0 mm.) 0U Vertical PRO1 PIPS true C1S42CA-DFME2700 Smart 42 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A PRO1 Smart Primary PIPS (42) HDOT (42xC13) 208V 3PH Delta 50A CS8365, 3m (10ft) Bottom/base Entry Power Cord, Mid Display, Breakers, Phase Monitoring, (2) Temperature/humidity Sensor Capable Sense None 1.75 x 70.0 x 3.5 in. (45.0 x 1778.0 x 89.0 mm.) 0U Vertical PRO1 PIPS true C1S36CA-DQME2766 Smart 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr PRO1 Smart Primary PIPS (36) HDOT (24xC13 + 12xC19) 208V 3PH Delta 60A IEC 60309 Blue 9hr 3P+G, 3m (10ft) Bottom/base Entry Power Cord, Mid Display, Breakers, Phase Monitoring, (2) Temperature/humidity Sensor Capable Sense None 1.75 x 70.0 x 3.5 in. (45.0 x 1778.0 x 89.0 mm.) 0U Vertical PRO1 PIPS true C1S14CS-OABA150 Smart 14 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart Primary Pro1 PIPS V14 HDOT (14)C13 HDOT Outlets, 100-240V, 1PH, 2BR, 16A, C20 Inlet, Bottom Front Entry, Auto-Orient Top Display, Flush Breakers, Line Monitoring, WxD = 1.75in x 2.25in None None 1.75 x 37.25 x 2.25 in. (45.0 x 947.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-2001B Metered 30 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Metered PDU, 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 208-240V 20A, NEMA L6-20P Plug, 9ft (2.74m) Cord w/ Power Pivot Cord Entry, Middle Display, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical None Current (A) false C1S24VS-DBFA11AC Smart 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Smart PRO1, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Delta 20A Input w/ NEMA L15-20P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C-12H0A111 Metered 12 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Metered PDU, Horizontal Mount, 1U, 12 x IEC C13 Outlets, LED amp meter, 100-240V, 16A/20A w/ C20 Inlet (Input power cord ordered separately) None None 17.2 x 1.75 x in. (437.0 x 45.0 x 0.0 mm.) 1U Horizontal None Current (A) false STV-2001J Metered 30 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Metered PDU, 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 230V 16A, IEC 60309 6hr 3 Pin Blue Plug, 2.74 m (9 ft) Cord, w/ Power Pivot Cord Entry, Middle Display, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical None Current (A) false C1W16HR-0AAA5BAC Switched 16 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1 with PIPS (Per Inlet Power Sensing), 2U, 16 x IEC C13 Outlets, Input Amp Meter, 100-240V, 20A Input w/ IEC 60320 C20 Inlet (Front Cord Entry), 20A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Sense None 17.2 x 3.5 x 7.1 in. (437.0 x 89.0 x 181.0 mm.) 2U Horizontal PRO1 PIPS false C1W16HR-2CAA5BAC Switched 16 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Sense None 17.2 x 3.5 x 7.1 in. (437.0 x 89.0 x 181.0 mm.) 2U Horizontal PRO1 PIPS false C1W24VT-4PPA15AC Switched 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 230/400V 3-phase, 32A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1W24VT-4NPA15AC Switched 24 11.1 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 230/400V 3-phase, 16A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1W16HR-EPAA5BAC Switched 16 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord (Front Cord Entry), (2) Temperature/Humidity Sensor Capable, 20 A Circuit Breakers Sense None 17.2 x 3.5 x 7.1 in. (437.0 x 89.0 x 181.0 mm.) 2U Horizontal PRO1 PIPS false C1W24VT-5PPA15AC Switched 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 240/415V 3-phase, 30A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1W24VT-5CPA15AC Switched 24 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 240/415V 3-phase, 30A NEMA L22-30P Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1W24VT-5NPA15AC Switched 24 11.5 415 20 16 3-Phase Wye (L-N) 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 240/415V 3-phase, 20A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1S24VS-YBFA11A0 Smart 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PRO1, 0U, 24 x IEC C13 Outlets, (1) NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 20A Input w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1S24VS-YBFA13A0 Smart 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PRO1, 0U, 24 x IEC C13 Outlets, (1) NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 20A Input w/ NEMA L21-20P Connector, 10ft (3m) Bottom/End Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VT-45PA15AC Switched 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V 56 Series 56P532 Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 230/400V 3-phase, 32A with 56 Series 