Model # Type Total Outlets Input Power Capacity Input Nominal Voltage Input Current Input Current Rated Phase Plug Type Description Branch Monitoring Outlet Monitoring Dimensions Mounting PDU Platform Input Monitoring Alt Phase C4G36RA-GNBD2FE1 Switched POPS 36 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 20A (16A Rated) IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-GPBD2FE1 Switched POPS 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 380/400/415V 3PH 3-Phase Wye 30A (24A Rated for North America/Canada)/32A IEC 60309 3P+N+G 6hr Plug with 3 m (9.84 ft) Globally Rated UL CSA CE Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-DFBD2FE1 Switched POPS 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 50A (40A Rated) CS8365 Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-DQBD2FE1 Switched POPS 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 208-240V 3-phase 60A (48A Rated) IEC 60309 3P+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4G36RA-YQBD2FE1 Switched POPS 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS PRO4X iX PDU, 36 RamLock HDOT Outlets (12 C13 + 24 Cx), 120/208V 3-phase 60A (48A Rated) IEC 60309 3P+N+G 9Hr Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 1.78m (70 in.) Current (A) POPS 2.2 x 70.0 x 3.07 in. (56.0 x 1778.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-0ABE2FD7 Smart 48 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 120-240V 20A (16A) IEC C20 Inlet, Bottom/Angled Cord Entry (Input Cord Not Included and Must Be Specified Separately), Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-2BBE2FD7 Smart 48 3.3 208 20 16 1-Phase (L-L) NEMA L6-20P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 20A (16A Rated) NEMA L6-20P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C4S48RA-2CBE2FD7 Smart 48 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PRO4X iX PDU, 48 RamLock HDOT Outlets (24 C13 + 24 Cx), 208V 30A (24A Rated) NEMA L6-30P Plug with 3 m (9.84 ft) Input Cord, Bottom/Angled Cord Entry, Outlet #1 Opposite The Power Input, Auto-orient Middle LCD, Dual 10/100/1000 Mbps Ethernet Ports, Environmental Sensor Support, Dual USB-A Ports for Linking and Accessories, Height 2.03m (80 in.) Current (A) None 2.2 x 80.0 x 3.07 in. (56.0 x 2032.0 x 78.0 mm.) 0U Vertical PRO4X PIPS true C3WG36RL-EPJE2MT4 Switched POPS 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 230V/1-Phase (L-N)/32A, Input: IEC 230V/32A 2P+PE 6Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-DQJE2MT2 Switched POPS 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/60A, Input: 208V Delta 60A IEC 60309 3P+G 9Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-YCJE2MT3 Switched POPS 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Wye (L-L)/30A, Input: NEMA L21-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-GPJE2MT2 Switched POPS 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 415V/3-Phase Wye (L-N)/30A, Input: 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3B36RL-YCJE0AT3 Basic 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208V/3-Phase Wye (L-L)/30A, Input: NEMA L21-30P, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3B36RL-GPJE0AT2 Basic 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 415V/3-Phase Wye (L-N)/30A, Input: 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3B36RL-DQJE0AT2 Basic 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208V/3-Phase Delta (L-L)/60A, Input: 208V Delta 60A IEC 60309 3P+G 9Hr, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3S36RL-EPJE2MT4 Smart 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 230V/1-Phase (L-N)/32A, Input: IEC 230V/32A 2P+PE 6Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3S36RL-YCJE2MT3 Smart 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Wye (L-L)/30A, Input: NEMA L21-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3B36RL-EPJE0AT4 Basic 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 230V/1-Phase (L-N)/32A, Input: IEC 230V/32A 2P+PE 6Hr, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3S36RL-GPJE2MT2 Smart 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 415V/3-Phase Wye (L-N)/30A, Input: 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3S36RL-DQJE2MT2 Smart 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/60A, Input: 208V Delta 60A IEC 60309 3P+G 9Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-2CJE2MT4 Switched POPS 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/30A, Input: NEMA L6-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-0AJE2MT4 Switched POPS 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers, Input Cord (PTCORD-Lx) Ordered Separately Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-DFJE2MT2 