1-800-835-1515
Model# CDU Type Description Mounting Voltage Phases Current Power Input Plug PIPS Total Outlets IEC C13 IEC C19 NEMA 5-20R BCP
C-10H1-C20M Metered Metered CDU, 1U, 10 x NEMA 5-20R Outlets, LED Amp Meter, 120V, 20A, C20 Inlet (Input power cord ordered separately), STI Black Horizontal 120 1 20 2.40 C20 No 10 0 0 10 None
C-10H1-L30M Metered Metered CDU, 1U, 10 x NEMA 5-20R Outlets, LED amp meter, 120V 30A input w/ NEMA L5-30P connector & cord, 10ft (3m), STI Black Paint Horizontal 120 1 30 3.60 L5-30P No 10 0 0 10 Fuses
C-12H2-C20M Metered Metered CDU, Horizontal Mount, 1U, 12 x IEC C13 Outlets, LED amp meter, 208V 20A w/ C20 Inlet, STI Black (Input power cord ordered separately) Horizontal 208 1 20 4.16 C20 No 12 12 0 0 None
C-12H2-L30M Metered Metered CDU, 1U, 12 IEC C13 Outlets, LED amp meter, 208V 30A input w L6-30P connector & cord, 10ft (3m) Horizontal 208 1 30 6.24 L6-30P No 12 12 0 0 Fuses
C-12HE-C20M Metered Metered CDU, 12 x IEC C13 outlets, LED amp meter, 230V 16A input w/ C20 inlet, Paint: STI Black Horizontal 230 1 16 3.68 C20 No 12 12 0 0 None
C-12HE-P32M Metered Metered CDU, 1U, 12 x IEC C13 Outlets, LED Amp Meter, 230V 32A Input w/ IEC 60309 32A Pin & Sleeve 'Commando' plug, Paint: STI Black Horizontal 230 1 32 7.36 IEC 60309 No 12 12 0 0 Fuses
C-12V1-C20M Metered Metered CDU, 0U, 12 x NEMA 5-20R outlets, LED amp meter, 120V, 20A, input w/ C20 inlet, STI Black (Input power cord sold separately) Vertical 120 1 20 2.40 C20 No 12 0 0 12 Fuses
C-12V1-L30M Metered Metered CDU, 0U, 12 x NEMA 5-20R outlets, LED amp meter, 120V, 30A input w/ L5-30P connector & cord, 10ft (3m), STI Black Vertical 120 1 30 3.60 L5-30P No 12 0 0 12 Fuses
C-12V2-C20M Metered Metered CDU, 0U, 12 x IEC C13 outlets, LED Amp Meter, 208V, 20A Input w/ C20 Inlet, STI Black (Input power cord sold separately) Vertical 208 1 20 4.16 C20 No 12 12 0 0 Fuses
C-12VE-C20M Metered Metered CDU, 0U, 12 x IEC C13 outlets, LED amp meter, 230V, 16A Input w/ C20 Inlet, STI Black Vertical 230 1 16 3.68 C20 No 12 12 0 0 Fuses
C-24H2-L30 Metered Metered CDU, 1U, 24 x IEC C13 Outlets, LED Amp Meter, 208V, 30A w/ L6-30P connector & cord, 10ft (3m) Horizontal 208 1 30 6.24 L6-30P No 24 24 0 0 Fuses
C-24HE-P32 Metered Metered CDU, 1U, 24 x IEC C13 Outlets, LED Amp Meter, 230V, 32A w/ 60309 32A cord Horizontal 230 1 32 7.36 IEC 60309 No 24 24 0 0 Fuses
C-24V1-C20M Metered Metered CDU, 0U, 24 x NEMA 5-20R Outlets, LED amp meter, 120V 20A input w/ C20 Inlet (Input power cord ordered separately), STI Black Vertical 120 1 20 2.40 C20 No 24 0 0 24 Fuses
C-24V1-L30M Metered Metered CDU, 0U, 24 x NEMA 5-20R Outlets, LED amp meter, 120V 30A input w/ NEMA L5-30P connector & cord, 10ft (3m), Color: STI Black Vertical 120 1 30 3.60 L5-30P No 24 0 0 24 Fuses
C-24V2-C20M Metered Metered CDU, 0U, 24 x IEC C13 Outlets, LED Amp Meter, 208V 20A Input w/ IEC 60320 C20 Inlet (Input power cord ordered separately), Paint: STI Black Vertical 208 1 20 4.16 C20 No 24 24 0 0 Fuses
C-24V2-L30M Metered Metered CDU, 0U, 24x IEC C13 Outlets, LED Amp Meter, 208V 30A Input w/ NEMA L6-30P Connector, 10ft (3m) Input Cord, Paint: STI Black Vertical 208 1 30 6.24 L6-30P No 24 24 0 0 Fuses
C-24VDD413-001 Metered Metered CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 208V 3-Phase Delta, 20A, NEMA L15-20P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 20 7.21 L15-20P No 24 24 0 0 Breakers
C-24VDE413-001 Metered Metered CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 208V 3-Phase Delta, 30A, NEMA L15-30P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 30 10.81 L15-30P No 24 24 0 0 Breakers
C-24VD-L30M Metered Metered CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meter, 208V 3-Phase Delta w/ L15-30P connector & cord, 10ft (3m), with retractable fuses Vertical 208 Delta 30 10.81 L15-30P No 24 24 0 0 Fuses
C-24VD-L30MA Metered Metered CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 208V 3-Phase Delta input w/ NEMA L15-30P connector & cord, 10ft (3m) Vertical 208 Delta 30 10.81 L15-30P No 24 18 6 0 Fuses
C-24VDV413A9 Metered Metered CDU, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED amp meters, 208V 3-Phase Delta, 50A, CS8365C Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C No 24 12 12 0 Breakers
C-24VDX413A9 Metered Metered CDU, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED amp meters, 208V 3-Phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 24 12 12 0 Breakers
C-24VE-C20M Metered Metered CDU, 0U, 24 x IEC C13 Outlets, LED Amp Meter, 230V, 16A Input, IEC 60320 C20 Inlet (Input power cord sold separately), Paint: STI Black Vertical 230 1 16 3.68 C20 No 24 24 0 0 Fuses
C-24VE-P32M Metered Metered CDU, 0U, 24 x IEC C13 Outlets, LED Amp Meter, 230V 32A Input w/ IEC 60309 Connector, 10ft (3m) Cord, Paint: STI Black Vertical 230 1 32 7.36 IEC 60309 No 24 24 0 0 Fuses
C-24VY-L30M Metered Metered CDU, 0U, 24 x IEC C13 Outlets,1 x NEMA 5-20R utility outlet, 3 x LED amp meter, 208V, 3-Phase Wye w/ L21-30P connector & cord, 10ft (3m), with retractable fuses Vertical 208 Wye 30 10.81 L21-30P No 24 24 0 0 Fuses
C-24VY-L30MA Metered Metered CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meter, 208V, 3-Phase Wye w/ L21-30P connector & cord, 10ft (3m) Vertical 208 Wye 30 10.81 L21-30P No 24 18 6 0 None
C-24VYY413A9 Metered Metered CDU, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED amp meters, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 24 12 12 0 Breakers
C-48V4J454 Metered Metered CDU, 0U, 48 x IEC C13 outlets, 3 x LED amp meters, 400V 3 Phase Wye 16A input w/ IEC 60309 6hr 5pin Plug, Top Cord Entry, 10ft (3m), Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 No 48 48 0 0 Breakers
C-48V4K454 Metered Metered CDU, 0U, 48 x IEC C13 outlets, 3 x LED amp meters, 400V 3 Phase Wye 32A input w/ IEC 60309 6hr 5pin Plug, Top Cord Entry, 10ft (3m), Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 No 48 48 0 0 Breakers
C-48V53454 Metered Metered CDU, 0U, 48 x IEC C13 outlets, 3 x LED amp meters, 415V 3 Phase Wye 20A input w/ IEC 60309 6hr 5pin Plug, Top Cord Entry, 10ft (3m), Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 No 48 48 0 0 Breakers
C-48V54454 Metered Metered CDU, 0U, 48 x IEC C13 outlets, 3 x LED amp meters, 415V 3 Phase Wye 30A input w/ IEC 60309 6hr 5pin Plug, Top Cord Entry, 10ft (3m), Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 No 48 48 0 0 Breakers
C-48V5Z454 Metered Metered CDU, 0U, 48 x IEC C13 outlets, 3 x LED amp meters, 415V 3 Phase Wye 30A input w/ NEMA L22-30P Plug, Top Cord Entry, 10ft (3m), Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P No 48 48 0 0 Breakers
C-4H2-C20 Metered Blade Server CDU, 1U, 4 x C19 Outlets, 208V, C20 Inlet, (Input Power Cord Sold Separately) Horizontal 208 1 20 4.16 C20 No 4 0 4 0 Fuses
C-4H2-L630 Metered Blade Server CDU, 1U, 4 x C19 Outlets, LED Amp Meter, 208V 30A w/ L6-30P input cord, 10ft (3m) Horizontal 208 1 30 6.24 L6-30P No 4 0 4 0 Fuses
C-4HD2A441A3 Metered Metered CDU, 2U, 4 each IEC 60320 C19 Outlets, LED amp meters, Dual 208V 20A input w/ IEC 60320 C20 Inlets (Power cords sold separately), Circuit Breakers Horizontal 208 1 20 4.16 C20 No 4 0 4 0 Breakers
C-4HD2C441A3 Metered Metered CDU, 2U, 4 each IEC 60320 C19 Outlets, LED amp meters, Dual 208V 30A input w/ NEMA L6-30P cordsets, 10ft (3m), Circuit Breakers Horizontal 208 1 30 6.24 C20 No 4 0 4 0 Breakers
C-4HDEA441A3 Metered Metered CDU, 2U, 4 each IEC 60320 C19 Outlets, LED amp meters, Dual 230V, 16A input w/ IEC C20 Inlet (power cords sold separately), Circuit Breakers Horizontal 230 1 16 3.68 C20 No 4 0 4 0 Breakers
C-4HDEK441A3 Metered Metered CDU, 2U, 4 each IEC 60320 C19 Outlets, LED amp meters, Dual 230V, 32A input w/ IEC 60309 6hr 3 pin cordsets, 10ft (3m), Circuit Breakers Horizontal 230 1 32 7.36 C20 No 4 0 4 0 Breakers
C-4HE-C20 Metered Blade Server CDU, 1U, 4 x C19 Outlets, LED Amp Meter, 230V, 16A w/ C20 Inlet Horizontal 230 1 20 4.60 C20 No 4 0 4 0 Fuses
C-4HE-P32 Metered Blade Server CDU, 1U, 4 x C19 Outlets, LED Amp Meter, 230V 32A w/ 60932 input cord, 10' (3 meters) Horizontal 230 1 20 4.60 IEC 60309 No 4 0 4 0 Fuses
CB-12H1-L530 Basic Basic CDU, 12 NEMA 5-20R outlets, 120V w/ L5-30P connector & cord, 10ft (3m) Horizontal 120 1 30 3.60 L5-30P No 12 0 0 12 Fuses
CB-12H2-C20 Basic Basic CDU, 12 IEC C13 outlets, 208-240V w/ C20 inlet (Input power cord ordered separately) Horizontal 208 1 20 4.16 C20 No 12 12 0 0 None
CB-12H2-L630 Basic Basic CDU, 12 IEC C13 outlets, 208-240V w/ L6-30P connector & cord, 10ft (3m) Horizontal 208 1 30 6.24 L6-30P No 12 12 0 0 Fuses
CB-24V1-C20 Basic Basic CDU, 24 NEMA 5-20R outlets, 120V w/ C20 inlet (Input power cord ordered separately) Vertical 120 1 20 2.40 C20 No 24 0 0 24 None
CB-24V1-L530 Basic Basic CDU, 24 NEMA 5-20R outlets, 120V w/ L5-30P connector & cord, 10ft (3m) Vertical 120 1 30 3.60 L5-30P No 24 0 0 24 Fuses
CB-24V2A401-001 Basic Basic CDU, 24 IEC C13 Outlets, 208V-240V, 20A, w/ C20 Inlet (Input power cord ordered separately), Bottom/Front Cord Entry, Doghouse Circuit Breakers Vertical 208 1 20 4.16 C20 No 24 24 0 0 Breakers
CB-24V2-C20 Basic Basic CDU, 24 IEC C13 outlets, 208-240V w/ C20 inlet (Input power cord ordered separately) Vertical 208 1 20 4.16 C20 No 24 24 0 0 None
CB-24V2C401-001 Basic Basic CDU, 24 IEC C13 Outlets, 208V-240V, 30A, NEMA L6-30P Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Doghouse Circuit Breakers Vertical 208 1 30 6.24 L6-30P No 24 24 0 0 Breakers
CB-24V2-L630 Basic Basic CDU, 24 IEC C13 outlets, 208-240V w/ L6-30P connector & cord, 10ft (3m) Vertical 208 1 30 6.24 L6-30P No 24 24 0 0 Fuses
CB-24VDD403-001 Basic Basic CDU, 24 IEC C13 Outlets, 208V 3-Phase Delta, 20A, NEMA L15-20P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 20 7.21 L15-20P No 24 24 0 0 Breakers
CB-24VDE403-001 Basic Basic CDU, 24 IEC C13 Outlets, 208V 3-Phase Delta, 30A, NEMA L15-30P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 30 10.81 L15-30P No 24 24 0 0 Breakers
CB-24VDV403A9 Basic Basic CDU, 12 x IEC C13 & 12 x C19 Outlets, 208V 3-Phase Delta, 50A, CS8365C Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 60 21.62 CS8365C No 24 12 12 0 Breakers
CB-24VDX403A9 Basic Basic CDU, 12 x IEC C13 & 12 x C19 Outlets, 208V 3-Phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 24 12 12 0 Breakers
CB-24VEA401-001 Basic Basic CDU, 24 IEC C13 Outlets, 230V, 16A, w/ C20 Inlet (Input power cord ordered separately), Bottom/Front Cord Entry, Doghouse Circuit Breakers Vertical 208 1 16 3.33 C20 No 24 24 0 0 Breakers
CB-24VEK401-001 Basic Basic CDU, 24 x IEC C13 Outlets, 230V, 32A, IEC 60309 6hr Ground (IP44) Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Circuit Breakers at the Base Vertical 230 1 32 7.36 IEC 60309 No 24 24 0 0 Breakers
CB-24VYL403-001 Basic Basic CDU, 24 IEC C13 Outlets, 208V 3-Phase Wye, 20A, NEMA L21-20P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Wye 20 7.21 L21-20P No 24 24 0 0 Breakers
CB-24VYM403-001 Basic Basic CDU, 24 IEC C13 Outlets, 208V 3-Phase Wye, 30A, NEMA L21-30P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Wye 30 10.81 L21-30P No 24 24 0 0 Breakers
CB-24VYY403A9 Basic Basic CDU, 12 x IEC C13 & 12 x C19 Outlets, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 24 12 12 0 Breakers
CS-12HD2C454A3 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 2U, 12 x IEC C19 Outlets, 2 x LED amp meters, (2) 208V 30A inputs w/ 2 x L6-30P connectors, 10ft (3m) cords , 2 x Temp/Humid Sensor Capable, Circuit Breakers Horizontal 208 1 30 12.48 2 x L6-30P Yes 12 0 12 0 Breakers
CS-12HD2G454A3 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 2U, 12 x IEC C19 Outlets, 2 x LED amp meters, (2) 208V 20A inputs w/ 2 x L6-20P connectors, 10ft (3m) cords , 2 x Temp/Humid Sensor Capable, Circuit Breakers Horizontal 208 1 20 8.30 2 x L6-20P Yes 12 0 12 0 Breakers
CS-12HDD444C8 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (6) IEC C13 and (6) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Delta, 20A, NEMA L15-20 Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breakers Horizontal 208 Delta 20 7.21 L15-20P Yes 12 6 6 0 Breakers
CS-12HDDD454A3 Smart Smart CDU with PIPS, 2U, 12 x IEC C19 Outlets, 3 LED Amp Meters Per Input Feed, 3-Phase 208V 20A Delta w/ 2 x NEMA L15-20P Connectors, 10ft (3m) Cords, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Horizontal 208 Delta 20 7.21 L15-20P Yes 12 0 12 0 Breakers
CS-12HDDE454A3 Smart Smart CDU with PIPS, 2U, 12 x IEC C19 Outlets, 3 LED Amp Meters Per Input Feed, 3-Phase 208V 30A Delta w/ 2 x NEMA L15-30P Connectors, 10ft (3m) Cords, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Horizontal 208 Delta 30 10.81 L15-30P Yes 12 0 12 0 Breakers
CS-12HDE444C8 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (6) IEC C13 and (6) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Delta, 30A, NEMA L15-30 Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breakers Horizontal 208 Delta 20 7.21 L15-20P Yes 12 6 6 0 Breakers
CS-12HDEJ454A3 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 2U, 12 x IEC C19 Outlets, 2 x LED amp meters, (2) 230V 16A inputs w/ IEC 2P+G Blue connectors, 10ft (3m) cords , 2 x Temp/Humid Sensor Capable, Circuit Breakers Horizontal 230 1 16 7.36 2 x IEC 60309 Yes 12 0 12 0 Breakers
CS-12HDEK454A3 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 2U, 12 x IEC C19 Outlets, 2 x LED amp meters, (2) 230V 32A inputs w/ IEC 2P+G Blue connectors, 10ft (3m) cords , 2 x Temp/Humid Sensor Capable, Circuit Breakers Horizontal 230 1 32 14.72 2 x IEC 60309 Yes 12 0 12 0 Breakers
CS-12HDV444A3 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (12) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Delta, 50A, CS8365C Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breaker Branch Circuit Protection Horizontal 208 Delta 50 18.01 CS8365C Yes 12 0 12 0 Breakers
CS-12HDX444A3 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (12) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breaker Branch Circuit Protection Horizontal 208 Delta 60 21.62 IEC 60309 Yes 12 0 12 0 Breakers
CS-12HDYL454A3 Smart Smart CDU with PIPS, 2U, 12 x IEC C19 Outlets, 3 LED Amp Meters Per Input Feed, 3-Phase 208V 20A Wye w/ 2 x NEMA L21-20P Connectors, 10ft (3m) Cords, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Horizontal 208 Wye 20 7.21 L21-20P Yes 12 0 12 0 Breakers