56P532 Orange Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1S24VS-YCFA11A0 Smart 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO1, 0U, 24 x IEC C13 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1S24VS-DEFA11AC Smart 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO1, 0U, (24) IEC C13 Outlets, (3) LED amp meters, 208V 3-phase 50A Delta input (Derated to 35A, true 12.6kW) w/ CS8365 connector and cord 10ft (3m) bottom/front cord entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1S24VS-DCFA11AC Smart 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO1, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3-phase Delta 30A Input w/ NEMA L15-30P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1S24VS-YCFA13A0 Smart 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO1, 0U, 24 x IEC C13 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord (Bottom/base Entry), (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1S24VS-DCFA13AC Smart 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO1, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3-phase Delta 30A Input w/ NEMA L15-30P Connector, 10ft (3m) Bottom/End Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1S15HN-YQJN5BC3-013 Smart 15 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart PRO1 with PIPS (Per Input Power Sensing), 2U, 12xC19 and 3xC13 Alt-Phase Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Wye 60A, 10 ft (3 m) Cord, IEC 60309 9hr 5Pin Blue plug, Circuit Breakers, 2 x Temp/Humid Capable None None 17.2 x 3.5 x 10.1 in. (437.0 x 89.0 x 257.0 mm.) 2U Horizontal PRO1 PIPS false C1S15HN-DQJN5BC3-013 Smart 15 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Smart PRO1 with PIPS (Per Input Power Sensing), 2U, 12xC19 and 3xC13 Alt-Phase Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Delta 60A, 10 ft (3 m) Cord, IEC 60309 9hr 4Pin Blue plug, Circuit Breakers, 2 x Temp/Humid Capable None None 17.2 x 3.5 x 10.1 in. (437.0 x 89.0 x 257.0 mm.) 2U Horizontal PRO1 PIPS false C1S15HN-DFJN5BC3-013 Smart 15 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO1 with PIPS (Per Input Power Sensing), 2U, 12xC19 and 3xC13 Alt-Phase Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Delta 50A, 10 ft (3 m) Cord, CS8365 Plug, Circuit Breakers, 2 x Temp/Humid Capable None None 17.2 x 3.5 x 10.1 in. (437.0 x 89.0 x 257.0 mm.) 2U Horizontal PRO1 PIPS false CB-26VEKE01F6 Basic 26 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Basic PDU, (24) IEC C13 + (2) IEC C19 Outlets, 230V, 32A, IEC 60309 2P+G Plug, 3 m Cord, Bottom/Front Cord Entry, Doghouse Circuit Breakers None None 1.75 x 35.5 x 3.39 in. (45.0 x 902.0 x 87.0 mm.) 0U Vertical None None false CB-26V2CE01F6 Basic 26 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Basic PDU, (24) IEC C13 + (2) IEC C19 Outlets, 200V-240V, 30A, NEMA L6-30P Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Doghouse Circuit Breakers None None 1.75 x 35.5 x 3.39 in. (45.0 x 902.0 x 87.0 mm.) 0U Vertical None None false CB-26V0AE01F6 Basic 26 3.6 208 20 16 1-Phase (L-N) IEC C20 100-240V Inlet Basic PDU, (24) IEC C13 + (2) IEC C19 Outlets, 120V, 200-240V, 230V, 16A, IEC C20 Inlet, Bottom/Front Cord Entry, Doghouse Circuit Breakers (Input Cord Must Be Ordered Separately) None None 1.75 x 35.5 x 3.39 in. (45.0 x 902.0 x 87.0 mm.) 0U Vertical None None false C1W16HR-1ACA5BA5 Switched 16 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Switched PRO1, Per Input Power Sensing, 2U, (16) NEMA 5-20R Outlets, Input Amp Meter, 120V 20A w/ IEC C20 Inlet, 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input Cord Sold Separately) None None 17.2 x 3.0 x 7.0 in. (437.0 x 77.0 x 178.0 mm.) 2U Horizontal PRO1 PIPS false C1W16HR-1DCA5BA5 Switched 16 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Switched PRO1, Per Input Power Sensing, 2U, (16) NEMA 5-20R Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable None None 17.2 x 3.0 x 7.0 in. (437.0 x 77.0 x 178.0 mm.) 2U Horizontal PRO1 PIPS false C1W08HC-0ABA2BAC Switched 8 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 120/208-240 20A and 230V 16A Rating w/ IEC C20 Inlet, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection (Input power cord ordered separately) Sense None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal PRO1 PIPS false C1W08HC-2CBA2BAC Switched 8 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3m (10ft) Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Sense None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal PRO1 PIPS false C1W08HC-EPBA2BAC Switched 8 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Sense