Switched POPS 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/50A, Input: CS8365 3P+G 50A, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-YQJE2MT2 Switched POPS 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Wye (L-L)/60A, Input: 208V Wye 60A IEC 60309 3P+N+G 9Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-YCJE2MT3 Switched 36 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Wye (L-L)/30A, Input: NEMA L21-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-DCJE2MT3 Switched 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/30A, Input: NEMA L15-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-DCJE2MT3 Switched POPS 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/30A, Input: NEMA L15-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-5CJE2MT2 Switched POPS 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 415V/3-Phase Wye (L-N)/30A, Input: NEMA L22-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-5CJE2MT2 Switched 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 415V/3-Phase Wye (L-N)/30A, Input: NEMA L22-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-GPJE2MT2 Switched 36 17.3 415 30 24 3-Phase Wye (L-N) 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 415V/3-Phase Wye (L-N)/30A, Input: 230/400 32A & 240/415V Wye 30A IEC 60309 3P+N+G 6Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3B36RL-DCJE0AT3 Basic 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208V/3-Phase Delta (L-L)/30A, Input: NEMA L15-30P, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3W36RL-DFJE2MT2 Switched 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/50A, Input: CS8365 3P+G 50A, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-YQJE2MT2 Switched 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Wye (L-L)/60A, Input: 208V Wye 60A IEC 60309 3P+N+G 9Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-DQJE2MT2 Switched 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/60A, Input: 208V Delta 60A IEC 60309 3P+G 9Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3B36RL-5CJE0AT2 Basic 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 415V/3-Phase Wye (L-N)/30A, Input: NEMA L22-30P, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3B36RL-DFJE0AT2 Basic 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208V/3-Phase Delta (L-L)/50A, Input: CS8365 3P+G 50A, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3B36RL-YQJE0AT2 Basic 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208V/3-Phase Wye (L-L)/60A, Input: 208V Wye 60A IEC 60309 3P+N+G 9Hr, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3S36RL-2CJE2MT4 Smart 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/30A, Input: NEMA L6-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3S36RL-0AJE2MT4 Smart 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers, Input Cord (PTCORD-Lx) Ordered Separately Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3S36RL-DCJE2MT3 Smart 36 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/30A, Input: NEMA L15-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3B36RL-2CJE0AT4 Basic 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208-240V/1-Phase (L-L)/30A, Input: NEMA L6-30P, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3B36RL-0AJE0AT4 Basic 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet (Bottom/End), Circuit Breakers, Input Cord (PTCORD-Lx) Ordered Separately None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3S36RL-5CJE2MT2 Smart 36 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 415V/3-Phase Wye (L-N)/30A, Input: NEMA L22-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3S36RL-YQJE2MT2 Smart 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Wye (L-L)/60A, Input: 208V Wye 60A IEC 60309 3P+N+G 9Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-EPJE2MT4 Switched 36 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 230V/1-Phase (L-N)/32A, Input: IEC 230V/32A 2P+PE 6Hr, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-2CJE2MT4 Switched 36 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/30A, Input: NEMA L6-30P, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3W36RL-0AJE2MT4 Switched 36 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/1-Phase (L-L)/20A, Input: IEC C20 100-240V Inlet (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers, Input Cord (PTCORD-Lx) Ordered Separately Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3WG36RL-4NJE2MT2 Switched POPS 36 11.0 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Switched POPS PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 400V/3-Phase Wye (L-N)/16A, Input: 400V 3PH Wye 16A 60309 