CS-12HDYM454A3 Smart Smart CDU with PIPS, 2U, 12 x IEC C19 Outlets, 3 LED Amp Meters Per Input Feed, 3-Phase 208V 30A Wye w/ 2 x NEMA L21-30P Connectors, 10ft (3m) Cords, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Horizontal 208 Wye 30 10.81 L21-30P Yes 12 0 12 0 Breakers
CS-12HYL444C8 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (6) IEC C13 and (6) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Wye, 20A, NEMA L21-20 Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breakers Horizontal 208 Wye 20 7.21 L21-20P Yes 12 6 6 0 Breakers
CS-12HYM444C8 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (6) IEC C13 and (6) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Wye, 30A, NEMA L21-30 Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breakers Horizontal 208 Wye 30 10.81 L21-30P Yes 12 6 6 0 Breakers
CS-12HYY444A3 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, (12) C19 Outlets, 3 LED Amp Meters, 208V, 3-phase Wye, 60 A, IEC 60309 9hr 5 Pin Blue Plug, 10 ft (3 m) Cord, 2 x Temperature/Humidity Sensors Capable, Circuit Breaker Branch Circuit Protection Horizontal 208 Wye 60 21.62 IEC 60309 Yes 12 0 12 0 Breakers
CS-12VD-P603 Smart Smart CDU, 0U, 12 x IEC C19 Outlets, 3 x LED amp meter, 208V 3-Phase Delta 60A input w/ IEC 60309 pin & sleeve plug, 6ft (1.8m) cord, (2) Temperature/Humidity Sensor Capable Vertical 208 Delta 60 21.62 IEC 60309 No 12 0 12 0 Fuses
CS-12VY-P603 Smart Smart CDU, 0U, 12 x IEC C19 Outlets, 3 x LED amp meter, 208V 3-Phase Wye 60A input w/ IEC 60309 pin & sleeve plug, 6ft (1.8m) cord, (2) Temperature/Humidity Sensor Capable Vertical 208 Wye 60 21.62 IEC 60309 No 12 0 12 0 Fuses
CS-15HDV454C3-013 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, 12xC19 and 3xC13 Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Delta 50A, 10 ft (3 m) Cord, CS8365C Plug, Circuit Breakers, 2 x Temp/Humid Capable Horizontal 208 Delta 50 18.01 CS8365C Yes 15 3 12 0 Breakers
CS-15HDX454C3-013 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, 12xC19 and 3xC13 Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Delta 60A, 10 ft (3 m) Cord, IEC 60309 9hr 4Pin Blue plug, Circuit Breakers, 2 x Temp/Humid Capable Horizontal 208 Delta 60 21.62 IEC 60309 Yes 15 3 12 0 Breakers
CS-15HYY454C3-013 Smart Smart CDU with PIPS (Per Input Power Sensing), 2U, 12xC19 and 3xC13 Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Wye 60A, 10 ft (3 m) Cord, IEC 60309 9hr 5Pin Blue plug, Circuit Breakers, 2 x Temp/Humid Capable Horizontal 208 Wye 60 21.62 IEC 60309 Yes 15 3 12 0 Breakers
CS-16V2-C20M Smart Smart CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 20 4.16 C20 No 16 16 0 0 Fuses
CS-16V2-L30M Smart Smart CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 30A w/ NEMA L6-30P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 30 6.24 L6-30P No 16 16 0 0 Fuses
CS-16VE-C20M Smart Smart CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 16A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 16 3.68 C20 No 16 16 0 0 Fuses
CS-16VE-P32M Smart Smart CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 32A input w/ IEC 60309 32A connector & cord, 10 ft (3m) w/ (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 32 7.36 IEC 60309 No 16 16 0 0 Fuses
CS-18V4J413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Bottom Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 No 18 0 18 0 Breakers
CS-18V4K413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Bottom Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 No 18 0 18 0 Breakers
CS-18V53413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Bottom Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 No 18 0 18 0 Breakers
CS-18V54413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Bottom Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 No 18 0 18 0 Breakers
CS-18V5Z413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A, NEMA L22-30P Plug, 10 ft (3 m) Cord, Bottom Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P No 18 0 18 0 Breakers
CS-18VDV413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Input Amp Meters, 208V 3-Phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Bottom/Base Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C No 18 0 18 0 Breakers
CS-18VDX413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Input Amp Meters, 208V 3-Phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Bottom/Base Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 18 0 18 0 Breakers
CS-18VYY411A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Input Amp Meters, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord, Bottom/Front Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 18 0 18 0 Breakers
CS-18VYY413A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Input Amp Meters, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord, Bottom/Base Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 18 0 18 0 Breakers
CS-24H5Z484A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 3U, (18) IEC C13 and (6) C19 Outlets, 3 LED Input Amp Meters, 240/415V 30A, 10 ft (3 m) Input Cord w/ NEMA L22-30P (Front Cord Entry), 20 A Circuit Breakers, 2 x Temp/Humid Capable Horizontal 415 Wye 30 21.60 L22-30P Yes 24 18 6 0 Breakers
CS-24V1-C20M Smart Smart CDU, 0U, 24 x NEMA 5-20R Outlets, (1) LED amp meter, 120V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 120 1 20 2.40 C20 No 24 0 0 24 Fuses
CS-24V1-L30M Smart Smart CDU, 0U, 24 x NEMA 5-20R Outlets, (1) LED amp meter, 120V 30A input w/ L5-30P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 120 1 30 3.60 L5-30P No 24 0 0 24 Fuses
CS-24V2A458C1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 208V 20A, C20 Inlet, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 20 4.16 C20 Yes 24 18 6 0 Breakers
CS-24V2-L20MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 208V 20A input w/ L6-20P connector and cord 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 20 4.16 L6-20P No 24 18 6 0 Fuses
CS-24V2-L30MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 208V 30A input w/ NEMA L6-30P connector and cord 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 30 6.24 L6-30P No 24 18 6 0 Fuses
CS-24V47458A3 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 0U, 24 x IEC C19 Outlets, 3 x LED Input Amp Meters, 230/400V 3-Phase Wye, 63A, IEC 60309 6hr 5 Pin Red Plug, 10ft (3m) Cord, Top Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 400 Wye 63 43.47 IEC 60309 No 24 0 24 0 Breakers
CS-24V4J425A9 Smart Smart PIPS CDU, Per Input Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 16A 230/400V 3-Phase, IEC 60309 6hr 5pin Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temperature /Humidity Capable Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 12 12 0 Breakers
CS-24V4K425A9 Smart Smart PIPS CDU, Per Input Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 32A 230/400V 3-Phase, IEC 60309 6hr 5pin Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temperature /Humidity Capable Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 12 12 0 Breakers
CS-24V4-P16M Smart Smart CDU, 0U, 24 x IEC C13 outlets, 3 x LED amp meters, 400V 3 Phase Wye 16A input w/ 60309 connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 400 Wye 16 11.04 IEC 60309 No 24 24 0 0 Fuses
CS-24V4-P16MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 400V 3-phase Wye input w/ IEC 60309 16A connector and cord 3m (10ft), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 400 Wye 16 11.04 IEC 60309 No 24 18 6 0 Fuses
CS-24V4-P32M Smart Smart CDU, 0U, 24 x IEC C13 outlets, 3 x LED amp meters, 400V 3 Phase Wye 32A input w/ 60309 connector & cord, 10' (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 400 Wye 32 22.08 IEC 60309 No 24 24 0 0 Fuses
CS-24V4-P32MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 400V input w/ IEC 60309 32A connector and cord 10', (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 400 Wye 32 22.08 IEC 60309 No 24 18 6 0 Fuses
CS-24V53425A9 Smart Smart PIPS CDU, Per Input Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 20A 240/415V 3-Phase, IEC 60309 6hr 5pin Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, Circuit Breakers, 2 x Temperature /Humidity Capable Vertical 415 Wye 20 14.40 IEC 60309 Yes 24 12 12 0 Breakers
CS-24V57458A3 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 0U, 24 x IEC C19 Outlets, 3 x LED Input Amp Meters, 240/415V 3-Phase Wye, 60A, IEC 60309 6hr 5 Pin Red Plug, 10ft (3m) Cord, Top Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 60 43.20 IEC 60309 No 24 0 24 0 Breakers
CS-24V5Z425A9 Smart Smart PIPS CDU, Per Input Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 30A 240/415V 3-Phase, NEMA L22-30P Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, Circuit Breakers, 2 x Temperature /Humidity Capable Vertical 415 Wye 30 21.60 L22-30P Yes 24 12 12 0 Breakers
CS-24VD-L30M Smart Smart CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 208V 3-Phase Delta input w/ NEMA L15-30P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 Delta 30 10.81 L15-30P No 24 24 0 0 Fuses
CS-24VD-L30MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 208V 3-phase 30A Delta input w/ L15-30P connector and cord 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 Delta 30 10.81 L15-30P No 24 18 6 0 Fuses
CS-24VDV454-006 Smart Smart CDU, 0U, 12 x IEC C19 & 12 x IEC C13 Outlets, 6 x LED Branch Current Meters, 208V 3-Phase Delta, 50A, CS8365C Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C No 24 12 12 0 Breakers
CS-24VDX454-006 Smart Smart CDU, 0U, 12 x IEC C19 & 12 x IEC C13 Outlets, 6 x LED Branch Current Meters, 208V 3-Phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 24 12 12 0 Breakers
CS-24VEA458C1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 230V 16A, C20 Inlet, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 16 3.68 C20 Yes 24 18 6 0 Breakers
CS-24VE-C20M Smart Smart CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 230V 16A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 16 3.68 C20 No 24 24 0 0 Fuses
CS-24VEK458C1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10ft (3m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 7.36 C20 Yes 24 18 6 0 Breakers
CS-24VE-P16MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 230V input w/ IEC 60309 16A connector and cord 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 16 3.68 IEC 60309 No 24 18 6 0 Fuses
CS-24VE-P32M Smart Smart CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 230V 32A input w/ IEC 60309 connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 32 7.36 IEC 60309 No 24 24 0 0 Fuses
CS-24VE-P32MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 230V input w/ IEC 60309 32A connector and cord 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 32 7.36 IEC 60309 No 24 18 6 0 Fuses
CS-24VY-L30M Smart Smart CDU, 0U, 24 x IEC C13 Outlets,1 x NEMA 5-20R utility outlet, 3 x LED amp meters, 208V 3-Phase Wye input w/ NEMA L21-30P connector & cord, 10ft (3m), bottom/front cord entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 Wye 30 10.81 L21-30P No 24 24 0 0 Fuses
CS-24VY-L30MA Smart Smart CDU, 0U, 18 x IEC C13 Outlets, 6 x IEC C19 Outlets, 3 x LED amp meters, 208V 3-phase 30A Wye input w/ L21-30P connector and cord 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 Wye 30 10.81 L21-30P No 24 18 6 0 Fuses
CS-24VYY454-006 Smart Smart CDU, 0U, 12 x IEC C19 & 12 x IEC C13 Outlets, 6 x LED Branch Current Meters, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 24 12 12 0 Breakers
CS-27VYL123-004 Smart Smart CDU, 0U, 21 x NEMA 5-20R (120V) & 6 x NEMA L6-20R (208V) Outlets, 3 LED Amp Meters, 208V 3-Phase Wye, 20A, NEMA L21-20P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, No BCP Vertical 208 Wye 20 7.21 L21-20P No 27 0 0 21 None
CS-27VY-L20M Smart Smart CDU, 0U, 21 x IEC C13 at 208V & 6 x NEMA 5-20R at 120V Outlets, 3 x LED Amp Meters, 208V 3-Phase Wye, 20A w/ NEMA L21-20P connector, 10 ft (3m) cord, front entry, (2) Temperature/Humidity Sensor Capable, w/ breaker branch circuit protection Vertical 208 Wye 20 7.21 L21-20P No 27 21 0 6 Fuses
CS-27VY-L20MX Smart Smart CDU, 0U, 21 x IEC C13 at 208V and 6 x NEMA 5-20R at 120V Outlets, 3 x LED Amp Meters, 208V 3-phase Wye, 20A, Bottom/Front Cord Entry, 3m (10) Cord with NEMA L21-20P, (2) Temperature/Humidity Sensor Capable, no branch circuit protection Vertical 208 Wye 20 7.21 L21-20P No 27 21 0 6 None
CS-27VY-L30M Smart Smart CDU, 0U, 21 x IEC C13 at 208V & 6 x NEMA 5-20R at 120V Outlets, 3 x LED Amp Meters, 208V 3-Phase Wye,30A w/ NEMA L21-30P connector and cord, 10', front entry, (2) Temperature/Humidity Sensor Capable, w/ breakers Vertical 208 Wye 30 10.81 L21-30P No 27 21 0 6 Fuses
CS-27VYL423-004 Smart Smart CDU, 0U, 21 x NEMA 5-20R (120V) & 6 x NEMA L6-20R (208V) Outlets, 3 LED Amp Meters, 208V 3-Phase Wye, 20A, NEMA L21-20P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 20 7.21 L21-20P No 27 0 0 21 Breakers
CS-27VYM423-004 Smart Smart CDU, 0U, 21 x NEMA 5-20R (120V) & 6 x NEMA L6-20R (208V) Outlets, 3 LED Amp Meters, 208V 3-Phase Wye, 30A, NEMA L21-30P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 30 10.81 L21-30P No 27 0 0 21 Breakers
CS-27VYM423-005 Smart Smart CDU, 0U, 21 x NEMA 5-20R (120V) & 6 x NEMA L6-30R (208V) Outlets, 3 LED Amp Meters, 208V 3-Phase Wye, 30A, NEMA L21-30P Plug, 10 ft (3 m) Cord, Bottom/Base Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 30 10.81 L21-30P No 27 0 0 21 Breakers
CS-2HD1A131Z1 Smart Smart Power Monitor, 1U, (2) IEC 60320 C20 Inlets (120V, 20A), (2) IEC 60320 C19 Outlets (120V, 20A), (2) Temperature/Humidity Sensor Capable (**Power cords sold separately) Horizontal 120 1 20 2.40 C20 No 2 0 2 0 None
CS-2HD2A131Z1 Smart Smart Power Monitor, 1U, (2) IEC 60320 C20 Inlets (208V, 20A), (2) IEC 60320 C19 Outlets (208V, 20A), (2) Temperature/Humidity Sensor Capable (**Power cords sold separately) Horizontal 208 1 20 4.16 C20 No 2 0 2 0 None
CS-2HD2C131Z1 Smart Smart Power Monitor, 1U, (2) NEMA L6-30P Input Cord Set, 10ft (3.0m), (2) NEMA L6-30R Output Cord Set, 3ft (0.91m), 208V, 30A, (2) Temperature/Humidity Sensor Capable Horizontal 208 1 30 6.24 L6-30P No 2 0 0 0 None
CS-2HD4J131Z1 Smart Smart Power Monitor, 1U, (2) IEC 60309 Input Cord Set, 10ft (3.0m), (2) IEC 60309 Output Cord Set, 3ft (0.91m), 230/400V 3-Phase Wye, 16A, (2) Temperature/Humidity Sensor Capable Horizontal 400 Wye 16 11.04 IEC 60309 No 2 0 0 0 None