None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal PRO1 PIPS false C1S24VS-5PFA11F2 Smart 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Smart PRO1, 0U, 18 x IEC C13 + 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-Phase Wye, 30A IEC 60309 (5-pin Pin/Sleeve, Red, 6 O'clock Ground) Connector, Bottom/Front Cord Entry, 3m (10ft) Cord, Fused Branch Circuit Protection, w/ (2) Temperature/Humidity Sensor Capable None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false STV-4540K Switched 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 32A Input w/ IEC 60309 6hr 3 Pin Blue Plug, 3m (10') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false C1S24VS-4PFA11F2 Smart 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart PRO1, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 400V input w/ IEC 60309 32A connector and cord 10', (2) Temperature/Humidity Sensor Capable, with retractable fuses None None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false STV-3531A Smart 30 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 208 20A w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers ** Input PTCORD-Lx power cord ordered separately ** None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-3531D Smart 30 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 230V 16A w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers ** Input PTCORD-Lx power cord ordered separately ** None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4541A Switched 24 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 208V 20A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers ** Input power cord ordered separately, USE PTCORD-Lx ** Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4541D Switched 24 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 16A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers ** Input power cord ordered separately, USE PTCORD-Lx ** Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4540A Switched 24 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Switched PRO1 with PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 208V 20A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers ** Input power cord ordered separately, USE PTCORD-Lx ** Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4540D Switched 24 3.6 230 16 16 1-Phase (L-N) IEC C20 230V Inlet Switched PRO1 with PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 16A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers ** Input power cord ordered separately, USE PTCORD-Lx ** Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false C-12H2C211 Metered 12 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Metered PDU, 1U, 12 IEC C13 Outlets, LED amp meter, 208V 30A input w L6-30P connector & cord, 10ft (3m) None None 17.2 x 1.75 x 5.0 in. (437.0 x 45.0 x 127.0 mm.) 1U Horizontal None Current (A) false C-12H1B211E7 Metered 12 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Metered PDU, 1U, 12 IEC C13 Outlets, LED amp meter, 120V 30A input w L5-30P connector & cord, 10ft (3m) None None 17.2 x 1.75 x 5.0 in. (437.0 x 45.0 x 127.0 mm.) 1U Horizontal None Current (A) false C-12HEK211 Metered 12 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Metered PDU, 1U, 12 IEC C13 Outlets, LED amp meter, 230V 32A input with IEC 60309 2P+G 6hr Red Connector, 3m (10ft) cord, Internally Fused None None 17.2 x 1.75 x 5.0 in. (437.0 x 45.0 x 127.0 mm.) 1U Horizontal None Current (A) false C1W24VT-5BPA15AC Switched 24 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-30P Switched PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 Outlets, (3) LED Amp Meters, 240/415V 3-phase, 20A NEMA L22-20P Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Sense None 1.75 x 69.0 x 3.5 in. (45.0 x 1753.0 x 89.0 mm.) 0U Vertical PRO1 PIPS false C1W08HC-1ACA2BA5 Switched 8 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Switched PRO1, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20R Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, Circuit Breakers (input power cord ordered separately) Sense None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal PRO1 PIPS false C1W08HC-1DCA2BA5 Switched 8 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Switched PRO1, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20R Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P Plug, 10 ft (3m) cord, 2 x Temp/Humid Capable, Circuit Breakers Sense None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal PRO1 PIPS false C1W16VS-1AFA17A5 Switched 16 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Switched