3P+N+PE, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) POPS 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C3B36RL-GNJE0AT2 Basic 36 11.5 415 20 16 3-Phase Wye (L-N) 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr Basic, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), 415V/3-Phase Wye (L-N)/20A, Input: 230/400 16A & 240/415V Wye 20A IEC 60309 3P+N+G 6Hr, 3m (10ft) Cord (Bottom/End), Circuit Breakers None None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X None false C3S36RL-DFJE2MT2 Smart 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart PRO3X with PIPS, 0U, 36 RamLock HDOT Outlets (18 C13 + 18 Cx), Color Matrix LCD, 208V/3-Phase Delta (L-L)/50A, Input: CS8365 3P+G 50A, 3m (10ft) Cord (Enters From End of the PDU, Outlet Number 1 Starts On the End Opposite Power Cord), Middle Display/Network, Dual 10/100/1000 Mbps Ethernet Ports, Support for Raritan DX2 Sensors, Circuit Breakers Current (A) None 2.2 x 70.0 x 3.19 in. (56.0 x 1778.0 x 82.0 mm.) 0U Vertical PRO3X PIPS false C2W48TE-DFME2M99 Switched 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched Primary PRO2 30xC13+18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 50A CS8365 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W48TE-YQME2M99 Switched 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched Primary PRO2 30xC13+18xCx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG48TE-DFME2M99 Switched POPS 48 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS Primary PRO2 30xC13+18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 50A CS8365 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG48TE-YQME2M99 Switched POPS 48 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS Primary PRO2 30xC13+18xCx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S24SP-YBLN5D6 Smart 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Smart PIPS PRO2 Primary, 2U, (18) HDOT IEC C13 + (6) HDOT Cx Outlets Alt-phase, Input Amp Meter, 208V Wye 20A, NEMA L21-20P, 10 ft (3m) Input Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Current (A) None 17.2 x 3.5 x 10.0 in. (437.0 x 89.0 x 254.0 mm.) 2U Horizontal PRO2 PIPS true C2S24SP-DBLN5D6 Smart 24 5.7 208 20 16 3-Phase Delta (L-L) NEMA L15-20P Smart PIPS PRO2 Primary, 2U, (18) HDOT IEC C13 + (6) HDOT Cx Outlets Alt Phase, Input Amp Meter, 208V Delta 20A, NEMA L15-20P, 10 ft (3m) Input Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Current (A) None 17.2 x 3.5 x 10.0 in. (437.0 x 89.0 x 254.0 mm.) 2U Horizontal PRO2 PIPS true C2S24SP-YCLN5D6 Smart 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart PIPS PRO2 Primary, 2U, (18) HDOT IEC C13 + (6) HDOT Cx Outlets Alt-phase, Input Amp Meter, 208V Wye 30A, NEMA L21-30P, 10 ft (3m) Input Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Current (A) None 17.2 x 3.5 x 10.0 in. (437.0 x 89.0 x 254.0 mm.) 2U Horizontal PRO2 PIPS true C2S24SP-DCLN5D6 Smart 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart PIPS PRO2 Primary, 2U, (18) HDOT IEC C13 + (6) HDOT Cx Outlets Alt-phase, Input Amp Meter, 208V Delta 30A, NEMA L15-30P, 10 ft (3m) Input Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Current (A) None 17.2 x 3.5 x 10.0 in. (437.0 x 89.0 x 254.0 mm.) 2U Horizontal PRO2 PIPS true C2WG24SN-DCLN5D6 Switched POPS 24 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched PRO2 POPS PIPS, 2U, 24 HDOT Outlets (18xC13 + 6xCx), Input Amp Meters, 208V 3-Phase 30A, NEMA L15-30P, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-EPJN5D6 Switched POPS 24 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched PRO2 POPS PIPS, 2U, 18 C13 + 6 Cx HDOT Outlets, Input Amp Meters, 230V 1-Phase 32A, IEC 60309, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG12SM-0AJA2D3 Switched POPS 12 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched POPS PRO2, 1U, (12) HDOT Outlets (9xC13 + 3xCx), Input Amp Meter, 120/208-240 20A and 230V 16A Rating w/ IEC C20 Inlet, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection, Input PTCORD-Lx power cord ordered separately Current (A) POPS 17.2 x 1.75 x 11.57 in. (437.0 x 45.0 x 294.0 mm.) 1U Horizontal PRO2 PIPS false C2WG12SM-EPJA2D3 Switched POPS 12 7.3 230 32 32 1-Phase (L-N) IEC 230V/32A 2P+PE 6Hr Switched POPS PRO2, 1U, (12) HDOT (9xC13 + 3xCx), Input Amp Meter, 230V 32A with IEC 60309 2P+G Plug, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 1.75 x 11.57 in. (437.0 x 45.0 x 294.0 mm.) 1U Horizontal PRO2 PIPS false C2WG12SM-2CJA2D3 Switched POPS 12 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched POPS PRO2, 1U, 12 Outlets (9xIEC C13 + 3xCx HDOT), Input Amp Meter, 208-240V 30A with NEMA L6-30P, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 1.75 x 11.57 in. (437.0 x 45.0 x 294.0 mm.) 1U