CS-2HD4K131Z1 Smart Smart Power Monitor, 1U, (2) IEC 60309 Input Cord Set, 10ft (3.0m), (2) IEC 60309 Output Cord Set, 3ft (0.91m), 230/400V 3-Phase Wye, 32A, (2) Temperature/Humidity Sensor Capable Horizontal 400 Wye 32 22.08 IEC 60309 No 2 0 0 0 None
CS-2HD5Z131Z1 Smart Smart Power Monitor, 1U, (2) NEMA L22-30P Input Cord Set, 10ft (3.0m), (2) NEMA L22-30R Output Cord Set, 3ft (0.91m), 240/415V 3-Phase Wye, 30A, (2) Temperature/Humidity Sensor Capable Horizontal 400 Wye 32 22.08 IEC 60309 No 2 0 0 0 None
CS-2HDDD131Z1 Smart Smart Power Monitor, 1U, (2) NEMA L15-20P Input Cord Set, 10ft (3.0m), (2) NEMA L15-20R Output Cord Set, 3ft (0.91m) , 208V 3-Phase Delta, 20A, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 20 7.21 L15-20P No 2 0 0 0 None
CS-2HDDE131Z1 Smart Smart Power Monitor, 1U, (2) NEMA L15-30P Input Cord Set, 10ft (3.0m), (2) NEMA L15-30R Output Cord Set, 3ft (0.91m) , 208V 3-Phase Delta, 30A, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 30 10.81 L15-30P No 2 0 0 0 None
CS-2HDDV131Z1 Smart Smart Power Monitor, 1U, 2 x CS8365C Input Cords, 10 ft (3 m), 2 x CS8364C Output Cords, 36 in. (0.91 m), 208V 3-Phase Delta, 50A, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 50 18.01 2 x CS8364C No 2 0 0 0 None
CS-2HDDX131Z1 Smart Smart Power Monitor, 1U, 2 x IEC 60309 Splash-proof 9hr 4 Pin Blue Input Cords, 10 ft (3 m), 2 x IEC 60309 Splash-proof 9hr 4 Pin Blue Output Cords, 36 in. (0.91 m), 208V 3-Phase Delta, 60A, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 60 21.62 2 x IEC 60309 No 2 0 0 0 None
CS-2HDEA131Z1 Smart Smart Power Monitor, 1U, (2) IEC 60320 C20 Inlets (230V, 16A), (2) IEC 60320 C19 Outlets (230V, 16A), (2) Temperature/Humidity Sensor Capable (**Power cords sold separately) Horizontal 230 1 16 3.68 C20 No 2 0 2 0 None
CS-2HDEK131Z1 Smart Smart Power Monitor, 1U, (2) IEC 60309 Input Cord Set, 10ft (3.0m), (2) IEC 60309 Output Cord Set, 3ft (0.91m), 230V, 32A, (2) Temperature/Humidity Sensor Capable Horizontal 230 1 32 7.36 IEC 60309 No 2 0 0 0 None
CS-2HDYL131Z1 Smart Smart Power Monitor, 1U, (2) NEMA L21-20P Input Cord Set, 10ft (3.0m), (2) NEMA L21-20R Output Cord Set, 3ft (0.91m) , 208V 3-Phase Wye, 20A, (2) Temperature/Humidity Sensor Capable Horizontal 208 Wye 20 7.21 L21-20P No 2 0 0 0 None
CS-2HDYM131Z1 Smart Smart Power Monitor, 1U, (2) NEMA L21-30P Input Cord Set, 10ft (3.0m), (2) NEMA L21-30R Output Cord Set, 3ft (0.91m) , 208V 3-Phase Wye, 30A, (2) Temperature/Humidity Sensor Capable Horizontal 208 Wye 30 10.81 L21-30P No 2 0 0 0 None
CS-2HF2C222A3 Smart Smart Fail-Safe Transfer Switch, 1U, (2) IEC 60320 C19 Outlets (1xC19/Input), (2) LED Input Current Meters (1/input), 208-240V, 30A, (2) NEMA L6-30P Input Cord Set, 10ft (3.0m), (2) Temperature/Humidity Sensor Capable Horizontal 208 1 30 6.24 L6-30P No 2 0 2 0 None
CS-2HFEK222A3 Smart Smart Fail-Safe Transfer Switch, 1U, (2) IEC 60320 C19 Outlets (1xC19/Input), (2) LED Input Current Meters (1/input), (2) IEC 60309 Input Cord Set, 230V, 32A, 3.0m (10 ft), (2) Temperature/Humidity Sensor Capable Horizontal 230 1 32 7.36 IEC 60309 No 2 0 2 0 None
CS-36V4J454-A4C Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 230/400V 3-phase Wye, 16A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 Yes 36 24 12 0 Breakers
CS-36V4K411 Smart Smart CDU, 0U, 36 x IEC C13 outlets, 3 x LED Amp Meters, 230/400V 3-Phase Wye, 32A IEC 60309 (5-pin Pin/Sleeve, Red, 6 Oclock Ground) Connector, Bottom/Front Cord Entry, 3m (10) Cord, Circuit Breaker Protection, w/ (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 32 22.08 IEC 60309 No 36 36 0 0 Breakers
CS-36V4K454-A4C Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 230/400V 3-phase Wye, 32A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 Yes 36 24 12 0 Breakers
CS-36V53454-A4C Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 240/415V 3-phase Wye, 20A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 Yes 36 24 12 0 Breakers
CS-36V54454-A4C Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 240/415V 3-phase Wye, 30A, IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 36 24 12 0 Breakers
CS-36V5Z454-A4C Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 240/415V 3-phase Wye, 30A, NEMA L22-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P Yes 36 24 12 0 Breakers
CS-36VDD458A4 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Delta, 20A, NEMA L15-20P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 20 7.21 L15-20P Yes 36 24 12 0 Breakers
CS-36VDE411 Smart Smart CDU, 0U, 36 x IEC C13 outlets, 3 x LED Amp Meters, 208V 3-Phase Delta,30A w/ circuit breaker protection w/ NEMA L15-30P connector & cord, 10ft (3m), w/ (2) Temperature/Humidity Sensor Capable Vertical 208 Delta 30 10.81 L15-30P No 36 36 0 0 Breakers
CS-36VDE458A4 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Delta, 30A, NEMA L15-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 30 10.81 L15-30P Yes 36 24 12 0 Breakers
CS-36VYL458A4 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Wye, 20A, NEMA L21-20P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 20 7.21 L21-20P Yes 36 24 12 0 Breakers
CS-36VYM411 Smart Smart CDU, 0U, 36 x IEC C13 outlets, 3 x LED Amp Meters, 208V 3-Phase Wye,30A w/ circuit breaker protection w/ NEMA L21-30P connector & cord, 10ft (3m), w/ (2) Temperature/Humidity Sensor Capable Vertical 208 Wye 30 10.81 L21-30P No 36 36 0 0 Breakers
CS-36VYM458A4 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-phase Wye, 30A, NEMA L21-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 30 10.81 L21-30P Yes 36 24 12 0 Breakers
CS-3AVYL413 Smart Smart CDU, 0U, 12 x NEMA 5-20R at 120V, 9 x IEC C13 at 208V, 9 x IEC C19 at 208V, 208V 3-phase Wye 20A w/ circuit breaker protection, w/ L21-20P connector & cord, 10ft (3m) w/ (2) Temperature/Humidity Sensor Capable Vertical 208 Wye 20 7.21 L21-20P No 30 9 9 12 Breakers
CS-3AVYM413 Smart Smart CDU, 0U, 12 x NEMA 5-20R at 120V, 9 x IEC C13 at 208V, 9 x IEC C19 at 208V, 208V 3-phase Wye 30A Input w/ Circuit Breaker Protection, w/ NEMA L21-30P Connector, 10 ft (3m) Cord, 2 x Temperature & Humidity Capable Vertical 208 Wye 30 10.81 L21-30P No 30 9 9 12 Breakers
CS-42VDDE15 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 0U, 42 x IEC C13 Outlets, 3 x LED amp meters, 3 Phase Delta, 20A w/ NEMA L15-20P connector & cord, 10ft (3m), bottom/front cord entry, 2 x Temp/Humid Capable, Doghouse Circuit Breakers at bottom of unit. Vertical 208 Delta 20 7.21 L15-20P Yes 42 42 0 0 Breakers
CS-42VDEE15 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 0U, 42 x IEC C13 Outlets, 3 x LED amp meters, 3 Phase Delta, 30A w/ NEMA L15-30P connector & cord, 10ft (3m), bottom/front cord entry, 2 x Temp/Humid Capable, Doghouse Circuit Breakers at bottom of unit. Vertical 208 Delta 30 10.81 L15-30P Yes 42 42 0 0 Breakers
CS-42VDV411 Smart Smart CDU, 0U, 42 x IEC C13 Outlets, 3 x LED Current Meters, 208V 3-Phase Delta, 50A, CS8365C Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C No 42 42 0 0 Breakers
CS-42VDX411 Smart Smart CDU, 0U, 42 x IEC C13 Outlets, 3 x LED Current Meters, 208V 3-Phase Delta, 60A, IEC 60309 3P+PE 9Hr Connector, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 42 42 0 0 Breakers
CS-42VYLE15 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 0U, 42 x IEC C13 Outlets, 3 x LED amp meters, 3 Phase Wye, 20A w/ NEMA L21-20P connector & cord, 10ft (3m), bottom/front cord entry, 2 x Temp/Humid Capable, Doghouse Circuit Breakers at bottom of unit. Vertical 208 Wye 20 7.21 L21-20P Yes 42 42 0 0 Breakers
CS-42VYME15 Smart Smart CDU with PIPS (Per Inlet Power Sensing), 0U, 42 x IEC C13 Outlets, 3 x LED amp meters, 3 Phase Wye, 30A w/ NEMA L21-30P connector & cord, 10ft (3m), bottom/front cord entry, 2 x Temp/Humid Capable, Doghouse Circuit Breakers at bottom of unit. Vertical 208 Wye 30 10.81 L21-30P Yes 42 42 0 0 Breakers
CS-42VYY411 Smart Smart CDU, 0U, 42 x IEC C13 Outlets, 3 x LED Current Meters, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 42 42 0 0 Breakers
CS-48VD2-C20 Smart Smart CDU, 0U, 48 x IEC C13 Outlets, 2 x LED Meters, 208V 20A input w/ 2 x C20 Inlets, (2) Temperature/Humidity Sensor Capable Vertical 208 1 20 4.16 2 x C20 No 48 48 0 0 Fuses
CS-48VD2-L630 Smart Smart CDU, 0U, 48 x IEC C13 Outlets, 2 x LED Meters, 208V 30A input w/ 2 x L6-30P connector & cord, 10ft (3m) , (2) Temperature/Humidity Sensor Capable Vertical 208 1 30 6.24 2 x L6-30P No 48 48 0 0 Fuses
CS-48VDE-C20 Smart Smart CDU, 0U, 48 x IEC C13 Outlets, 2 x LED Meters, 230V 16A input w/ 2 x C20 Inlets, (2) Temperature/Humidity Sensor Capable Vertical 230 1 16 3.68 2 x C20 No 48 48 0 0 Fuses
CS-48VDE-P32 Smart Smart CDU, 0U, 48 x IEC C13 Outlets, 2 x LED Meters, 230V 32A input w/ 2 x 60309 32A connectors & cord, 10 ft (3m), (2) Temperature/Humidity Sensor Capable Vertical 230 1 32 7.36 2 x IEC 60309 No 48 48 0 0 Fuses
CS-48VDV458A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 36 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-Phase Delta, 50A, CS8365C Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 48 36 12 0 Breakers
CS-48VDX458A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 36 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-Phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 Yes 48 36 12 0 Breakers
CS-48VYY458A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 36 x IEC C13 & 12 x IEC C19 Outlets, 3 LED Amp Meters, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 Yes 48 36 12 0 Breakers
CS-4HDV452B6 Smart Smart CDU, 2U, 4 x NEMA L15-30R Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Delta 50A, 10 ft (3 m) Cord, CS8365C plug, 30 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 50 18.01 CS8365C No 4 0 0 0 Breakers
CS-4HDX452B6 Smart Smart CDU, 2U, 4 x NEMA L15-30R Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Delta 60A, 10 ft (3 m) Input Cord, IEC 60309 9hr 4 Pin Blue plug, 30A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 60 21.62 IEC 60309 No 4 0 0 0 Breakers
CS-4HYY452B6 Smart Smart CDU, 2U, 4 x NEMA L15-30R Receptacles, 3 LED Input Amp Meters, 208V 3-Phase Wye 60A, 10 ft (3 m) Cord, IEC 60309 9hr 5 Pin Blue plug, 30 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 Wye 60 21.62 IEC 60309 No 4 0 0 0 Breakers
CS-6HDV452B4 Smart Smart CDU, 2U, 6 x NEMA L6-30R Outlets, 3 LED Input Amp Meters, 208V 3-Phase Delta 50A, 10 ft (3 m) Cord, CS8365C plug, 30 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 50 18.01 CS8365C No 6 0 0 0 Breakers
CS-6HDX452B4 Smart Smart CDU, 2U, 6 x NEMA L6-30R Outlets, 3 LED Input Amp Meters, 208V 3-Phase Delta 60A, 10 ft (3 m) Cord, IEC 60309 9hr 4 Pin Blue plug, 30 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 Delta 60 21.62 IEC 60309 No 6 0 0 0 Breakers
CS-6HYY452B4 Smart Smart CDU, 2U, 6 x NEMA L6-30R Outlets, 3 LED Input Amp Meters, 208V 3-Phase Wye 60A, 10 ft (3m) Cord, IEC60309 9hr 5 Pin Blue Plug, 30 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 Wye 60 21.62 IEC 60309 No 6 0 0 0 Breakers
CS-84VD2-L620 Smart Smart CDU, 0U, 84 x IEC C13 Outlets, 6 x LED amp meters, Dual 208V 20A Inputs w/ 2 x NEMA L6-20P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable Vertical 208 1 20 4.16 2 x L6-20P No 84 84 0 0 Fuses
CS-84VD2-L630 Smart Smart CDU, 0U, 84 x IEC C13 Outlets, 6 x LED amp meters, Dual 208V 30A Inputs w/ 2 x NEMA L6-30P connector & cord, 10 ft (3 m), (2) Temperature/Humidity Sensor Capable Vertical 208 1 30 6.24 2 x L6-30P No 84 84 0 0 Fuses
CSG-24V2A415A1 Smart POPS Smart POPS/PIPS CDU, Per Outlet and Per Input Power Sensing, 0U, 18 x IEC C13 and 6 x C19, 1 x LED Amp Meter at the Top, 208V, 20A w/ C20 Inlet (Input power cord ordered separately), Bottom/Front Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 20 4.16 C20 Yes 24 18 6 0 Breakers
CSG-24V2C415A1 Smart POPS Smart POPS/PIPS CDU, Per Outlet and Per Input Power Sensing, 0U, 18 x IEC C13 and 6 x C19, 1 x LED Amp Meter at the Top, 208V, 30A w/ NEMA L6-30P Plug, 10ft (3m) Cord, Bottom/Front Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 24 18 6 0 Breakers
CSG-24V4J421A9 Smart POPS Smart POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 230/400V 3-Phase Wye, 16A, IEC 60309 6hr 5pin Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 400 1 16 6.40 IEC 60309 Yes 24 12 12 0 Breakers
CSG-24V4K425A9 Smart POPS Smart POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters Located in the Middle of the Unit, 230/400V 3-Phase, 32A IEC 60309 (4P+N+PE) 6hr Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humidity Sensor Capable Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 12 12 0 Breakers
CSG-24V53421A9 Smart POPS Smart POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 240/415V 3-Phase Wye, 20A, IEC 60309 6hr 5pin Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 1 20 8.30 IEC 60309 Yes 24 12 12 0 Breakers
CSG-24V54421A9 Smart POPS Smart POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 240/415V 3-Phase Wye, 30A, IEC 60309 6hr 5pin Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 12 12 0 Breakers
CSG-24V5Z421A9 Smart POPS Smart POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meter, Middle Display, 240/415V 3-Phase Wye, 30A, NEMA L22-30P Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P Yes 24 12 12 0 Breakers
CSG-24VDV415A9 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19, 3 x LED Amp Meters, 3-Phase Delta, 50A w/ CS8365C Connector and Cord, 10ft (3m), Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 24 12 12 0 Breakers
CSG-24VDX415A9 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19, 3 x LED Amp Meters, 3-Phase Delta, 60A w/ IEC 60309 3P+PE 9Hr Connector and Cord, 10ft (3m), Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 Yes 24 12 12 0 Breakers
CSG-24VEA415A1 Smart POPS Smart POPS/PIPS CDU, Per Outlet and Per Input Power Sensing, 0U, 18 x IEC C13 and 6 x C19, 1 x LED Amp Meter at the Top, 230V, 16A w/ C20 Inlet (Input power cord ordered separately), Bottom/Front Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 16 3.68 C20 Yes 24 18 6 0 Breakers
CSG-24VEK415A1 Smart POPS Smart POPS/PIPS CDU, Per Outlet and Per Input Power Sensing, 0U, 18 x IEC C13 and 6 x C19, 1 x LED Amp Meter at the Top, 230V, 32A w/ IEC 60309 Connector and Cord, 10ft (3m), Bottom/Front Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 24 18 6 0 Breakers