PRO1, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses (Input power cord sold separately) Sense None 1.75 x 44.5 x in. (45.0 x 1131.0 x 0.0 mm.) 0U Vertical PRO1 PIPS false C1W16VS-1DFA17A5 Switched 16 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Switched PRO1, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 30A input w/ L5-30P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 44.5 x in. (45.0 x 1131.0 x 0.0 mm.) 0U Vertical PRO1 PIPS false C1W24VS-DEFA11AC Switched 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO1, 0U, (24) IEC C13 Outlets, (3) LED amp meters, 208V 3-phase 50A Delta input (Derated to 35A, true 12.6kW) w/ CS8365 connector and cord 10ft (3m) bottom/front cord entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DBFA11AC Switched 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO1, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Delta 20A Input w/ NEMA L15-20P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-YCFA11A0 Switched 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO1, 0U, 24 x IEC C13 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DCFA11AC Switched 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO1, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3-phase Delta 30A Input w/ NEMA L15-30P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-YBFA11A0 Switched 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO1, 0U, 24 x IEC C13 Outlets, (1) NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 20A Input w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W08HC-0A002BAC Switched 8 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 120/208-240 20A and 230V 16A Rating w/ IEC C20 Inlet, (2) Temperature/Humidity Sensor Capable, No Branch Circuit Protection (Input power cord ordered separately) None None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal PRO1 PIPS false STV-3531J Smart 30 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 230V 16A, IEC 60309 6hr 3 Pin Blue Plug, 2.75m (9 ft) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-3531B Smart 30 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 208-240V 20A, NEMA L6-20P Plug, 9 ft (2.74m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-3531K Smart 30 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 3m (10ft) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-3531G Smart 30 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 120/208-240 20A and 230V 16A Rating w/ IEC C20 Inlet, Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers ** Input PTCORD-Lx power cord ordered separately ** None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-3531C Smart 30 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PRO1, PIPS (Per Input Power Sensing), 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 208-240V 30A, NEMA L6-30P Plug, 10 ft (3m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4541K Switched 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 32A Input w/ IEC 60309 6hr 3 Pin Blue Plug, 3m (10') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4541J Switched 24 3.6 230 16 16 1-Phase (L-N) IEC 230V/16A 2P+PE 6Hr Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 16A Input w/ IEC 60309 6hr 3 Pin Blue Plug, 2.75m (9') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4541C Switched 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 208-240V 30A Input w/ NEMA L6-30P Plug, 3m (10') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4541B Switched 24 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 208-240V 20A Input w/ NEMA L6-20P Plug, 9 ft (2.74 m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-4540C Switched 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1 with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 208-240V 30A Input w/ NEMA L6-30P Plug, 3m (10') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense None 1.75 x 69.0 x 2.25 in. (45.0 x 1753.