Request For Quote | Model # | Type | Total Outlets | Power Capacity kW | Voltage | Current (A) | Current Rated (A) | Phase | Plug Type | Description | Branch Monitoring | Outlet Monitoring | Dimensions | Mounting | PRO2 | Input Monitoring | Alt Phase |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C2W48TE-DFME2M99 | Switched | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched Master PRO2 30xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W48TE-YQME2M99 | Switched | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched Master PRO2 30xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG48TE-DFME2M99 | Switched POPS | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG48TE-YQME2M99 | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C1S10SA-2CBA2B4 | Smart | 10 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Master PRO1 PIPS PDU,... | None | None | 1U Horizontal | PIPS | false | |||
C1S10SA-EPBA2B4 | Smart | 10 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart Master PRO1 PIPS PDU,... | None | None | 1U Horizontal | PIPS | false | |||
C2S24SP-YBLN5D6 | Smart | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Smart PIPS PRO2 Master, 2U,... | Current (A) | None | 2U Horizontal | PIPS | true | |||
C2S24SP-DBLN5D6 | Smart | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Smart PIPS PRO2 Master, 2U,... | Current (A) | None | 2U Horizontal | PIPS | true | |||
C2S24SP-YCLN5D6 | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart PIPS PRO2 Master, 2U,... | Current (A) | None | 2U Horizontal | PIPS | true | |||
C2S24SP-DCLN5D6 | Smart | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart PIPS PRO2 Master, 2U,... | Current (A) | None | 2U Horizontal | PIPS | true | |||
C1S24SP-0AAA4A6 | Smart | 24 | 3.3 | 208 | 16 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Smart PIPS PRO1, 2U, (18) H... | None | None | 2U Horizontal | PIPS | false | |||
C1S24SP-EPAA4A6 | Smart | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart PIPS PRO1, 2U, (18) H... | None | None | 2U Horizontal | PIPS | false | |||
C1S24SP-2CAA4A6 | Smart | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart PIPS PRO1, 2U, (18) H... | None | None | 2U Horizontal | PIPS | false | |||
C2WG24SN-DCLN5D6 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 POPS PIPS, 2U... | Current (A) | POPS | 2U Horizontal | PIPS | false | |||
C2WG24SN-EPJN5D6 | Switched POPS | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO2 POPS PIPS, 2U... | Current (A) | POPS | 2U Horizontal | PIPS | false | |||
C2WG12SM-0AJA2D3 | Switched POPS | 12 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched POPS PRO2, 1U, (12... | Current (A) | POPS | 1U Horizontal | PIPS | false | |||
C2WG12SM-EPJA2D3 | Switched POPS | 12 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched POPS PRO2, 1U, (12... | Current (A) | POPS | 1U Horizontal | PIPS | false | |||
C2WG12SM-2CJA2D3 | Switched POPS | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS PRO2, 1U, 12 ... | Current (A) | POPS | 1U Horizontal | PIPS | false | |||
C2WG12SM-E2JA2D3 | Switched POPS | 12 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | Unterminated | Switched POPS PRO2, 1U, (12... | Current (A) | POPS | 1U Horizontal | PIPS | false | |||
C2WG24SN-2CJN5D6 | Switched POPS | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO2 POPS PIPS, 2U... | Current (A) | POPS | 2U Horizontal | PIPS | false | |||
C2WG24SN-YCLN5D6 | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 POPS PIPS, 2U... | Current (A) | POPS | 2U Horizontal | PIPS | false | |||
C2S48TE-YCMFAM99 | Smart | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Master PRO2 30xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S48TE-DCMFAM99 | Smart | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Master PRO2 30xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG48TE-DCMFAM99 | Smart POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Master PRO2 30xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG48TE-YCMFAM99 | Smart POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Master PRO2 30xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W48TE-YCMFAM99 | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched Master PRO2 30xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W48TE-DCMFAM99 | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched Master PRO2 30xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG48TE-YCMFAM99 | Switched POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG48TE-DCMFAM99 | Switched POPS | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S36TE-DFME2M99 | Smart | 36 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart Master PRO2 18xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S36TE-YQME2M99 | Smart | 36 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart Master PRO2 18xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36TE-DFME2M66 | Smart POPS | 36 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart POPS Master PRO2 24xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36TE-YQME2M66 | Smart POPS | 36 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart POPS Master PRO2 24xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W36TE-DFME2M99 | Switched | 36 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PIPS PRO2, Per Inp... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W36TE-YQME2M99 | Switched | 36 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched Master PRO2 18xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36TE-DFME2M66 | Switched POPS | 36 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36TE-YQME2M66 | Switched POPS | 36 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S48TE-4PAE2M99 | Smart | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart Master PRO2 30xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S48TE-5CAE2M99 | Smart | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart Master PRO2 30xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG48TE-4PAE2M99 | Smart POPS | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart POPS Master PRO2 30xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG48TE-5CAE2M99 | Smart POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart POPS Master PRO2 30xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W48TE-4PAE2M99 | Switched | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched Master PRO2 30xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W48TE-5CAE2M99 | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Master PRO2 30xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG48TE-4PAE2M99 | Switched POPS | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG48TE-5CAE2M99 | Switched POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C1S39TS-5CPD2T444 | Smart | 39 | 17.3 | 415 | 30 | 30 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart PRO1 Master PIPS, 39 ... | None | None | 0U Vertical | PIPS | false | |||
C1S39TS-4PPD2T444 | Smart | 39 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart PRO1 Master PIPS, 39 ... | None | None | 0U Vertical | PIPS | false | |||
C2S39TS-2CBA2S444 | Smart | 39 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Master PRO2 PIP, 39 H... | Current (A) | None | 0U Vertical | PIPS | false | |||
C2S39TS-EPBA2S444 | Smart | 39 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart Master PRO2 PIP, 39 H... | Current (A) | None | 0U Vertical | PIPS | false | |||
C2S39TS-YCBA2S444 | Smart | 39 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Master PRO2 PIPS, 39 ... | Current (A) | None | 0U Vertical | PIPS | false | |||
C2S39TS-DCBA2S444 | Smart | 39 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Master PRO2 PIPS, 39 ... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1S13TS-0ABA154 | Smart | 13 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Smart Master Pro1 PIPS Vert... | None | None | 0U Vertical | PIPS | false | |||
C1S13TS-2CBA154 | Smart | 13 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Master Pro1 PIPS Vert... | None | None | 0U Vertical | PIPS | false | |||
C1S13TS-EPBA154 | Smart | 13 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart Master Pro1 PIPS Vert... | None | None | 0U Vertical | PIPS | false | |||
C1S13TS-OABA154 | Smart | 13 | 1.9 | 120 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Smart Master Pro1 PIPS Vert... | None | None | 0U Vertical | PIPS | false | |||
C1S24TB-4QAE2566 | Smart | 24 | 43.4 | 400 | 63 | 63 | 3-Phase Wye (L-N) | 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr | Smart Master PRO1 12xC13 + ... | None | None | 0U Vertical | PIPS | true | |||
C1S24TB-4QAE2766 | Smart | 24 | 43.4 | 400 | 63 | 63 | 3-Phase Wye (L-N) | 230/400V Wye 63A IEC 60309 3P+N+PE 6Hr | Smart Master PRO1 12xC13 + ... | None | None | 0U Vertical | PIPS | true | |||
C1S24TB-5QAE2566 | Smart | 24 | 34.5 | 415 | 60 | 48 | 3-Phase Wye (L-N) | 240/415V Wye 60A IEC 60309 3P+N+G 6Hr | Smart Master PRO1 12xC13 + ... | None | None | 0U Vertical | PIPS | true | |||
C1S24TB-5QAE2766 | Smart | 24 | 34.5 | 415 | 60 | 48 | 3-Phase Wye (L-N) | 240/415V Wye 60A IEC 60309 3P+N+G 6Hr | Smart Master PRO1 12xC13 + ... | None | None | 0U Vertical | PIPS | true | |||
C2S36TE-2CAF2M99 | Smart | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart Master PRO2 (36) Alt-... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2S36TE-2QAF2M99 | Smart | 36 | 10.0 | 208 | 60 | 48 | 1-Phase (L-L) | IEC 208V/60A 2P+G 6Hr | Smart Master PRO2 (36) Alt-... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2S36TE-EPAF2M99 | Smart | 36 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart Master PRO2 (36) Alt-... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2S36TE-EQAF2M99 | Smart | 36 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Smart Master PRO2 (36) Alt-... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2SG36TE-2CAF2M66 | Smart POPS | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart POPS Master PRO2 (36)... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2SG36TE-2QAF2M66 | Smart POPS | 36 | 10.0 | 208 | 60 | 48 | 1-Phase (L-L) | IEC 208V/60A 2P+G 6Hr | Smart POPS Master PRO2 (36)... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2SG36TE-EPAF2M66 | Smart POPS | 36 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart POPS Master PRO2 (36)... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2SG36TE-EQAF2M66 | Smart POPS | 36 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Smart POPS Master PRO2 (36)... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2W36TE-2CAF2M99 | Switched | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched Master PRO2 (36) A... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2W36TE-2QAF2M99 | Switched | 36 | 10.0 | 208 | 60 | 48 | 1-Phase (L-L) | IEC 208V/60A 2P+G 6Hr | Switched Master PRO2 (36) A... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2W36TE-EPAF2M99 | Switched | 36 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched Master PRO2 (36) A... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2W36TE-EQAF2M99 | Switched | 36 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Switched Master PRO2 (36) A... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2WG36TE-2CAF2M66 | Switched POPS | 36 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2WG36TE-2QAF2M66 | Switched POPS | 36 | 10.0 | 208 | 60 | 48 | 1-Phase (L-L) | IEC 208V/60A 2P+G 6Hr | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2WG36TE-EPAF2M66 | Switched POPS | 36 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2WG36TE-EQAF2M66 | Switched POPS | 36 | 11.0 | 230 | 63 | 48 | 1-Phase (L-N) | IEC 230V/63A 2P+PE 6Hr | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | false | |||
C2S36TE-DCMFAM99 | Smart | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Master PRO2 18xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S36TE-YCMFAM99 | Smart | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Master PRO2 18xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36TE-DCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Master PRO2 24xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36TE-YCMFAM66 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Master PRO2 24xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W36TE-DCMFAM99 | Switched | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2, Per Input Po... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W36TE-YCMFAM99 | Switched | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched Master PRO2 18xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36TE-DCMFAM66 | Switched POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36TE-YCMFAM66 | Switched POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S36TE-4PAE2M99 | Smart | 36 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart Master PRO2 18xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S36TE-5CAE2M99 | Smart | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart Master PRO2 18xC13 + ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36TE-4PAE2M66 | Smart POPS | 36 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Smart POPS Master PRO2 24xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36TE-5CAE2M66 | Smart POPS | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Smart POPS Master PRO2 24xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W36TE-4PAE2M99 | Switched | 36 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched Master PRO2 18xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2W36TE-5CAE2M99 | Switched | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched Master PRO2 18xC13... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36TE-4PAE2M66 | Switched POPS | 36 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36TE-5CAE2M66 | Switched POPS | 36 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched POPS Master PRO2 (... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S48TE-YQME2M99 | Smart | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart Master PRO2 30xC13+18... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S48TE-DFME2M99 | Smart | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart Master PRO2 30xC13+18... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG48TE-DFME2M99 | Smart POPS | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Smart POPS Master PRO2 30xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG48TE-YQME2M99 | Smart POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Smart POPS Master PRO2 30xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2WG36CE-DCMFAM00 | Switched POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS Master PRO2 3... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36CE-DCMFAM00 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS Master PRO2 36xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2SG36CE-YCMFAM00 | Smart POPS | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS Master PRO2 36xC... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S36CE-YCMFAM66 | Smart | 36 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart Master PRO2 24xC13+12... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true | |||
C2S42CE-DCMFAM00 | Smart | 42 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart Master PRO2 (42) C13 ... | Current (A) | Determined By Outlet Module | 0U Vertical | PIPS | true |