CSG-24VYY411A9 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19, 3 x LED Amp Meters, 3-Phase Wye, 60A w/ IEC 60309 4P+PE 9Hr Connector and Cord, 10ft (3m), Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 Yes 24 12 12 0 Breakers
CW-16HD1A454 Switched Switched CDU with PIPS (Per Input Power Sensing), 2U, 16 x NEMA 5-20R Outlets, 2x Amp Meters, Dual 120V 20A IEC C20 Inlets, Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 120 1 20 2.40 C20 Yes 16 0 0 16 Breakers
CW-16HD1B454 Switched Switched CDU with PIPS (Per Input Power Sensing), 2U, 16 x NEMA 5-20R Outlets, 2x Amp Meters, Dual 120V 30A NEMA L5-30P Plugs, 10 ft (3M) Cords, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 120 1 30 3.60 L5-30P Yes 16 0 0 16 Breakers
CW-16HD2A454 Switched Switched CDU with PIPS (Per Input Power Sensing), 2U, 16 x IEC C13 Outlets, 2x Amp Meters, Dual 208V 20A w/ IEC C20 Inlets (Front Cord Entry), Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 208 1 20 4.16 C20 Yes 16 16 0 0 Breakers
CW-16HD2C454 Switched Switched CDU with PIPS (Per Input Power Sensing), 2U, 16 x IEC C13 Outlets, 2x Amp Meters, Dual 208V 30A w/ NEMA L6-30P Plugs, (Front Cord Entry), 10 ft (3m) cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 1 30 6.24 L6-30P Yes 16 16 0 0 Breakers
CW-16HDEA454 Switched Switched CDU with PIPS (Per Input Power Sensing), 2U, 16 x IEC C13 Outlets, 2x Amp Meters, Dual 230V 16A w/ IEC C20 Inlets (Front Cord Entry), Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 230 1 16 3.68 C20 Yes 16 16 0 0 Breakers
CW-16HDEK454 Switched Switched CDU with PIPS (Per Input Power Sensing), 2U, 16 x IEC C13 Outlets, 2x Amp Meters, Dual 230V 32A w/ IEC 60309 2P+PE 6Hr Blue Plugs, (Front Cord Entry), 10 ft (3m) cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 230 1 32 7.36 IEC 60309 Yes 16 16 0 0 Breakers
CW-16HF1A452 Switched Switched Fail-safe Transfer Switch CDU, 2U, (16) NEMA 5-20R Outlets, (2) Input Current Meters, 120V 20A w/ IEC C20 Inlet (Front Cord Entry), (2) Temperature/Humidity Sensor Capable, 20 A Circuit Breakers (Input power cord sold separately) Horizontal 120 1 20 2.40 C20 Yes 16 0 0 16 Breakers
CW-16HF1B452 Switched Switched Fail-safe Transfer Switch CDU, 2U, (16) NEMA 5-20R Outlets, (2) Input Current Meters, 120V 30A, NEMA L5-30P Connector (Front Cord Entry), 10 ft (3 m) Cord Set, (2) Temperature/Humidity Sensor Capable, 20A Circuit Breakers Horizontal 120 1 30 3.60 L5-30P Yes 16 0 0 16 Breakers
CW-16HF2A452 Switched Switched Fail-safe Transfer Switch CDU, 2U, (16) IEC C13 Outlets, (2) Input Current Meters, (2) 200-240 V 20A w/ IEC C20 Inlet (Front Cord Entry), (2) Temperature/Humidity Sensor Capable, 20 A Circuit Breakers (Input power cords sold separately) Horizontal 208 1 20 4.16 C20 Yes 16 16 0 0 Breakers
CW-16HF2C452 Switched Switched Fail-safe Transfer Switch CDU, 2U, (16) IEC C13 Outlets, (2) Input Current Meters, (2) 200-240 V 30A w/ NEMA L6-30P, 10 ft (3 m) Power Cords, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Horizontal 208 1 30 6.24 L6-30P Yes 16 16 0 0 Breakers
CW-16HFEA452 Switched Switched Fail-safe Transfer Switch CDU, 2U, (16) IEC C13 Outlets, (2) Input Current Meters, (2) 230 V 16A w/ IEC C20 Inlet (Front Cord Entry), (2) Temperature/Humidity Sensor Capable, 20 A Circuit Breakers (Input power cords sold separately) Horizontal 230 1 16 3.68 C20 Yes 16 16 0 0 Breakers
CW-16HFEK452 Switched Switched Fail-safe Transfer Switch CDU, 2U, (16) IEC C13 Outlets, (2) Input Current Meters, (2) 230 V 32A w/ IEC 60309 2P+G 32A, 3 m (10 ft) Power Cords, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Horizontal 230 1 32 7.36 IEC 60309 Yes 16 16 0 0 Breakers
CW-16V1A317 Switched Switched CDU with PIPS, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses (Input power cord sold separately) Vertical 120 1 20 2.40 C20 Yes 16 0 0 16 Fuses
CW-16V1B317 Switched Switched CDU with PIPS, 0U, 16 x NEMA 5-20R Outlets, LED amp meter, 120V 30A input w/ L5-30P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 120 1 30 3.60 L5-30P Yes 16 0 0 16 Fuses
CW-16V2A317 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 20A input w/ C20 Inlet (Input power cord ordered separately), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 20 4.16 C20 Yes 16 16 0 0 Fuses
CW-16V2-C20MX Switched Switched CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, no branch circuit protection (Input power cord ordered separately) Vertical 208 1 20 4.16 C20 No 16 16 0 0 None
CW-16V2C317 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 208V 30A input w/ L6-30P connector & cord, 10ft (3m), Bottom/Bottom Cord Entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 30 6.24 L6-30P Yes 16 16 0 0 Fuses
CW-16VEA317 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meters, 230V 16A input w/ C20 Inlet (Input power cord ordered separately), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 16 3.68 C20 Yes 16 16 0 0 Fuses
CW-16VE-C20MX Switched Switched CDU, 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 16A input w/ C20 inlet, (2) Temperature/Humidity Sensor Capable, no branch circuit protection Vertical 230 1 16 3.68 C20 No 16 16 0 0 Fuses
CW-16VEK317 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 16 x IEC C13 Outlets, LED amp meter, 230V 32A input w/ IEC 60309 connector & cord, 10ft (3m), Bottom/Bottom Entry, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 32 7.36 IEC 60309 Yes 16 16 0 0 Fuses
CW-24V2A311A1 Switched Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 20A input w/ C20 Inlet, Bottom/Front Cord Entry, (2) Temperature/Humidity Sensor Capable, Retractable Fuses Vertical 208 1 20 4.16 C20 No 24 18 6 0 Fuses
CW-24V2A415 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, (1) Input LED Amp Meter, 208V 20A Input w/ IEC 60320 C20 Inlet, Bottom/Front Cord Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 20 4.16 C20 Yes 24 24 0 0 Breakers
CW-24V2A458C1 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (1) Input LED Amp Meter in the middle of the unit, 208V 20A w/ C20 Inlet, Top/top Cord Entry, (2) Temp/Humidity Capable, Circuit Breakers ** Power cord purchased separately ** Vertical 208 1 20 4.16 C20 Yes 24 18 6 0 Breakers
CW-24V2-C20 Switched Switched CDU, 24 x IEC C13 Outlets, 208v 20a, 3 x LED Meter, C20 Inlet, 2 x Temp/Humid Capable Vertical 208 1 20 4.16 C20 No 24 24 0 0 Fuses
CW-24V2-C20M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 208V 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 20 4.16 C20 No 24 24 0 0 Fuses
CW-24V2C311A1 Switched Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 30A input w/ L6-30P connector and cord, Bottom/Front Cord Entry, 3m (10') Cord, (2) Temperature/Humidity Sensor Capable, Retractable Fuses Vertical 208 1 30 6.24 L6-30P No 24 18 6 0 Fuses
CW-24V2C415 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, (1) Input LED Amp Meter, 208V 30A Input w/ NEMA L6-30P Plug, Bottom/Front Cord Entry, 3m (10') Cord, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 6.24 NEMA L6-30P Yes 24 24 0 0 Breakers
CW-24V2C458C1 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (1) Input LED Amp Meter in the middle of the unit, 208V 30A Input w/ NEMA L6-30P Plug, Top/top Cord Entry, 3m (10') Cord, (2) Temp/Humidity Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 24 18 6 0 Breakers
CW-24V2-L20M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 208V 20A input w/ L6-20P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 20 4.16 L6-20P No 24 24 0 0 Fuses
CW-24V2-L30M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 208V 30A input w/ L6-30P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 208 1 30 6.24 L6-30P No 24 24 0 0 Fuses
CW-24V4J415 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 16A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 24 0 0 Breakers
CW-24V4J415A1 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 16A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 18 6 0 Breakers
CW-24V4J425A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 16A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V4K415 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 32A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 24 0 0 Breakers
CW-24V4K415A1 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 32A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 18 6 0 Breakers
CW-24V4K425A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 32A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V53415 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 20A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Vertical 415 Wye 20 14.40 IEC 60309 Yes 24 24 0 0 Breakers
CW-24V53415A1 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 20A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 20 14.40 IEC 60309 Yes 24 18 6 0 Breakers
CW-24V53425A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 20A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 20 14.40 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V54415 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 24 0 0 Breakers
CW-24V54415A1 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A IEC 60309 6Hr, 5-pin, Red Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 18 6 0 Breakers
CW-24V54425A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V5Z415 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A NEMA L22-30P Plug, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, 2 x Temp/Humid Capable Vertical 415 Wye 30 21.60 L22-30P Yes 24 24 0 0 Breakers
CW-24V5Z415A1 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A NEMA L22-30P Plug, Bottom/Front Cord Entry, 10ft (3m) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 18 6 0 Breakers
CW-24V5Z425A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A NEMA L22-30P Connector, Middle Display and Network Access, Bottom/Front Cord Entry, 3m (10ft) Cord, Circuit Breakers, (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 30 21.60 L22-30P Yes 24 12 12 0 Breakers
CW-24VDD311A1 Switched Switched CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10ft (3m) Cord Set, Bottom/front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Delta 20 7.21 L15-20P No 24 18 6 0 Fuses
CW-24VDE311A1 Switched Switched CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 3-phase Delta, 30A w/ NEMA L15-30P Cord Set, 10ft (3m), Bottom/front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Delta 30 10.81 L15-30P No 24 18 6 0 Fuses
CW-24VD-L20M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Delta 20A Input w/ NEMA L15-20P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Vertical 208 Delta 20 7.21 L15-20P No 24 24 0 0 Fuses
CW-24VD-L30M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 3-phase Delta 30A Input w/ NEMA L15-30P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Vertical 208 Delta 30 10.81 L15-30P No 24 24 0 0 Fuses
CW-24VDV425A9 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 24 12 12 0 Breakers
CW-24VDV454 Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C No 24 24 0 0 Breakers
CW-24VDX425A9 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 Yes 24 12 12 0 Breakers
CW-24VDX454 Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 24 24 0 0 Breakers
CW-24VDX454A1 Switched Switched CDU, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 60A w/ IEC 60309 9hr 4Pin Blue Plug, 10ft (3m), Top Power Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 24 18 6 0 Breakers
CW-24VEA311A1 Switched Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230V 16A Input w/ IEC C20 Inlet, Bottom/Front Cord Entry, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Vertical 230 1 16 3.68 C20 No 24 18 6 0 Fuses
CW-24VEA415 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 1 LED Amp Meter, 230V 16A Input w/ IEC 60320 C20 Inlet, Bottom/Front Cord Entry, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 16 3.68 L6-30P Yes 24 24 0 0 Breakers
CW-24VEA458C1 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (1) Input LED Amp Meter in the middle of the unit, 230V 16A w/ C20 Inlet, Top/top Cord Entry, (2) Temp/Humidity Capable, Circuit Breakers ** Power cord purchased separately ** Vertical 230 1 16 3.68 C20 Yes 24 18 6 0 Breakers
CW-24VE-C20 Switched Switched CDU, 24 x IEC C13 Outlets, 230v 20a, 3 x LED Meter, C20 Inlet, 2 x Temp/Humid Capable Vertical 230 1 20 4.60 C20 No 24 24 0 0 Fuses
CW-24VE-C20M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED amp meters, 230V 16A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 16 3.68 C20 No 24 24 0 0 Fuses
CW-24VEK311A1 Switched Switched CDU, 0U, 18 x IEC C13 Outlets and 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230V 32A Input w/ IEC 60309 Connector, Bottom/Front Cord Entry, 3m (10) Cord, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Vertical 230 1 32 7.36 IEC 60309 No 24 18 6 0 Fuses
CW-24VEK415 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, 1 LED Amp Meter, 230V 32A, IEC 60309 6hr Ground (IP44) Plug, Bottom/Front Cord Entry, 3 m (10 ft), 2 x Temp/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 7.36 C20 Yes 24 24 0 0 Breakers
CW-24VEK458C1 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, (1) Input LED Amp Meter in the middle of the unit, 230V 32A Input w/ IEC 60309 6hr 3 Pin Blue Plug, Top/top Cord Entry, 3m (10') Cord, (2) Temp/Humidity Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 24 18 6 0 Breakers
CW-24VE-P32M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3x LED amp meter, 230V 32A input w/ IEC 60309 connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, with retractable fuses Vertical 230 1 32 7.36 IEC 60309 No 24 24 0 0 Fuses
CW-24VY-L20M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, (1) NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 20A Input w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Vertical 208 Wye 20 7.21 L21-20P No 24 24 0 0 Fuses
CW-24VY-L30M Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters, 3-phase Wye 30A Input w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, (2) Temperature/Humidity Sensor Capable, with Retractable Fuses Vertical 208 Wye 30 10.81 L21-30P No 24 24 0 0 Fuses
CW-24VYL311A1 Switched Switched CDU, 0U, 18 x IEC C13, 6 x IEC C19, 1 x NEMA 5-20R Utility Outlets, 3 x LED Amp Meters, 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, Bottom/front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Wye 20 7.21 L21-20P No 24 18 6 0 Fuses