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false C1W24VS-YCFA13C9 Switched 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord (Bottom/base Entry), (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-YCFA11C9 Switched 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-YBFA11C9 Switched 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (1) NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 20A Input w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DEFA13A1 Switched 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (3) LED amp meters, 208V 3-phase 50A Delta input (Derated to 35A, true 12.6kW) w/ CS8365 connector and cord 10ft (3m) bottom/end cord entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DEFA11A1 Switched 24 12.5 208 50 35 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (3) LED amp meters, 208V 3-phase 50A Delta input (Derated to 35A, true 12.6kW) w/ CS8365 connector and cord 10ft (3m) bottom/front cord entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DCFA13A1 Switched 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3-phase Delta 30A Input w/ NEMA L15-30P Connector, 10ft (3m) Bottom/End Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DCFA11A1 Switched 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3-phase Delta 30A Input w/ NEMA L15-30P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W24VS-DBFA11A1 Switched 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Switched PRO1, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3 Phase Delta 20A Input w/ NEMA L15-20P Connector, 10ft (3m) Bottom/Front Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Sense None 1.75 x 69.0 x 3.0 in. (45.0 x 1753.0 x 77.0 mm.) 0U Vertical PRO1 Current (A) false C1W16VS-0AFA17AC Switched 16 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO1, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 100-240V C20 input, Bottom/Bottom Entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses (Input power cord ordered separately) Sense None 1.75 x 49.5 x 2.25 in. (45.0 x 1258.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false C1W16VS-2CFA17AC Switched 16 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO1, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 30A input w/ L6-30P, 10ft (3m), Bottom/Bottom Entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 49.5 x 2.25 in. (45.0 x 1258.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false C1W16VS-EPFA17AC Switched 16 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO1, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 32A input w/ IEC 60309 connector & cord, 10ft (3m), Bottom/Bottom Entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 49.5 x 2.25 in. (45.0 x 1258.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-2001G Metered 30 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Metered PDU, 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 120/208-240 20A and 230V 16A Rating, C20 Power Pivot Cord Entry, Middle Display, Circuit Breakers ** Input power cord ordered separately (PTCORD-Lx)** None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical None Current (A) false C1WG24VT-DQBA54F2 Switched POPS 24 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched POPS PDU, 0U, 24 Outlets (18xC13 + 6xC19), 3 LED Input Current Meters, 208V/3PH Delta/60A, IEC 60309 3P+G 9hr Blue Plug, 10 ft (3.05m), Top Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense POPS 1.75 x 70.0 x in. (45.0 x 1778.0 x 0.0 mm.) 0U Vertical PRO1 Current (A) false C1WG24VT-YQBA54F2 Switched POPS 24 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS PDU, 0U, 24 Outlets (18xC13 + 6xC19), 3 LED Input Current Meters, 208V/3PH Wye/60A, IEC 60309 3P+N+G 9hr Blue Plug, 10 ft (3.05m), Top Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense POPS 1.75 x 70.0 x in. (45.0 x 1778.0 x 0.0 mm.) 0U Vertical PRO1 Current (A) false C1WG24VT-DFBA54F2 Switched POPS 24 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS PDU, 0U, 24 Outlets (18xC13 + 6xC19), 3 LED Input Current Meters, 208V/3PH Delta/50A, CS8365 Plug, 10 ft (3.05m), Top Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Sense POPS 1.75 x 70.0 x in. (45.0 x 1778.0 x 0.0 mm.) 0U Vertical PRO1 Current (A) false C1W16VS-OAFA17AC Switched 16 3.6 230 16 16 1-Phase (L-N) IEC C20 100-240V Inlet Switched PRO1, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 100-240V C20 input, Bottom/Bottom Entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Sense None 1.75 x 49.5 x 2.25 in. (45.0 x 1258.0 x 58.0 mm.) 0U Vertical PRO1 PIPS false STV-2001C Metered 30 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Metered PDU, 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 208-240V 30A, NEMA L6-30P Plug, 10ft(3m) Cord w/ Power Pivot Cord Entry, Middle Display, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical None Current (A) false STV-2001K Metered 30 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Metered PDU, 0U, (24) IEC C13 + (6) IEC C19 Outlets, (1) LED Current Meter w/ Auto-flip, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 3m(10ft) Cord, w/ Power Pivot Cord Entry, Middle Display, Circuit Breakers None None 1.75 x 60.0 x 2.25 in. (45.0 x 1524.0 x 58.0 mm.) 0U Vertical None Current (A) false PTTS-H008-0-02M FSTS 