Horizontal PRO2 PIPS false C2WG24SN-2CJN5D6 Switched POPS 24 5.0 208 30 24 1-Phase (L-L) NEMA L6-30P Switched PRO2 POPS PIPS, 2U, (18 C13 + 6 Cx) HDOT Outlets, Input Amp Meters, 200-240V 30A, NEMA L6-30P, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-YCLN5D6 Switched POPS 24 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched PRO2 POPS PIPS, 2U, 24 HDOT Outlets (18xC13 + 6xCx), Input Amp Meters, 208V 3-Phase 30A, NEMA L21-30P, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-4NJN5D6 Switched POPS 24 11.0 400 16 16 3-Phase Wye (L-N) 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr Switched PRO2 POPS PIPS, 2U, 18xC13 + 6xCx HDOT Outlets, Input Amp Meters, 230/400V 3-Phase 16A, IEC 60309 16A 3P+N+G, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-5PJN5D6 Switched POPS 24 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched PRO2 POPS PIPS, 2U, 18xC13 + 6xCx HDOT Outlets, Input Amp Meters, 240/415V 3-Phase 30A, IEC 60309 30A 3P+N+G, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-4PJN5D6 Switched POPS 24 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Switched PRO2 POPS PIPS, 2U, 18xC13 + 6xCx HDOT Outlets, Input Amp Meters, 230/400V 3-Phase 32A, IEC 60309 32A 3P+N+G, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-0AJN5D6 Switched POPS 24 3.3 208 20 16 1-Phase (L-L) IEC C20 100-240V Inlet Switched PRO2 POPS PIPS, 2U, (18 C13 + 6 Cx) HDOT Outlets, Input Amp Meters, 120/208-240 20A and 230V 16A Rating w/ IEC C20 Inlet, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection ** Input PTCORD-Lx power cord ordered separately ** Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-YBLN5D6 Switched POPS 24 5.7 208 20 16 3-Phase Wye (L-L) NEMA L21-20P Switched PRO2 POPS PIPS, 2U, 24 HDOT Outlets(18 x C13, 6 x Cx), Input Amp Meters, 208V 3-Phase 20A, NEMA L21-20P, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG24SN-5CJN5D6 Switched POPS 24 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched PRO2 POPS PIPS, 2U, 18xC13 + 6xCx HDOT Outlets, Input Amp Meters, 240/415V 3-Phase 30A, NEMA L22-30P, 10 ft (3.04 m) Input Cord, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Current (A) POPS 17.2 x 3.5 x 17.5 in. (437.0 x 89.0 x 445.0 mm.) 2U Horizontal PRO2 PIPS false C2WG48TE-5PAE2M99 Switched POPS 48 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Switched POPS Primary PRO2 (30xC13 + 18xCx) Alt Phase HDOT Outlets, 415V 3PH Wye 6BR 30A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Base Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S48TE-5PAE2M99 Smart 48 17.3 415 30 24 3-Phase Wye (L-N) 240/415V Wye 30A IEC 60309 3P+N+G 6Hr Smart Primary PRO2 (30xC13 + 18xCx) Alt Phase HDOT Outlets, 415V 3PH Wye 6BR 30A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Base Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG48TE-DQME2M99 Switched POPS 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched POPS Primary PRO2 30xC13+18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 60A 60309 3P+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG48TE-DQME2M99 Smart POPS 48 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Smart POPS Primary PRO2 30xC13+18xCx IEC C13 Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 60A 60309 3P+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Base Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG24TB-4QCD27T0 Switched POPS 24 43.4 400 63 63 3-Phase Wye (L-N) 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr Switched PRO2 POPS PIPS PDU, (24) HDOT Cx, 230V/400V 3Ph 63A, IEC 60309 3P+N+E, 6Hr Red IP44 Plug, 3.04m (10ft), Bottom Cord Entry, Middle Display, Alt-Branch, 5 kAIC Flush Breakers, Non-cancellable, Non-refundable Current (A) POPS 2.2 x 70.0 x 3.56 in. (56.0 x 1778.0 x 91.0 mm.) 0U Vertical PRO2 PIPS false C2WG24TB-5QCD27T0 Switched POPS 24 34.5 415 60 48 3-Phase Wye (L-N) 240/415V Wye 60A IEC 60309 3P+N+G 6Hr **Custom** Switched PRO2 POPS PIPS PDU, (24) Cx HDOT, 240V/415V 3Ph 60A, IEC 60309 3P+N+E, 6Hr Red, 3.04m (10ft), Bottom Cord Entry, Middle Display, Alt-Branch, 10 kAIC Flush Breakers, Non-cancellable, Non-returnable Current (A) POPS 2.2 x 70.0 x 3.56 in. (56.0 x 1778.0 x 91.0 mm.) 0U Vertical PRO2 PIPS false C2W36TE-DQME2M99 Switched 36 17.3 208 60 48 3-Phase Delta (L-L) 208V Delta 60A IEC 60309 3P+G 9Hr Switched Primary PRO2 18xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A 60309 3P+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S48TE-YCMFAM99 Smart 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets plus (3) NEMA 5-15/20P Utility Outlets, 208V 3PH Wye 30A L21-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S48TE-DCMFAM99 Smart 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 30A