CW-24VYM311A1 Switched Switched CDU, 0U, 18 x IEC C13 & 6 x IEC C19, 1 x NEMA 5-20R Utility Outlets, 3 x LED Amp Meters, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Bottom/front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Wye 30 10.81 L21-30P No 24 18 6 0 Fuses
CW-24VYM354A1 Switched Switched CDU, 0U, 18 x IEC C13, 6 x IEC C19 Outlets, 1 x NEMA 5-20R Utility Outlet, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Wye 30 10.81 L21-30P No 24 18 6 0 Fuses
CW-24VYY425A9 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 Yes 24 12 12 0 Breakers
CW-24VYY454 Switched Switched CDU, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 24 24 0 0 Breakers
CW-24VYY454A1 Switched Switched CDU, 0U, 18 x IEC C13 and 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 60A w/ IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord Set, Top Power Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 24 18 6 0 Breakers
CW-2H1-C20 Switched Switched CDU, Intelligent IPM, 2 x NEMA 5-20R Controllable Outlets, 120V w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable (Input power cord ordered separately) Horizontal 120 1 20 2.40 C20 No 2 0 0 2 None
CW-2H2-C20 Switched Switched CDU, Intelligent IPM, 2 x IEC C13 Controllable Outlets, 208V w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable (Input power cord ordered separately) Horizontal 208 1 20 4.16 C20 No 2 2 0 0 None
CW-30VDD458C2 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10ft (3m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P No 30 24 6 0 Breakers
CW-30VDE458C2 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 30A w/ NEMA L15-30P Connector, 10ft (3m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P No 30 24 6 0 Breakers
CW-30VYL458C2-012 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P No 30 24 6 0 Breakers
CW-30VYM458C2-012 Switched Switched CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Wye 30 10.81 L21-30P No 30 24 6 0 Breakers
CW-48V4J458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A w/ IEC 60309 6hr Plug, 10 ft (3 m) Cord, Top Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 Yes 48 36 12 0 Breakers
CW-48V4K458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A w/ IEC 60309 6hr Plug, 10 ft (3 m) Cord, Top Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 Yes 48 36 12 0 Breakers
CW-48V53458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 & 12xC19), 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A w/ IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Top Cord Entry, 2 x Temp/Humdity Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 Yes 48 36 12 0 Breakers
CW-48V54458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 & 12xC19), 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ IEC 60309 6hr 5 Pin Red Plug, 10 ft (3 m) Cord, Top Cord Entry, 2 x Temp/Humdity Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 48 36 12 0 Breakers
CW-48V5Z454-A1P Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ NEMA L22-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P Yes 48 36 12 0 Breakers
CW-48VDD325A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters in the Middle of the Unit, 208V 3-phase Delta, 20A, NEMA L15-20P with 10 ft (3 m) Cord, Bottom/front Cord Entry, 2 x Temp/Humidity Sensor Capable, Fuse Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P Yes 48 36 12 0 Fuses
CW-48VDE325A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters in the Middle of the Unit, 208V 3-phase Delta, 30A, NEMA L15-30P with 10 ft (3 m) Cord, Bottom/front Cord Entry, 2 x Temp/Humidity Sensor Capable, Fuse Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P Yes 48 36 12 0 Fuses
CW-48VDV411 Switched Switched CDU, 0U, 48 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A w/ CS8365C Connector, 10 ft (3 m) Cord, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, 20A Breaker Branch Circuit Protection Vertical 208 Delta 50 18.01 CS8365C No 48 48 0 0 Breakers
CW-48VDX411 Switched Switched CDU, 0U, 48 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Front Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, 20A Breaker Branch Circuit Protection Vertical 208 Delta 60 21.62 IEC 60309 No 48 48 0 0 Breakers
CW-48VYL325A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters in the Middle of the Unit, 208V 3-phase Wye, 20A, NEMA L21-20P with 10 ft (3 m) Cord, Bottom/front Cord Entry, 2 x Temp/Humidity Sensor Capable, Fuse Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P Yes 48 36 12 0 Fuses
CW-48VYM325A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters in the Middle of the Unit, 208V 3-phase Wye, 30A, NEMA L21-30P with 10 ft (3 m) Cord, Bottom/front Cord Entry, 2 x Temp/Humidity Sensor Capable, Fuse Branch Circuit Protection Vertical 208 Wye 30 10.81 L21-30P Yes 48 36 12 0 Fuses
CW-48VYY411 Switched Switched CDU, 0U, 48 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Wye, 60A, IEC 60309 9Hr 5 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Front Entry, Top Display/Network, (2) Temperature/Humidity Sensor Capable, 20A Breaker Branch Circuit Protection Vertical 208 Wye 60 21.62 IEC 60309 No 48 48 0 0 Breakers
CW-8H2A211 Switched Switched, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 208V 20A w/ IEC 60320 C20 Inlet, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection (Input power cord ordered separately) Horizontal 208 1 20 4.16 C20 No 8 8 0 0 Fuses
CW-8H2C211 Switched Switched, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3m (10ft) Cord, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection Horizontal 208 1 30 6.24 L6-30P No 8 8 0 0 Fuses
CW-8HEA211 Switched Switched CDU, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 16A w/ IEC 60320 C20 Inlet, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection (Input power cord ordered separately) Horizontal 230 1 16 3.68 C20 No 8 8 0 0 Fuses
CW-8HEK211 Switched Switched CDU, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection Horizontal 230 1 32 7.36 IEC 60309 No 8 8 0 0 Fuses
CWG-16H2A454 Switched POPS Switched PIPS/POPS CDU, Per Outlet Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V 20A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 208 1 20 4.16 C20 Yes 16 16 0 0 Breakers
CWG-16H2C454 Switched POPS Switched PIPS/POPS CDU, Per Outlet Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 1 30 6.24 L6-30P Yes 16 16 0 0 Breakers
CWG-16HEA454 Switched POPS Switched PIPS/POPS CDU, Per Outlet Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 16A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately). Horizontal 230 1 16 3.68 C20 Yes 16 16 0 0 Breakers
CWG-16HEK454 Switched POPS Switched PIPS/POPS CDU, Per Outlet Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 230 1 32 7.36 IEC 60309 Yes 16 16 0 0 Breakers
CWG-16V2A313A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 208V 20A w/ IEC C20 Inlet (Bottom Entry), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses (Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 No 16 12 4 0 Fuses
CWG-16V2C313A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 208V 30A w/ NEMA L6-30P Connector and Cord (Bottom Cord Entry), 3m (10ft), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 1 30 6.24 L6-30P No 16 12 4 0 Fuses
CWG-16VEA313A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 230V 16A w/ IEC C20 inlet (Bottom Entry), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses (Power Cord Sold Separately) Vertical 230 1 16 3.68 C20 No 16 12 4 0 Fuses
CWG-16VEK313A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 230V 32A w/ IEC 60309 Connector and Cord (Bottom Cord Entry), 3m (10ft), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 230 1 32 7.36 IEC 60309 No 16 12 4 0 Fuses
CWG-24V2A415C1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, LED Amp Meter, 208V 20A w/ IEC C20 Inlet, Bottom/Front Entry, 2 x Temp/Humid Capable, Circuit Breakers (power cord sold separately). Vertical 208 1 20 4.16 C20 Yes 24 18 6 0 Breakers
CWG-24V2C415C1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, LED Amp Meter, 208V 30A w/ NEMA L6-30P Connector and Cord, Bottom/Front Entry, 3m (10ft) Cord, 2 x Temp/Humid Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 24 18 6 0 Breakers
CWG-24V4J458A1 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye 16A, IEC 60309 (4P+N+PE) 6hr Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 18 6 0 Breakers
CWG-24V4J458A9 Switched POPS Switched POPS and PIPS (Per Input Power Sensing and Per Outlet Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye 16A, IEC 60309 (5-pin Pin/Sleeve, Red, 6 O'clock Ground) Plug, 3m (10ft) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Sensor Capable, Circuit Breakers Branch Circuit Protection Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24V4K458A1 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye 32A, IEC 60309 (4P+N+PE) 6hr Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 18 6 0 Breakers
CWG-24V4K458A9 Switched POPS Switched POPS and PIPS (Per Input Power Sensing and Per Outlet Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye 32A, IEC 60309 (5-pin Pin/Sleeve, Red, 6 O'clock Ground) Plug, 3m (10ft) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Sensor Capable, Circuit Breakers Branch Circuit Protection Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24V53458A1 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 20A, IEC 60309 (4P+N+PE) 6hr Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 Yes 24 18 6 0 Breakers
CWG-24V53458A9 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 20A, IEC 60309 6hr 5 Pin Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24V54458A1 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 30A, IEC 60309 (4P+N+PE) 6hr Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 18 6 0 Breakers
CWG-24V54458A9 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 30A, IEC 60309 6hr 5 Pin Red Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24V5Z458A1 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 30A, NEMA L22-30P Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P Yes 24 18 6 0 Breakers
CWG-24V5Z458A9 Switched POPS Switched POPS CDU, PIPS (Per Input Power Sensing), 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye 30A, NEMA L22-30P Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24VDD311A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Delta, 20A w/ NEMA L15-20P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Delta 20 7.21 L15-20P No 24 18 6 0 Fuses
CWG-24VDE311A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Delta, 30A w/ NEMA L15-30P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Delta 30 10.81 L15-30P No 24 18 6 0 Fuses
CWG-24VDV425A9 Switched POPS Switched POPS CDU, PIPS - Per Inlet Power Sensing, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Bottom/Front Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 24 12 12 0 Breakers
CWG-24VDV454A1 Switched POPS Switched POPS CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C No 24 18 6 0 Breakers
CWG-24VDX425A9 Switched POPS Switched POPS CDU, PIPS - Per Inlet Power Sensing, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Bottom/Front Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24VDX454A1 Switched POPS Switched POPS CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 No 24 18 6 0 Breakers
CWG-24VEA415C1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, LED Amp Meter, 230V 16A w/ IEC C20 Inlet, Bottom/Front Entry, 2 x Temp/Humid Capable, Circuit Breakers (power cord sold separately). Vertical 230 1 16 3.68 C20 Yes 24 18 6 0 Breakers
CWG-24VEK415C1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, LED Amp Meter, 230V 32A w/ IEC 60309 2P+PE 6Hr Blue Plug, Bottom/Front Entry, 3m (10ft) Cord, 2 x Temp/Humid Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 24 18 6 0 Breakers
CWG-24VYL311A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Wye, 20A w/ NEMA L21-20P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Wye 20 7.21 L21-20P No 24 18 6 0 Fuses
CWG-24VYM311A1 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Wye, 30A w/ NEMA L21-30P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 Wye 30 10.81 L21-30P No 24 18 6 0 Fuses
CWG-24VYY454A1 Switched POPS Switched POPS CDU, 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 No 24 18 6 0 Breakers
CWG-30VDD458 Switched POPS Switched CDU POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 30 x IEC C13 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P Yes 30 30 0 0 Breakers
CWG-30VDD458C2 Switched POPS Switched CDU, POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P Yes 30 24 6 0 Breakers
CWG-30VDE458 Switched POPS Switched CDU POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 30 x IEC C13 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Delta, 30A w/ NEMA L15-30P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P Yes 30 30 0 0 Breakers
CWG-30VDE458C2 Switched POPS Switched CDU, POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Delta, 30A w/ NEMA L15-30P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P Yes 30 24 6 0 Breakers
CWG-30VYL458 Switched POPS Switched CDU POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 30 x IEC C13 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P Yes 30 30 0 0 Breakers
CWG-30VYL458C2 Switched POPS Switched CDU, POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P Yes 30 24 6 0 Breakers
CWG-30VYM458 Switched POPS Switched CDU POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 30 x IEC C13 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Wye 30 10.81 L21-30P Yes 30 30 0 0 Breakers
CWG-30VYM458C2 Switched POPS Switched CDU, POPS/PIPS (Per Outlet and Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 208V 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10 ft (3 m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Wye 30 10.81 L21-30P Yes 30 24 6 0 Breakers
CWG-48VDD425 Switched POPS Switched POPS CDU, POPS/PIPS, Per Outlet Power Sensing, Per Infeed Power Sensing, 0U, 48 x IEC C13, 3 x LED Amp Meters, Middle Display, 208V 3-Phase Delta, 20A w/ NEMA L15-20P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 20 7.21 L15-30P Yes 48 48 0 0 Breakers