8 3.3 208 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Sentry Fail Safe Transfer Switch, (8) IEC 60320 C13 Outlets, Input 100-120/208-230 VAC (20 Amp), 230 VAC (16 Amp), IEC 60320 C20 Inlet (Two Input Cords Ordered Separately), STI Black Paint None None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal None None false PTTS-H008-O-02M FSTS 8 1.9 120 16 16 1-Phase (L-L) IEC C20 100-240V Inlet Sentry Fail Safe Transfer Switch, (8) IEC 60320 C13 Outlets, Input 100-120/208-240 VAC (20 Amp), 230 VAC (16 Amp), IEC 60320 C20 Inlet (Two Input Cords Ordered Separately), STI Black Paint None None 17.2 x 1.75 x 7.0 in. (437.0 x 45.0 x 178.0 mm.) 1U Horizontal None None false CB-12H1-C20 Basic 12 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet Basic PDU, 12 NEMA 5-20R outlets, 120V w/ C20 Inlet (Input power cord ordered separately) None None 17.0 x 1.75 x 2.25 in. (432.0 x 45.0 x 58.0 mm.) 1U Horizontal None None false CB-12H2-L630 Basic 12 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Basic PDU, 12 IEC C13 outlets, 208-240V w/ L6-30P connector & cord, 9.5ft (2.9m) None None 17.0 x 1.75 x 2.25 in. (432.0 x 45.0 x 58.0 mm.) 1U Horizontal None None false CB-26VOAE01F6 Basic 26 1.9 120 16 16 1-Phase (L-N) IEC C20 100-240V Inlet Basic PDU, (24) IEC C13 + (2) IEC C19 Outlets, 120V, 200-240V, 230V, 16A, IEC C20 Inlet, Bottom/Front Cord Entry, Doghouse Circuit Breakers (Input Cord Must Be Ordered Separately) None None 1.75 x 35.5 x 3.39 in. (45.0 x 902.0 x 87.0 mm.) 0U Vertical None None false CB-12H2-C20 Basic 12 3.3 208 20 16 1-Phase (L-L) IEC C20 200-240V Inlet Basic PDU, 12 IEC C13 outlets, 208-240V w/ C20 inlet (Input power cord ordered separately) None None 17.0 x 1.75 x 2.25 in. (432.0 x 45.0 x 58.0 mm.) 1U Horizontal None None false C1W24VS-1AFA25A5 Switched 24 1.9 120 20 16 1-Phase (L-N) IEC C20 100-120V Inlet PRO1 Switched PDU with PIPS (Per Input Power Sensing), 0U, 24 x NEMA 5-20R Outlets, (1) Input LED Amp Meter in the middle of the unit, 100-120V 20A (North America) 16A (Int'l) IEC C20 Inlet, Bottom/Front Cord Entry, (2) Temp/Humidity Sensor Capable, Fuses (Power Cord Sold Separately) Sense None 1.75 x 65.5 x 3.0 in. (45.0 x 1664.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false CB-12H1-L530 Basic 12 2.8 120 30 24 1-Phase (L-N) NEMA L5-30P Basic PDU, 12 NEMA 5-20R outlets, 120V w/ L5-30P connector & cord, 10ft (3m) None None 17.2 x 1.75 x 2.25 in. (437.0 x 45.0 x 58.0 mm.) 1U Horizontal None None false STV-3534A Smart 30 11.5 415 20 16 3-Phase Wye (L-N) NEMA L22-20P PRO1 Smart Primary PIPS, 0U, 30 Outlets (24xC13 + 6xC19), 415V 3PH Wye 20A NEMA L22-20P Plug, 3m (10ft) Power Pivot, Mid Display, 10KAIC Doghouse Breakers, Phase Monitoring None None 1.75 x 70.1 x 3.0 in. (45.0 x 1781.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false STV-3534C Smart 30 11.5 415 20 16 3-Phase Wye (L-N) 240/415V Wye 20A IEC 60309 3P+N+G 6Hr PRO1 Smart Primary PIPS, 0U, 30 Outlets (24xC13 + 6xC19), 415V 3PH Wye 20A IEC 60309 3P+N+E 6Hr Red Plug, 3m (10ft) Power Pivot, Mid Display, 10KAIC Doghouse Breakers, Phase Monitoring None None 1.75 x 70.1 x 3.0 in. (45.0 x 1781.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false STV-3534D Smart 30 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr PRO1 Smart Primary PIPS, 0U, 30 Outlets (24xC13 + 6xC19), 415V 3PH Wye 30A IEC 60309 3P+N+E 6Hr Red Plug, 3m (10ft) Power Pivot, Mid Display, 10KAIC Doghouse Breakers, Phase Monitoring None None 1.75 x 70.1 x 3.0 in. (45.0 x 1781.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false STV-3534J Smart 30 11.0 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr PRO1 Smart Primary PIPS, 0U, 30 Outlets (24xC13 + 6xC19), 400V 3PH Wye 16A IEC 60309 3P+N+E 6Hr Red Plug, 3m (10ft) Power Pivot, Mid Display, 10KAIC Doghouse Breakers, Phase Monitoring None None 1.75 x 70.1 x 3.0 in. (45.0 x 1781.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false STV-3534K Smart 30 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr PRO1 Smart Primary PIPS, 0U, 30 Outlets (24xC13 + 6xC19), 400V 3PH Wye 32A IEC 60309 3P+N+E 6Hr Red Plug, 3m (10ft) Power Pivot, Mid Display, 10KAIC Doghouse Breakers, Phase Monitoring None None 1.75 x 70.1 x 3.0 in. (45.0 x 1781.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false STV-3534Z Smart 30 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P PRO1 Smart Primary PIPS, 0U, 30 Outlets (24xC13 + 6xC19), 415V 3PH Wye 30A NEMA L22-30P Plug, 3m (10ft) Power Pivot, Mid Display, 10KAIC Doghouse Breakers, Phase Monitoring None None 1.75 x 70.1 x 3.0 in. (45.0 x 1781.0 x 77.0 mm.) 0U Vertical PRO1 PIPS false