L15-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG48TE-DCMFAM99 Smart POPS 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Smart POPS Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 30A L15-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG48TE-YCMFAM99 Smart POPS 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Smart POPS Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets plus (3) NEMA 5-15/20P Utility Outlets, 208V 3PH Wye 30A L21-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W48TE-YCMFAM99 Switched 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets plus (3) NEMA 5-15/20P Utility Outlets, 208V 3PH Wye 30A L21-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W48TE-DCMFAM99 Switched 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 30A L15-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG48TE-YCMFAM99 Switched POPS 48 8.6 208 30 24 3-Phase Wye (L-L) NEMA L21-30P Switched POPS Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets plus (3) NEMA 5-15/20P Utility Outlets, 208V 3PH Wye 30A L21-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG48TE-DCMFAM99 Switched POPS 48 8.6 208 30 24 3-Phase Delta (L-L) NEMA L15-30P Switched POPS Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 30A L15-30P 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S36TE-DFME2M99 Smart 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart Primary PRO2 18xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 50A CS8365 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S36TE-YQME2M99 Smart 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart Primary PRO2 18xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG36TE-DFME2M66 Smart POPS 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Smart POPS Primary PRO2 24xC13+12xCx Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 50A CS8365 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG36TE-YQME2M66 Smart POPS 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Smart POPS Primary PRO2 24xC13+12xCx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A IEC60309 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W36TE-DFME2M99 Switched 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched PIPS PRO2, Per Input Power Sensing, 0U, 18xC13 + 18xCx Alt-Phase HDOT, (3) LED Amp Meter in the Middle, 3-phase 208V, 50A with CS8365, Bottom/Base Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W36TE-YQME2M99 Switched 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched Primary PRO2 18xC13 + 18xCx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG36TE-DFME2M66 Switched POPS 36 14.4 208 50 40 3-Phase Delta (L-L) CS8365 3P+G 50A Switched POPS Primary PRO2 (24) C13 and (12) Cx Alt Phase HDOT Outlets, 208V 3PH Delta 6BR 50A CS8365 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2WG36TE-YQME2M66 Switched POPS 36 17.3 208 60 48 3-Phase Wye (L-L) 208V Wye 60A IEC 60309 3P+N+G 9Hr Switched POPS Primary PRO2 (24) C13 and (12) Cx Alt Phase HDOT Outlets, 208V 3PH Wye 6BR 60A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, WxD = 2.20in x 2.50in Current (A) Determined By Outlet Module 2.2 x 70.0 x 3.0 in. (56.0 x 1778.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S48TE-4PAE2M99 Smart 48 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 400V 3PH Wye 6BR 32A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2S48TE-5CAE2M99 Smart 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Smart Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 415V 3PH Wye 6BR 30A L22-30 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG48TE-4PAE2M99 Smart POPS 48 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Smart POPS Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 400V 3PH Wye 6BR 32A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2SG48TE-5CAE2M99 Smart POPS 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Smart POPS Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 415V 3PH Wye 6BR 30A L22-30 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W48TE-4PAE2M99 Switched 48 22.0 400 32 32 3-Phase Wye (L-N) 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr Switched Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 400V 3PH Wye 6BR 32A 60309 3P+N+PE 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true C2W48TE-5CAE2M99 Switched 48 17.3 415 30 24 3-Phase Wye (L-N) NEMA L22-30P Switched Primary PRO2 30xC13 + 18xCx Alt Phase HDOT Outlets, 415V 3PH Wye 6BR 30A L22-30 3m/10ft cord, Auto-Orient Mid Display, Bottom Cord Entry, Doghouse Breakers, Phase Monitoring, LxWxD = 80.0x2.20x2.50 in. (2032x56x64 mm) Current (A) Determined By Outlet Module 2.2 x 80.0 x 3.0 in. (56.0 x 2032.0 x 77.0 mm.) 0U Vertical PRO2 PIPS true