CWG-48VDE425 Switched POPS Switched POPS CDU, POPS/PIPS, Per Outlet Power Sensing, Per Infeed Power Sensing, 0U, 48 x IEC C13, 3 x LED Amp Meters, Middle Display, 208V 3-Phase Delta, 30A w/ NEMA L15-30P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 30 10.81 L15-30P Yes 48 48 0 0 Breakers
CWG-48VYL425 Switched POPS Switched POPS CDU, POPS/PIPS, Per Outlet Power Sensing, Per Infeed Power Sensing, 0U, 48 x IEC C13, 3 x LED Amp Meters, Middle Display, 208V 3-Phase Wye, 20A w/ NEMA L21-20P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 20 7.21 NEMA L21-20P Yes 48 48 0 0 Breakers
CWG-48VYM425 Switched POPS Switched POPS CDU, POPS/PIPS, Per Outlet Power Sensing, Per Infeed Power Sensing, 0U, 48 x IEC C13, 3 x LED Amp Meters, Middle Display, 208V 3-Phase Wye, 30A w/ NEMA L21-30P Connector and Cord, 10ft (3m), Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 30 10.81 NEMA L21-30P Yes 48 48 0 0 Breakers
CWG-8H1A413 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, Circuit Breakers (input power cord ordered separately) Horizontal 120 1 20 2.40 C20 Yes 8 0 0 8 Breakers
CWG-8H2A211 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 208V 20A w/ IEC 60320 C20 Inlet, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection (Input power cord ordered separately) Horizontal 208 1 20 4.16 C20 No 8 8 0 0 Fuses
CWG-8H2C211 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3m (10ft) Cord, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection Horizontal 208 1 30 6.24 L6-30P No 8 8 0 0 Fuses
CWG-8HEA211 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 16A w/ IEC 60320 C20 Inlet, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection (Input power cord ordered separately) Horizontal 230 1 16 3.68 C20 No 8 8 0 0 Fuses
CWG-8HEK211 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord, (2) Temperature/Humidity Sensor Capable, Fuse Branch Circuit Protection Horizontal 230 1 32 7.36 IEC 60309 No 8 8 0 0 Fuses
CW-30VYM354C2-012 Switched Switched CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Top Entry, Fuse Branch Circuit Protection Vertical 208 Wye 30 10.81 NEMA L21-30P No 30 24 6 0 Fuses
CW-32VD2AA15A1 Switched Switched CDU, PIPS - Per Input Power Sensing, 0U, 32 Outlets (24xIEC C13 + 8xIEC C19), LED Amp Meter per Input Feed, Two 208V 20A w/ C20 Inlets, Bottom/Front Entry, 2 x Temp/Humidity Sensor Capable, Circuit Breakers (Power Cords Sold Separately) Vertical 208 1 20 8.30 C20 Yes 32 24 8 0 Breakers
CW-32VD2CA15A1 Switched Switched CDU, PIPS - Per Input Power Sensing, 0U, 32 Outlets (24xIEC C13 + 8xIEC C19), LED Amp Meter per Input Feed, Two 208V 30A w/ NEMA L6-30P Plugs, Bottom/Front Entry, 3m (10ft) Cords, 2 x Temp/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 12.48 L6-30P Yes 32 24 8 0 Breakers
CW-32VDEAA15A1 Switched Switched CDU, PIPS - Per Input Power Sensing, 0U, 32 Outlets (24xIEC C13 + 8xIEC C19), LED Amp Meter per Input Feed, Two 230V 16A w/ C20 Inlets, Bottom/Front Entry, 2 x Temp/Humidity Sensor Capable, Circuit Breakers (Power Cords Sold Separately) Vertical 230 1 16 3.68 C20 Yes 32 24 8 0 Breakers
CW-32VDEKA15A1 Switched Switched CDU, PIPS - Per Input Power Sensing, 0U, 32 Outlets (24xIEC C13 + 8xIEC C19), LED Amp Meter per Input Feed, Two 230V 32A w/ IEC 60309 2P+PE 6Hr Blue Plugs, Bottom/Front Entry, 3m (10ft) Cords, 2 x Temp/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 14.72 2 x IEC 60309 Yes 32 24 8 0 Breakers
CS-36V2QE25D4 Smart Smart Expansion CDU with PIPS (Per Input Power Sensing), 0U, (30) IEC C13 + (6) IEC C19 outlets, LED Amp Meter, 200-240V 1-Phase 60A, IEC 60309 (3-pin Pin/Sleeve) Connector, Bottom/Base Cord Entry, 10 ft (3 m) Cord, Middle LED, Circuit Breaker Protection at the Bottom of the Unit Vertical 208 1 60 12.48 IEC 60309 Yes 36 30 6 0 Breakers
CS-18VD8454A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Input Amp Meters, 208V 3-Phase Delta, 100A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Top/Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 100 36.03 IEC 60309 No 18 0 18 10 Breakers
CS-18VD9454A3 Smart Smart CDU, 0U, 18 x IEC C19 Outlets, 3 x LED Input Amp Meters, 208V 3-Phase Delta, 100A, Unterminated 10ft (3m) Cord, Top/Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 100 36.03 Blunt Cut No 18 0 18 10 Breakers
CW-48VDX458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters, 208V 3-phase Delta, 60A w/ IEC 60309 9hr 4Pin Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.60 IEC 60309 Yes 48 36 12 0 Breakers
CW-48VDV458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters, 208V 3-phase Delta, 50A w/ CS8365C Plug, 10 ft (3 m) Cord, Top Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 48 36 12 0 Breakers
CW-48VYY458A1 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (36xC13 + 12xC19), 3 x LED Amp Meters, 208V 3-phase Wye, 60A w/ IEC 60309 9hr 5Pin Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.60 IEC 60309 Yes 48 36 12 0 Breakers
CWG-24VYY425A9 Switched POPS Switched POPS CDU, PIPS - Per Inlet Power Sensing, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 5Pin Blue Plug, 10ft (3m) Cord, Bottom/Front Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 Yes 24 12 12 0 Breakers
CWG-24VYY425A9 Switched POPS Switched POPS CDU, PIPS - Per Inlet Power Sensing, 0U, 12 x IEC C13 & 12 x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 5Pin Blue Plug, 10ft (3m) Cord, Bottom/Front Power Cord Entry, Middle Display/Network, 2 x Temp/Humidity Capable, Circuit Breakers Vertical 208 Wye 60 21.60 IEC 60309 Yes 24 12 12 0 Breakers
CWG-16V2A317A1 Switched POPS Switched POPS/PIPS CDU, Per Outlet and Per Inlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 208V 20A w/ IEC C20 Inlet (Bottom Entry), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses (Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 Yes 16 12 4 0 Fuses
CWG-16V2C317A1 Switched POPS Switched POPS/PIPS CDU, Per Outlet and Per Inlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 208V 30A w/ NEMA L6-30P Connector and Cord (Bottom Cord Entry), 3m (10ft), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 208 1 30 6.24 L6-30P Yes 16 12 4 0 Fuses
CWG-16VEA317A1 Switched POPS Switched POPS/PIPS CDU, Per Outlet and Per Inlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 230V 16A w/ IEC C20 inlet (Bottom Entry), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses (Power Cord Sold Separately) Vertical 230 1 16 3.68 C20 Yes 16 12 4 0 Fuses
CWG-16VEK317A1 Switched POPS Switched POPS/PIPS CDU, Per Outlet and Per Inlet Power Sensing, 0U, 12 x IEC C13, 4 x IEC C19, 230V 32A w/ IEC 60309 Connector and Cord (Bottom Cord Entry), 3m (10ft), (2) Temperature/Humidity Sensor Capable, w/ Retractable Fuses Vertical 230 1 32 7.36 IEC 60309 Yes 16 12 4 0 Fuses
CS-24H4J484A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 3U, (18) IEC C13 and (6) C19 Outlets, 3 LED Input Amp Meters, 230/400V 16A, 3 m (10 ft) Input Cord w/ IEC 60309 (3P+N+PE) 6hr plug (Front Cord Entry), 20A Circuit Breakers, (2) Temp/Humidity Sensor Capable Horizontal 400 Wye 16 11.04 IEC 60309 Yes 24 18 6 0 Breakers
CS-24H4K484A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 3U, (18) IEC C13 and (6) C19 Outlets, 3 LED Input Amp Meters, 230/400V 32A, 3 m (10 ft) Input Cord w/ IEC 60309 (3P+N+PE) 6hr plug (Front Cord Entry), 20 A Circuit Breakers, (2) Temp/Humidity Sensor Capable Horizontal 400 Wye 32 22.08 IEC 60309 Yes 24 18 6 0 Breakers
CS-24H53484A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 3U, (18) IEC C13 and (6) C19 Outlets, 3 LED Input Amp Meters, 240/415V 20A, 10 ft (3 m) Input Cord w/ IEC 60309 6hr 5pin Plug (Front Cord Entry), 20A Circuit Breakers, 2 x Temp/Humid Capable Horizontal 415 Wye 20 14.40 IEC 60309 Yes 24 18 6 0 Breakers
CS-24H54484A1 Smart Smart CDU, PIPS (Per Input Power Sensing), 3U, (18) IEC C13 and (6) C19 Outlets, 3 LED Input Amp Meters, 240/415V Wye 30A, 10 ft (3 m) Input Cord w/ IEC 60309 6hr 5pin Plug (Front Cord Entry), 20A Circuit Breakers, 2 x Temp/Humid Capable Horizontal 415 Wye 30 21.60 IEC 60309 Yes 24 18 6 0 Breakers
CW-30VDD354C2 Switched Switched CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10ft (3m) Cord Set, Top Entry, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P No 30 24 6 0 Fuses
CW-30VDE354C2 Switched Switched CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 30A w/ NEMA L15-30P Connector, 10ft (3m) Cord Set, Top Entry, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P No 30 24 6 0 Fuses
CW-30VYL354C2 Switched Switched CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, Top Entry, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P No 30 24 6 0 Fuses
CWG-8H1B413 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P Plug, 10 ft (3m) cord, 2 x Temp/Humid Capable, Circuit Breakers Horizontal 120 1 30 3.60 L5-30P Yes 8 0 0 8 Breakers
CWG-24VYM415C9 Switched POPS Switched POPS/PIPS CDU (Per Input and Outlet Power Sensing), 0U, (18) 208V IEC C13, (6) 208V IEC C19, (1) 120V NEMA 5-20R Utility Outlet, (3) LED Amp Meters, 208V 3-Phase Wye, 30A w/ NEMA L21-30P Connector and Cord, 10ft (3m), Bottom/Front Power Cord Entry, 2 x Temp/Humidity Sensor Capable, w/ Circuit Breakers Vertical 208 Wye 30 10.81 L21-30P Yes 24 18 6 1 Breakers
CWG-24VDD415A1 Switched POPS Switched POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Delta, 20A w/ NEMA L15-20P Connector and 10ft (3m) Cord, Bottom/Front Cord Entry, 2 x Temp/Humid Capable, w/ Circuit Breakers Vertical 208 Delta 20 7.21 L15-20P Yes 24 18 6 0 Breakers
CWG-24VDE415A1 Switched POPS Switched POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Delta, 30A w/ NEMA L15-30P Connector and 10ft (3m) Cord, Bottom/Front Cord Entry, 2 x Temp/Humid Capable, w/ Circuit Breakers Vertical 208 Delta 30 10.81 L15-30P Yes 24 18 6 0 Breakers
CWG-24VYL415C9 Switched POPS Switched POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, 18 x IEC C13, 6 x IEC C19, 3 x LED Amp Meters, 208V 3-Phase Wye, 20A w/ NEMA L21-20P Connector and 10ft (3m) Cord, Bottom/Front Cord Entry, 2 x Temp/Humid Capable, w/ Circuit Breakers Vertical 208 Wye 20 7.21 L21-20P Yes 24 18 6 0 Breakers
CS-6H54454B4 Smart Smart CDU, PIPS (Per Input Power Sensing), 2U, 6 x NEMA L6-30R Outlets, 3 LED Input Amp Meters, 240/415V 3-Phase Wye 30A, 10 ft (3 m) Cord, IEC 60309 6Hr, 5-pin, Red Plug, 30 A Circuit Breakers, 2 x Temperature/Humidity Sensor Capable Horizontal 415 Wye 30 21.60 IEC 60309 Yes 6 0 0 0 Breakers
CS-6H5Z454B4 Smart Smart CDU, PIPS (Per Input Power Sensing), 2U, 6 x NEMA L6-30R Outlets, 3 LED Input Amp Meters, 240/415V 3-Phase Wye 30A, 10 ft (3 m) Cord, NEMA L22-30P Plug, 30 A Circuit Breakers, 2 x Temperature/Humidity Sensor Capable Horizontal 415 Wye 30 21.60 L22-30P Yes 6 0 0 0 Breakers
CWG-16H1A454 Switched POPS Switched POPS/PIPS CDU, Per Outlet Power Sensing & Per Inlet Power Sensing, 2U, 16 x NEMA 5-20R Outlets, Input Amp Meter, 120V 20A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 120 1 20 2.40 C20 Yes 16 0 0 16 Breakers
CWG-16H1B454 Switched POPS Switched POPS/PIPS CDU, Per Outlet Power Sensing & Per Inlet Power Sensing, 2U, 16 x NEMA 5-20R Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P, 10' (3m) Front Cord Entry, 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 120 1 30 3.60 C20 Yes 16 0 0 16 Breakers
CW-16H1A454 Switched Switched CDU, 2U, 16 x NEMA 5-20R Outlets, PIPS, LED amp meter, 120V, 20A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable (Input power cord ordered separately) Horizontal 120 1 20 2.40 C20 Yes 16 0 0 16 Fuses
CW-16H1B454 Switched Switched CDU, 2U, 16 x NEMA 5-20R Outlets, LED amp meter, PIPS, 120V, 30A input w/ C20 Inlet, (2) Temperature/Humidity Sensor Capable (Input power cord ordered separately) Horizontal 120 1 30 3.60 C20 Yes 16 0 0 16 Fuses
CSG-48V47425A1 Smart POPS Smart POPS CDU with PIPS (Per Input Power Sensing) Input Current Monitoring, 0U, 48 Outlets (36xC13 + 12xC19), (3) LED Input Current Amp Meters, 230/400V 3-phase Wye, 63A w/ IEC 60309 3P+N+E 6hr Splash-proof Plug, 10 ft (3 m) Cord, Bottom/front Cord Entry, (2) Temperature Humidity Sensor Capable, 10 kAIC Circuit Breaker Branch Circuit Protection, Display and Network Centrally Located Vertical 400 Wye 63 43.47 IEC 60309 Yes 48 36 12 0 Breakers
CSG-48V57425A1 Smart POPS Smart POPS CDU with PIPS (Per Input Power Sensing) Input Current Monitoring, 0U, 48 Outlets (36xC13 + 12xC19), (3) LED Input Current Amp Meters, 240/415V 3-phase Wye, 60A w/ IEC 60309 3P+N+E 6hr Splash-proof Plug, 10 ft (3 m) Cord, Bottom/front Cord Entry, (2) Temperature Humidity Sensor Capable, 10 kAIC Circuit Breaker Branch Circuit Protection, Display and Network Centrally Located Vertical 415 Wye 60 43.20 IEC 60309 Yes 48 36 12 0 Breakers
CW-30V4J458C2 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 30 Outlets (24xC13 + 6xC19), 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A IEC 60309 3P+N+PE 6hr Connector, 10 ft (3 m) Cord, Top Cord Entry, Middle Display and Network Card, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 Yes 30 24 6 0 Breakers
CW-30V4K458C2 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 30 Outlets (24xC13 + 6xC19), 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A IEC 60309 3P+N+PE 6hr Connector, 10 ft (3 m) Cord, Top Cord Entry, Middle Display and Network Card, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 Yes 30 24 6 0 Breakers
CW-30V53458C2 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 30 Outlets (24xC13 + 6xC19), 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A IEC 60309 3P+N+PE 6hr Connector, 10 ft (3 m) Cord, Top Cord Entry, Middle Display and Network Card, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 Yes 30 24 6 0 Breakers
CW-30V54458C2 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 30 Outlets (24xC13 + 6xC19), 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A IEC 60309 3P+N+PE 6hr Connector, 10 ft (3 m) Cord, Top Cord Entry, Middle Display and Network Card, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 Yes 30 24 6 0 Breakers
CW-30V5Z458C2 Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 30 Outlets (24xC13 + 6xC19), 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A NEMA L22-30P Connector, 10 ft (3 m) Cord, Top Cord Entry, Middle Display and Network Card, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P Yes 30 24 6 0 Breakers
CW-24V4J458A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 16A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Top/Top Cord Entry, 10ft (3m) Cord, Circuit Breakers (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 16 11.04 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V4K458A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 230/400V 3-phase, 32A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Top/Top Cord Entry, 10ft (3m) Cord, Circuit Breakers (2) Temperature/Humidity Sensor Capable Vertical 400 Wye 32 22.08 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V53458A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 20A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Top/Top Cord Entry, 10ft (3m) Cord, Circuit Breakers (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 20 14.4 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V54458A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A IEC 60309 3P+N+PE 6hr Connector, Middle Display and Network Access, Top/Top Cord Entry, 10ft (3m) Cord, Circuit Breakers (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 30 21.6 IEC 60309 Yes 24 12 12 0 Breakers
CW-24V5Z458A9 Switched Switched CDU with PIPS (Per Infeed Power Sensing), 0U, 12 x IEC C13 and 12 x IEC C19 Outlets, 3 x LED Amp Meters, 240/415V 3-phase, 30A NEMA L22-30P Connector, Middle Display and Network Access, Top/Top Cord Entry, 10ft (3m) Cord, Circuit Breakers (2) Temperature/Humidity Sensor Capable Vertical 415 Wye 30 21.6 L22-30P Yes 24 12 12 0 Breakers
C-30V2AD21D8 Metered Metered CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 208V 20A, C20 Inlet, Bottom/Front Cord Entry, Middle Display, Doghouse Circuit Breakers (Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 No 30 24 6 0 Breakers
C-30V2CD21D8 Metered Metered CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 208V 30A, NEMA L6-30P Plug, 10'(3m) Cord, Bottom/Front Cord Entry, Middle Display, Doghouse Circuit Breakers Vertical 208 1 30 6.24 L6-30P No 30 24 6 0 Breakers
C-30VEAD21D8 Metered Metered CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 230V 16A, C20 Inlet, Bottom/Front Cord Entry, Middle Display, Doghouse Circuit Breakers (Power Cord Sold Separately) Vertical 230 1 16 3.68 C20 No 30 24 6 0 Breakers
C-30VEKD21D8 Metered Metered CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10'(3m) Cord, Bottom/Front Cord Entry, Middle Display, Doghouse Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 No 30 24 6 0 Breakers
CS-30V2AD25D8 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 208V 20A, C20 Inlet, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Doghouse Circuit Breakers (Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 Yes 30 24 6 0 Breakers
CS-30V2CD25D8 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 208V 30A, NEMA L6-30P Plug, 10 ft (3m) Cord, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Doghouse Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 30 24 6 0 Breakers
CS-30VEAD25D8 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 230V 16A, C20 Inlet, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Doghouse Circuit Breakers (Power Cord Sold Separately) Vertical 230 1 16 3.68 C20 Yes 30 24 6 0 Breakers
CS-30VEKD25D8 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10 ft (3m) Cord, Bottom/Front Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Doghouse Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 30 24 6 0 Breakers
BDL-CXG36VDX-01 Switched POPS Modular PDU includes the following: (2) Switched POPS CDUs, 0U, 24xC13 & 12xC19 Outlets per CDU, 208V 3-Phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plugs, 10'(3m) Bottom Cord Entry, Breakers and (1) Horizontal 1U Modular Controller with dual 3x LED Amp Meters, two Temperature/Humidity Sensor Capable (DIN power cables for Modular Controller Sold Separately) Vertical 208 3 60 21.62 IEC 60309 No 36 24 12 0 Breakers
BDL-CXG36VDV-01 Switched POPS Modular PDU includes the following: (2) Switched POPS CDUs, 0U, 24xC13 & 12xC19 Outlets per CDU, 208V 3-Phase Delta, 50A, CS8365 Plugs, 10'(3m) Bottom Cord Entry, Breakers and (1) Horizontal 1U Modular Controller with dual 3x LED Amp Meters, two Temperature/Humidity Sensor Capable (DIN power cables for Modular Controller Sold Separately) Vertical 208 3 50 18.01 CS8365C No 36 24 12 0 Breakers
BDL-CXG36VYY-01 Switched POPS Modular PDU includes the following: (2) Switched POPS CDUs, 0U, 24xC13 & 12xC19 Outlets per CDU, 208V 3-Phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plugs, 10'(3m) Bottom Cord Entry, Breakers and (1) Horizontal 1U Modular Controller with dual 3x LED Amp Meters, two Temperature/Humidity Sensor Capable (DIN power cables for Modular Controller Sold Separately) Vertical 208 3 60 21.62 IEC 60309 No 36 24 12 0 Breakers
CB-30V2CD01D8 Basic Basic CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 208-240V 30A, NEMA L6-30P Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Doghouse Circuit Breakers Vertical 208 1 30 6.24 L6-30P No 30 24 6 0 Breakers
CB-30VEKD01D8 Basic Basic CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10 ft (3 m) Cord, Bottom/Front Cord Entry, Doghouse Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 No 30 24 6 0 Breakers
CS-54VDX413C6-017 Smart Smart CDU, 0U, 42 x IEC C13 & 12 x IEC C19 Outlets, 6 Branch LED amp meters, 208V 3-Phase Delta, 60A input IEC 60309 9Hr Ground 4-Pin Blue Plug, 10 ft (3 m) Cord, Bottom Entry, Circuit Breakers, (2) Temperature/Humidity Sensor Capable, Optional Cable Retention Bracket Sold Separately Vertical 208 Delta 60 21.62 IEC 60309 No 54 42 12 0 Breakers
CS-54VDV413C6-017 Smart Smart CDU, 0U, 42 x IEC C13 & 12 x IEC C19 Outlets, 6 Branch LED amp meters, 208V 3-phase Delta, 50A input CS8365 plug, 10 ft (3 m) Cord, Bottom Entry, Circuit Breakers, (2) Temperature/Humidity Sensor Capable, Optional Cable Retention Bracket Sold Separately Vertical 208 Delta 50 18.01 CS-8365C No 54 42 12 0 Breakers
CS-54VYY413C6-017 Smart Smart CDU, 0U, 42 x IEC C13 & 12 x IEC C19 Outlets, 6 Branch LED amp meters, 208V 3-phase Wye, 60A input IEC 60309 9Hr Ground 5-Pin Blue Plug, 10 ft (3 m) Cord, Bottom Entry, Circuit Breakers, (2) Temperature/Humidity Sensor Capable, Optional Cable Retention Bracket Sold Separately Vertical 208 Wye 60 18.01 IEC 60309 No 54 42 12 0 Breakers
CB-12V2AH01 Basic Basic CDU, 0U, 12 x IEC C13 Outlets, 208-240V 16/20A, C20 Inlet, Bottom/Front Cord Entry, Circuit Breakers (Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 No 12 12 0 0 Breakers
CB-12V2CH01 Basic Basic CDU, 0U, 12 x IEC C13 Outlets, 208-240V 30A,NEMA L6-30P Plug, 10'(3m) Cord, Bottom/Front Cord Entry, Circuit Breakers Vertical 208 1 30 6.24 L6-30P No 12 12 0 0 Breakers
CS-24V2C458C1 Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter, 208V 30A,NEMA L6-30P Cordset 10ft(3m), Top Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 24 18 6 0 Breakers
CS-24VYL11 Smart Smart CDU, 0U, 21 x IEC C13 Outlets, 3 x LED amp meters, 3 Phase Wye 208V input w/ L21-20P connector & cord, 10ft (3m), (2) Temperature/Humidity Sensor Capable, no branch circuit protection, black Vertical 208 Wye 20 7.21 L21-20P No 21 21 0 0 None
C-21VDD111 Metered Metered CDU, 0U, 21 x IEC C13 outlets, 3 x LED amp Meters, 3-Phase Delta input w/ L15-20P connector & cord, 10ft (3m), no branch circuit protection, black Vertical 208 Delta 20 7.21 L15-20P No 21 21 0 0 None
C-21VYL111 Metered Metered CDU, 0U, 21 x IEC C13 outlets, 3 x LED amp Meters, 3-Phase Wye input w/ L21-20P connector & cord, 10ft (3m), no branch circuit protection, black Vertical 208 Wye 20 7.21 L21-20P No 21 21 0 0 None
CWG-24V2A458 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 24 x IEC C13, LED Amp Meter, 208-240V 20A w/ Input w/ IEC C20 Inlet, Top Cord Entry, Middle Display, 3m (10ft) Cord, 2 x Temp/Humid Capable, Circuit Breakers (Inlet Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 Yes 24 24 0 0 Breakers
CWG-24V2C458 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 24 x IEC C13, LED Amp Meter, 208-240V 30A w/ NEMA L6-30P Connector, Top Cord Entry, Middle Display, 3m (10ft) Cord, 2 x Temp/Humid Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 24 24 0 0 Breakers
CWG-24VEA458 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 24 x IEC C13, LED Amp Meter, 230V 16A w/ Input w/ IEC C20 Inlet, Top Cord Entry, Middle Display, 3m (10ft) Cord, 2 x Temp/Humid Capable, Circuit Breakers (Inlet Power Cord Sold Separately) Vertical 230 1 16 3.68 C20 Yes 24 24 0 0 Breakers
CWG-24VEK458 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 24 x IEC C13, LED Amp Meter, 230V 32A w/ IEC 60309 2P+PE 6Hr Blue Plug, Top Cord Entry, Middle Display, 3m (10ft) Cord, 2 x Temp/Humid Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 24 24 0 0 Breakers
CW-16H2A454 Switched Switched CDU, Per Input Power Sensing 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V 20A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 208 1 20 4.16 C20 Yes 16 16 0 0 Breakers
CW-16H2C454 Switched Switched CDU, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V 30A w/ NEMA L6-30P Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable Horizontal 208 1 30 6.24 L6-30P Yes 16 16 0 0 Breakers
CW-16HEA454 Switched Switched CDU, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 16A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, (2) Temperature/Humidity Sensor Capable (Input power cord sold separately) Horizontal 230 1 16 3.68 C20 Yes 16 16 0 0 Breakers
CW-16HEK454 Switched Switched CDU, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord (Front Cord Entry), (2) Temperature/Humidity Sensor Capable, 20 A Circuit Breakers Horizontal 230 1 32 7.36 IEC 60309 Yes 16 16 0 0 Breakers
STV-4302D Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Delta, 20A w/ NEMA L15-20P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Delta 20 7.21 L15-20P Yes 48 48 0 0 Breakers
STV-4302E Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Delta, 30A w/ NEMA L15-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Delta 30 10.81 L15-30P Yes 48 48 0 0 Breakers
STV-4302L Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Wye, 20A w/ NEMA L21-20P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Wye 20 7.21 L21-20P Yes 48 48 0 0 Breakers
STV-4302M Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 3 Phase Wye, 30A w/ NEMA L21-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Wye 30 10.81 L21-30P Yes 48 48 0 0 Breakers
STV-4301A Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, LED Amp Meter, 208V, 20A w/ IEC C20 Inlet (Top Entry), Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets (Power Cord Sold Separately) Vertical 208 1 20 4.16 C20 Yes 48 48 0 0 Breakers
STV-4301C Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, LED Amp Meter, 208V, 30A w/ NEMA L6-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 1 30 6.24 L6-30P Yes 48 48 0 0 Breakers
STV-4301D Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, LED Amp Meter, 230V, 16A w/ IEC C20 Inlet (Top Entry), Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets (Power Cord Sold Separately) Vertical 230 1 16 3.68 C20 Yes 48 48 0 0 Breakers
STV-4301K Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, LED Amp Meter, 230V, 32A w/ IEC 60309 Plug, 3 m (10 ft) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 230 1 32 7.36 IEC 60309 Yes 48 48 0 0 Breakers
CW-8H1A413 Switched Switched CDU, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, Circuit Breakers (input power cord ordered separately) Horizontal 120 1 20 2.40 C20 Yes 8 0 0 8 Breakers
CW-8H1B413 Switched Switched CDU, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 30A w/ NEMA L5-30P Plug, 10 ft (3m) cord, 2 x Temp/Humid Capable, Circuit Breakers Horizontal 120 1 30 3.60 L5-30P Yes 8 0 0 8 Breakers
CW-8H1A113 Switched Switched CDU, PIPS (Per Inlet Power Sensing), 1U, 8 x NEMA 5-20P Outlets, Input Amp Meter, 120V 20A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, No Branch Circuit Protection (input power cord ordered separately) Horizontal 120 1 20 2.40 C20 Yes 8 0 0 8 None
CW-24V1A325 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x NEMA 5-20R Outlets, (1) Input LED Amp Meter in the middle of the unit, 120V 20A IEC C20 Inlet, Bottom/Front Cord Entry, (2) Temp/Humidity Sensor Capable, Fuses (Power Cord Sold Separately) Vertical 120 1 20 2.4 C20 Yes 24 0 0 24 Fuses
CW-24V1B325 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x NEMA 5-20R Outlets, (1) Input LED Amp Meter in the middle of the unit, 120V 30A Input w/ NEMA L5-30P Plug, Bottom/Front Cord Entry, 10ft (3M) Cord, (2) Temp/Humidity Sensor Capable, Fuses Vertical 120 1 30 3.6 L5-30P Yes 24 0 0 24 Fuses
CW-24V2A325 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, (1) Input LED Amp Meter in the middle of the unit, 208V 20A Input w/ IEC 60320 C20 Inlet (Power Cord Sold Separately), Bottom/Front Cord Entry, Retractable Fuses, (2) Temperature/Humidity Sensor Capable Vertical 208 1 20 4.16 C20 Yes 24 24 0 0 Fuses
CW-24V2C325 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, (1) Input LED Amp Meter in the middle of the unit, 208V 30A Input w/ NEMA L6-30P Plug, Bottom/Front Cord Entry, 10ft (3M) Cord, (2) Temp/Humidity Capable, Fuses Vertical 208 1 30 6.24 L6-30P Yes 24 24 0 0 Fuses
CW-24VEA325 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, (1) Input LED Amp Meter in the middle of the unit, 230V 16A Input w/ IEC 60320 C20 Inlet (Power Cord Sold Separately), Bottom/Front Cord Entry, Retractable Fuses, (2) Temperature/Humidity Sensor Capable Vertical 230 1 16 3.68 C20 Yes 24 24 0 0 Fuses
CW-24VEK325 Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, (1) Input LED Amp Meter in the middle of the unit, 230V 32A Input w/ IEC 60309 2P+PE 6Hr Blue Plug, Bottom/Front Cord Entry, 10ft (3M) Cord, (2) Temp/Humidity Capable, Fuses Vertical 230 1 32 7.36 IEC 60309 Yes 24 24 0 0 Fuses
STV-4303J Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A w/ IEC 60309 (3P+N+PE) 6hr Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, 10KAIC Circuit Breakers to side of outlets Vertical 400 Wye 16 11.04 IEC 60309 Yes 48 48 0 0 Breakers
STV-4303K Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A w/ IEC 60309 (3P+N+PE) 6hr Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, 10KAIC Circuit Breakers to side of outlets Vertical 400 Wye 32 22.08 IEC 60309 Yes 48 48 0 0 Breakers
STV-4303C Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A w/ IEC 60309 (3P+N+PE) 6hr Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, 10KAIC Circuit Breakers to side of outlets Vertical 415 Wye 20 14.4 IEC 60309 Yes 48 48 0 0 Breakers
STV-4303D Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ IEC 60309 (3P+N+PE) 6hr Red Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, 10KAIC Circuit Breakers to side of outlets Vertical 415 Wye 30 21.6 IEC 60309 Yes 48 48 0 0 Breakers
STV-4303Z Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ NEMA L22-30P Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, 10KAIC Circuit Breakers to side of outlets Vertical 415 Wye 30 21.6 L22-30P Yes 48 48 0 0 Breakers
CWG-24V1A425 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 24 x NEMA 5-20R, LED Amp Meter, 120V 20A w/ IEC C20 Inlet, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, Middle Display and Network, Circuit Breakers Branch Circuit Protection, (power cord sold separately) Vertical 120 1 20 2.40 C20 Yes 24 0 0 24 Breakers
CWG-24V1B425 Switched POPS Switched POPS CDU, Per Outlet Power Sensing, PIPS - Per Input Power Sensing, 0U, 24 x NEMA 5-20R, LED Amp Meter, 120V 30A w/ NEMA L5-30P, 10' (3m) Cord, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, Middle Display and Network, Circuit Breakers Branch Circuit Protection Vertical 120 1 30 3.60 L5-30P Yes 24 0 0 24 Breakers
C42VY-4NAF21C4 Metered Metered CDU, 0U, (36) IEC C13 and (6) IEC C19 Alternating Phase Outlets, 3 x LED amp meters, 230/400V 3 Phase Wye 16A input w/ IEC 60309 6hr 5pin Red Plug, Bottom/Front Cord Entry, 10ft (3m), 10KAIC Doghouse Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 Yes 42 36 6 0 Breakers
C42VY-4PAF21C4 Metered Metered CDU, 0U, (36) IEC C13 and (6) IEC C19 Alternating Phase Outlets, 3 x LED amp meters, 230/400V 3 Phase Wye 32A input w/ IEC 60309 6hr 5pin Red Plug, Bottom/Front Cord Entry, 10ft (3m), 10KAIC Doghouse Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 Yes 42 36 6 0 Breakers
C42VY-5NAF21C4 Metered Metered CDU, 0U, (36) IEC C13 and (6) IEC C19 Alternating Phase Outlets, 3 x LED amp meters, 240/415V 3 Phase Wye 20A input w/ IEC 60309 6hr 5pin Red Plug, Bottom/Front Cord Entry, 10ft (3m), 10KAIC Doghouse Circuit Breakers Vertical 415 Wye 20 14.4 IEC 60309 Yes 42 36 6 0 Breakers
C42VY-5PAF21C4 Metered Metered CDU, 0U, (36) IEC C13 and (6) IEC C19 Alternating Phase Outlets, 3 x LED amp meters, 240/415V 3 Phase Wye 30A input w/ IEC 60309 6hr 5pin Red Plug, Bottom/Front Cord Entry, 10ft (3m), 10KAIC Doghouse Circuit Breakers Vertical 415 Wye 30 21.6 IEC 60309 Yes 42 36 6 0 Breakers
C42VY-5CAF21C4 Metered Metered CDU, 0U, (36) IEC C13 and (6) IEC C19 Alternating Phase Outlets, 3 x LED amp meters, 240/415V 3 Phase Wye 30A input w/ NEMA L22-30P Plug, Bottom/Front Cord Entry, 10ft (3m), 10KAIC Doghouse Circuit Breakers Vertical 415 Wye 30 21.6 L22-30P Yes 42 36 6 0 Breakers
STV-1001C Basic Basic CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 208-240V 30A, NEMA L6-30P Plug, 10 ft (3 m) w/ Power Pivot Cord Entry, Circuit Breakers Vertical 208 1 30 6.24 L6-30P No 30 24 6 0 Breakers
STV-1001K Basic Basic CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10 ft (3 m) w/ Power Pivot Cord Entry, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 No 30 24 6 0 Breakers
STV-2001C Metered Metered CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter w/ Auto-flip, 208-240V 30A, NEMA L6-30P Plug, 10'(3m) Cord w/ Power Pivot Cord Entry, Middle Display, Circuit Breakers Vertical 208 1 30 6.24 L6-30P No 30 24 6 0 Breakers
STV-2001K Metered Metered CDU, 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter w/ Auto-flip, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10'(3m) Cord, w/ Power Pivot Cord Entry, Middle Display, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 No 30 24 6 0 Breakers
STV-3101C Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter w/ Auto-flip, 208-240V 30A, NEMA L6-30P Plug, 10 ft (3m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 30 24 6 0 Breakers
STV-3101K Smart Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter w/ Auto-flip, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10 ft (3m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 30 24 6 0 Breakers
SEV-3101C Smart Smart CDU (Expansion Unit), PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter w/ Auto-flip, 208-240V 30A, NEMA L6-30P Plug, 10 ft (3m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 30 24 6 0 Breakers
SEV-3101K Smart Smart CDU (Expansion Unit), PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 & 6 x IEC C19 Outlets, 1 x LED Amp Meter w/ Auto-flip, 230V 32A, IEC 60309 6hr 3 Pin Blue Plug, 10 ft (3m) Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 30 24 6 0 Breakers
STV-4102C Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 208-240V 30A Input w/ NEMA L6-30P Plug, 3m (10') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 208 1 30 6.24 L6-30P Yes 24 24 0 0 Breakers
STV-4102K Switched Switched CDU with PIPS (Per Input Power Sensing), 0U, 24 x IEC C13 Outlets, (1) Input LED Amp Meter w/ Auto-flip, 230V 32A Input w/ IEC 60309 6hr 3 Pin Blue Plug, 3m (10') Cord w/ Power Pivot Cord Entry, Middle Display/Network, (2) Temp/Humidity Sensor Capable, Circuit Breakers Vertical 230 1 32 7.36 IEC 60309 Yes 24 24 0 0 Breakers
C-43V53454-026 Metered *** Contact Sales for more info *** Metered CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 No 43 43 0 0 Breakers
C-43V54454-026 Metered *** Contact Sales for more info ***Metered CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 No 43 43 0 0 Breakers
C-43V5Z454-026 Metered *** Contact Sales for more info ***Metered CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ NEMA L22-30P Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P No 43 43 0 0 Breakers
C-43V4J454-026 Metered *** Contact Sales for more info ***Metered CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 No 43 43 0 0 Breakers
C-43V4K454-026 Metered *** Contact Sales for more info ***Metered CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 No 43 43 0 0 Breakers
CS-43V53454-026 Smart *** Contact Sales for more info ***Smart CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 No 43 43 0 0 Breakers
CS-43V54454-026 Smart *** Contact Sales for more info ***Smart CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 415 Wye 30 21.60 2 x IEC 60309 No 43 43 0 0 Breakers
CS-43V5Z454-026 Smart *** Contact Sales for more info ***Smart CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ NEMA L22-30P Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P No 43 43 0 0 Breakers
CS-43V4J454-026 Smart *** Contact Sales for more info ***Smart CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 No 43 43 0 0 Breakers
CS-43V4K454-026 Smart *** Contact Sales for more info ***Smart CDU, 0U, 43xC13 Outlets, 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 No 43 43 0 0 Breakers
CWS-43V53454-026 Switched *** Contact Sales for more info ***Switched CDU, 0U, 43xC13 Outlets (40xSwitched & 3x Always On), 3 x LED Amp Meters, 240/415V 3-phase Wye, 20A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 415 Wye 20 14.40 IEC 60309 No 43 0 0 0 Breakers
CWS-43V54454-026 Switched *** Contact Sales for more info ***Switched CDU, 0U, 43xC13 Outlets (40xSwitched & 3x Always On), 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 415 Wye 30 21.60 IEC 60309 No 43 43 0 0 Breakers
CWS-43V5Z454-026 Switched *** Contact Sales for more info ***Switched CDU, 0U, 43xC13 Outlets (40xSwitched & 3x Always On), 3 x LED Amp Meters, 240/415V 3-phase Wye, 30A w/ NEMA L22-30P Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 415 Wye 30 21.60 L22-30P No 43 0 0 0 Breakers
CWS-43V4J454-026 Switched *** Contact Sales for more info ***Switched CDU, 0U, 43xC13 Outlets (40xSwitched & 3x Always On), 3 x LED Amp Meters, 230/400V 3-phase Wye, 16A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 400 Wye 16 11.04 IEC 60309 No 43 43 0 0 Breakers
CWS-43V4K454-026 Switched *** Contact Sales for more info ***Switched CDU, 0U, 43xC13 Outlets (40xSwitched & 3x Always On), 3 x LED Amp Meters, 230/400V 3-phase Wye, 32A w/ IEC 60309 Plug, 10 ft (3 m) Cord, Top/Top Cord Entry, 2 x Temp/Humid Capable, Circuit Breakers Vertical 400 Wye 32 22.08 IEC 60309 No 43 43 0 0 Breakers
CB-12H1-C20 Basic Basic CDU, 12 NEMA 5-20R outlets, 120V w/ C20 Inlet (Input power cord ordered separately) Horizontal 120 1 20 2.40 C20 No 12 0 0 12 None
CSG-24VDD425A1 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, (18) IEC C13 + (6) IEC C19, (3) LED Amp Meters, Middle Display/Network, 208V 3-phase Delta, 20A w/ NEMA L15-20P Connector and 10ft (3m) Cord, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 20 7.21 L15-20P Yes 24 18 6 0 Breakers
CSG-24VDE425A1 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, (18) IEC C13 + (6) IEC C19, (3) LED Amp Meters, Middle Display/Network, 208V 3-phase Delta, 30A w/ NEMA L15-30P Connector and 10ft (3m) Cord, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 30 10.81 L15-30P Yes 24 18 6 0 Breakers
CSG-24VYL425C9 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, (18) IEC C13, (6) IEC C19 and (1) NEMA 5-20R Accessories Outlets, (3) LED Amp Meters, Middle Display/Network, 208V 3-phase Wye, 20A w/ NEMA L21-20P Connector and 10ft (3m) Cord, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 20 7.21 L21-20P Yes 24 18 6 0 Breakers
CSG-24VYM425C9 Smart POPS Smart POPS (Per Outlet Power Sensing) CDU with PIPS (Per Inlet Power Sensing), 0U, (18) IEC C13, (6) IEC C19 and (1) NEMA 5-20R Accessories Outlets, (3) LED Amp Meters, Middle Display/Network, 208V 3-phase Wye, 30A w/ NEMA L21-30P Connector and 10ft (3m) Cord, Bottom/Front Entry, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 30 10.81 L21-30P Yes 24 18 6 0 Breakers
STV-4103V Switched Switched CDU with PIPS, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 24 24 0 0 Breakers
STV-4103D Switched Switched CDU with PIPS, 0U, 24 x IEC C13 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 Yes 24 24 0 0 Breakers
STV-4103Y Switched Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48x IEC C13 Outlets, LED Amp Meter, 230V, 16A w/ IEC C20 Inlet (Top Entry), Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets (Power Cord Sold Separately) Vertical 208 Wye 60 21.62 IEC 60309 Yes 24 24 0 0 Breakers
STV-4104V Switched Switched CDU with PIPS, 0U, 18xIEC C13 and 6x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 50A, CS8365C Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 50 18.01 CS8365C Yes 24 18 6 0 Breakers
STV-4104D Switched Switched CDU with PIPS, 0U, 18xIEC C13 and 6x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Delta, 60A, IEC 60309 9hr 4 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Delta 60 21.62 IEC 60309 Yes 24 18 6 0 Breakers
STV-4104Y Switched Switched CDU with PIPS, 0U, 18xIEC C13 and 6x IEC C19 Outlets, 3 x LED Amp Meters, 208V 3-phase Wye, 60A, IEC 60309 9hr 5 Pin Blue Plug, 10ft (3m) Cord, Top Power Cord Entry, Middle Display/Network, (2) Temperature/Humidity Sensor Capable, Circuit Breakers Vertical 208 Wye 60 21.62 IEC 60309 Yes 24 18 6 0 Breakers
CS-30VDD354C2 Smart *** Contact Sales for more info *** Smart CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10ft (3m) Cord Set, Top Entry, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P No 30 24 6 0 Fuses
CS-30VDE354C2 Smart *** Contact Sales for more info *** Smart CDU, PIPS (Per Input Power Sensing), 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 30A w/ NEMA L15-30P Connector, 10ft (3m) Cord Set, Top Entry, (2) Temperature/Humidity Sensor Capable, Breaker Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P No 30 24 6 0 Fuses
CS-30VYL354C2 Smart *** Contact Sales for more info *** Smart CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, Top Entry, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P No 30 24 6 0 Fuses
CS-30VYM354C2 Smart *** Contact Sales for more info *** Smart CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Top Entry, Fuse Branch Circuit Protection Vertical 208 Wye 30 10.81 L21-30P No 30 24 6 0 Fuses
C-30VDD354C2 Metered *** Contact Sales for more info *** Metered CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 20A w/ NEMA L15-20P Connector, 10ft (3m) Cord Set, Top Entry, Fuse Branch Circuit Protection Vertical 208 Delta 20 7.21 L15-20P No 30 24 6 0 Fuses
C-30VDE354C2 Metered *** Contact Sales for more info *** Metered CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Delta, 30A w/ NEMA L15-30P Connector, 10ft (3m) Cord Set, Top Entry, Fuse Branch Circuit Protection Vertical 208 Delta 30 10.81 L15-30P No 30 24 6 0 Fuses
C-30VYL354C2 Metered *** Contact Sales for more info *** Metered CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 20A w/ NEMA L21-20P Connector, 10ft (3m) Cord Set, Top Entry, Fuse Branch Circuit Protection Vertical 208 Wye 20 7.21 L21-20P No 30 24 6 0 Fuses
C-30VYM354C2 Metered *** Contact Sales for more info *** Metered CDU, 0U, 24 x IEC C13, 6 x IEC C19 Outlets, 3 x LED Amp Meters in Middle of CDU, 3-phase Wye, 30A w/ NEMA L21-30P Connector, 10ft (3m) Cord Set, Top Entry, Fuse Branch Circuit Protection Vertical 208 Wye 30 10.81 L21-30P No 30 24 6 0 Fuses
STV-6301V Switched POPS Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (42xC13 + 6xC19) and POPS (Per Outlet Power Sensing), (3) Input Current LED Amp Meters, 208 3-phase Delta, 50 w/ CS8365 Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Delta 50 18.01 CS8365C Yes 48 42 6 0 Breakers
STV-6301D Switched POPS Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (42xC13 + 6xC19) and POPS (Per Outlet Power Sensing), (3) Input Current LED Amp Meters, 208 3-phase Delta, 60 w/ IEC 60309 (3P+PE) 9hr Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Delta 60 21.62 IEC 60309 Yes 48 42 6 0 Breakers
STV-6301Y Switched POPS Switched CDU with PIPS (Per Inlet Power Sensing), 0U, 48 Outlets (42xC13 + 6xC19) and POPS (Per Outlet Power Sensing), (3) Input Current LED Amp Meters, 208 3-phase Wye, 60 w/ IEC 60309 (3P+N+PE) 9hr Blue Plug, 10 ft (3 m) Cord, Top Cord Entry, Middle Display to side of outlets, (2) Temperature/Humidity Sensor Capable, Circuit Breakers to side of outlets Vertical 208 Wye 60 21.62 IEC 60309 Yes 48 42 6 0 Breakers